User Guide

4-24 Configuring Your Server
Option Parameter Description Your Setting
Power on Delay
Time
[0] - 255 Specify the DC power on delay
time within the range between 0
and 255 seconds. The time
specified is valid when "Power On"
or "Last State" is specified for AC
LINK.
Platform Event
Filtering
Disabled
[Enabled]
This item becomes meaningless
when the notification feature of
EXPRESSSCOPE Engine is
enabled.
[ ]: Factory-set
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off Last State Power On
Operating Off On On
Aborting (DC power being off also) Off Off On
Forced shutdown Off Off On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.
IMPORTANT:
To power on the server from the UPS (Uninterruptible Power
Supply), select [Server] - [AC Link] - [Power On].
If the server is connected to the UPS, set at least 10 seconds delay in
the power-on schedule.