User's Guide
Problem Solving 5-19
STATUS LED
Error Message
Color State
Suspected module Description Procedure
Cor1 offline
Green Blink PCI module #2 PCI module logically isolated
Start the PCI module by ft sever
utility or dismount and remount
that module. If not solved by the
above, contact your sales agent.
Cor1 removed
Green Blink PCI module #2 PCI module detached Dismount and remount the PCI
module. If not solved by the
above, contact your sales agent.
Cor1 Temp Alm 00
Amber Blink PCI module #2 Temperature alarm (lower limit)
Cor1 Temp Alm 02
Amber Lit PCI module #2 Fatal temperature alarm (lower
limit)
Cor1 Temp Alm 07
Amber Blink PCI module #2 Temperature alarm (upper limit)
Cor1 Temp Alm 09
Amber Lit PCI module #2 Fatal temperature alarm (upper
limit)
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.
CPU IERR 00
Green Blink CPU module #1 CPU#1 internal error
CPU IERR 01
Green Blink CPU module #1 CPU#2 internal error
CPU IERR 20
Green Blink CPU module #2 CPU#1 internal error
CPU IERR 21
Green Blink CPU module #2 CPU#2 internal error
CPU T-Trip 00
Green Blink CPU module #1 CPU#1 thermal change error
(upper limit)
CPU T-Trip 01
Green Blink CPU module #1 CPU#2 thermal change error
(upper limit)
CPU T-Trip 20
Green Blink CPU module #2 CPU#1 thermal change error
(upper limit)
CPU T-Trip 21
Green Blink CPU module #2 CPU#2 thermal change error
(upper limit)
CPU0 +12ss Alm
00
Amber Blink CPU module #1
+12-V power voltage alarm (lower
limit)
CPU0 +12ss Alm
02
Amber Lit CPU module #1 Fatal +12-V power voltage alarm
(lower limit)
CPU0 +12ss Alm
07
Amber Blink CPU module #1 +12-V power voltage alarm (upper
limit)
CPU0 +12ss Alm
09
Amber Lit CPU module #1 Fatal +12-V power voltage alarm
(upper limit)
CPU0 +12v Alm 00
Amber Blink CPU module #1 12-V power voltage alarm (lower
limit)
CPU0 +12v Alm 02
Amber Lit CPU module #1
Fatal 12-V power voltage alarm
(lower limit)
CPU0 +12v Alm 07
Amber Blink CPU module #1 12-V power voltage alarm (upper
limit)
CPU0 +12v Alm 09
Amber Lit CPU module #1 Fatal 12-V power voltage alarm
(upper limit)
CPU0 +1.5v Alm
00
Amber Blink CPU module #1 1.5-V power voltage alarm (lower
limit)
CPU0 +1.5v Alm
02
Amber Lit CPU module #1 Fatal 1.5-V power voltage alarm
(lower limit)
Contact your sales agent.