Operation Guide

- 137 -
IMPORTANT: Executing the "apply" command reboots the EM card.
If two EM cards are installed, both cards are rebooted. While rebooting,
the bridge and SNMP functions are stopped. Accordingly, the
connection via the management LAN of CPU blades and switch
modules is temporarily disconnected. In addition, system monitoring by
NEC ESMPRO Manager is temporarily disabled. If a timeout error
occurs, reconnect after the active EM card has rebooted.
NOTE: When two EM cards cards are installed, check if the standby
EM card works normally. If the standby EM card is activated or faulty,
the "apply" command cannot be executed.
Wait for a moment until the standby EM card becomes ready.
If the standby EM card is faulty, remove it before executing the "apply"
command.
When you click the [Reset] button, the current settings are displayed.