Printer User Manual
Table Of Contents
- magicolor 6110 User’s Guide
- Contents
- Replacing Consumables
- Using Media
- Maintaining the Printer
- Troubleshooting
- Installing Other Accessories
- Introduction
- Antistatic Protection
- BuzzBox
- Cabinet
- Color Calibration Kit
- Dual In-Line Memory Modules (DIMMs)
- Duplex Unit
- Emulations, Fonts, and Other Software
- Lower Feeder Unit (LFU)
- Interfaces and Daughterboards
- SCSI Interface
- Internal IDE Hard Disk Drive
- SC-210 Color Convenience Copier
- Security Key
- Time-of-Day Clock
- Color Printing
- Repacking the Printer
- Technical Specifications
- Requirements
- Engine and Controller Specifications
- Print Media
- Document Option Commands
- Supported DOCs
- Header/Trailer Page Commands
- HP-GL Emulation Commands
- HP PCL 5e Emulation Commands
- Lineprinter Emulation Commands
- PostScript Emulation Command
- CCITT Groups 3 and 4 Commands
- Document Formatting
- Job and Subjob Boundary Commands
- LN03 Plus Commands (Optional Emulation Required)
- CALS Commands (Optional Emulation Required)
- TIFF Commands (Optional Emulation Required)
- Menu Chart Conventions
- Index

Engine and Controller Specifications190
Current
Environmental
Mode Average Maximum
Operation
Standby
Power saver mode
5 amperes
1.7 amperes
11 amperes
11 amperes
0.40 amp-
eres
Noise level Printing:
Less than 55 dB (A)
Standby:
Less than 41 dB (A)
Relative
humidity
Operating:
20-80% RH (noncondensing)
Transportation/Storage:
10–90% RH (non-
condensing)
Temperature
range
Operating:
50-90.5° F (10-32.5° C)
Transportation/Storage:
32-95° F (0-35° C)
Altitude Operating:
0-8202 ft (0-2500 m)
Inclination Operating:
1.5° or less slant at any point around the
machine
80
60
40
70
50
30
20
0
10
10
20
30
17.5
27
32.5
Optimal Operating Range
Acceptable Operating Range
Ambient Humidity (%RH)
50
63.5
68
80.6
86
95.0
Cº
Fº
Ambient Temperature