User Guide
196
Default value
Supplementary information
About Diagnostic Status
Internal Data Shows FRU information validity. OK: valid, Failed: invalid (checksum error, etc.)
Device Failure Shows device failure status. OK: Normal operation, Failed: Failure, Not Performed:
no checking is performed.
AC Cord Shows AC cable connection status. OK: Normal, Failed: failure
About the status of power saving
Current Power Output "0 Watts (POWER SAVING)": Turns off the power unit by power saving function.
Displaying the blade enclosure status
Overview
Displays the status of the blade enclosure.
Information to be displayed
Operational status
ID LED status
Power status and capacity
Command name
SHOW ENCLOSURE STATUS
Argument
None
Example of execution
1Z34AB7890(Administrator)> show enclosure status
Enclosure:
Status : OK
ID LED : Off
Diagnostic Status:
Internal Data OK
Enclosure Manager:
Status: OK
Power Subsystem:
Status : OK
Redundancy : Power Supply Redundant
Total Capacity : 9000 Watts
Redundant Capacity : 2250 Watts
InputPower : 782 VA
Cooling Subsystem:
Status : OK
1Z34AB7890(Administrator)>