User Guide

155
Command name
ASSIGN
First argument
"SERVER" | "SWITCH"
Second argument
<Slot number> | <Slot number> - <Slot number> | <Slot number> , <Slot number> | "ALL"
When <Slot number> and <Slot number> are concatenated by '-' (hyphen) or ',' (comma), insert a space
before and after '-' (hyphen) or ',' (comma).
Slot number:
For CPU blades, slot number means the CPU blade number.
Also for switch modules, slot number means the module number.
Third argument
< Registered user's name >
Example of execution
1Z34AB7890(Administrator)> assign server 1 test
test has been granted access to the valid requested bay(s)
1Z34AB7890(Administrator)>
Example of execution of the command for user assignment (for CPU blade/switch module)
Default value
Supplementary information
Only users with the ADMINISTRATOR right can use this command.
Assigning a user (for EM card)
Overview
Configures access permission to the EM cards for the specified user.
Command name
ASSIGN
First argument
"EM"
Second argument
<Registered user's name >
Example of execution
1Z34AB7890(Administrator)> assign em test
test has been granted access to the EM.
1Z34AB7890(Administrator)>
Example of execution of the command for user assignment (for EM card)
Default value
Supplementary information
Only users with the ADMINISTRATOR right can use this command.