Installation & Configuration Guide

112
Sets the wait time for waiting until the service stops completely. The range that
can be specified is from 0 to 3600 seconds. If 0 is specified, the wait time is
unlimited. This parameter can be omitted. If it is omitted, the wait time is 40
seconds. Also, this parameter cannot be specified at the same time as the /C
parameter.
As an example, the following section explains the steps required to customize the
scripts for monitoring an arbitrary service (e.g. Telnet service).
Prerequisites
Please verify that the service you would like to monitor (in this case Telnet
service) starts and stops normally using Control Panel -> Administrative tools ->
Services. If the Telnet service has started, please stop it using Control Panel ->
Administrative tools -> Services
Customization Steps
Step 1:
Right Click on the Fail over Group in the ExpressCluster Manager UI and select
the Property(P) menu item.
The Screen shot is as shown: