Planning Guide
System Specifications
System Specifications A-5
Table A-1. Pedestal System Specifications
Power
Input power A-side enclosure: 650W
B-side enclosure: 650W
Nominal input voltage (AC) 100-230 volts +/- 10% 240V + 6%/-10%; 50/60 Hz
Protective earth ground current 3.5 milliamperes maximum for each AC power cord
Physical Dimensions of System in a Pedestal Case
Height 23.25 in. (59.05 cm.)
Width 8.62 in. (21.89 cm); 12.88 in. (32.72 cm)
Depth 31.38 in. (79.71 cm)
Weight, including 8 DIMMS, 4
processors, and 6 disks
Two enclosures: 110 lb (49.9 kg), fully loaded
Case: 68 lb (30.84 kg)
Environmental
Operating temperature 41
°F to 95°F (5°C to 35°C)
For every 800 ft (243.8m) above 2,000 ft (609.6m),
lower the maximum operating temperature (35°C) by
1
°C.
Storage temperature -38
° F to 140° F (-40° C to 60° C)
Operating altitude 0 ft to 10,000 ft (0m to 3,048m)
Maximum rate of temperature
change during operation
18°F/hr (10
°C/hr) or
0.30°F/min (0.17°C/min)
Relative humidity during
operation
20% to 80% (noncondensing)
Relative humidity during storage 8% to 80%
Heat dissipation 4432 BTUs per hour