User guide

101
Rack settings (EM card)
1. Confirm that the EM card is powered on.
2. Confirm that you have logged in as Administrator or a user whose access right is
ADMINISTRATOR or OPERATOR from a CLI of the EM serial console or EM console. If
you have not, log in as "Administrator" or a user whose access right is ADMINISTRATOR or
OPERATOR.
3. Configure the following information about the rack by running commands from the CLI. For
details, refer to "Commands."
Rack name (required for report processing)
Configure the name of the rack on which the EM card is installed (up to 32 characters).
Specify any unique name to identify the rack.
SET RACK NAME <rack name>
― Rack ID (Optional)
Configure a unique ID of the rack on which the EM card is installed (up to 16 characters).
Specify any unique ID to identify the rack. Do not configure the same ID as another rack.
Only alphanumeric characters can be specified for the ID (the first character must be a
letter)
SET RACK UID <rack ID>
4. Execute the command below on the CLI to check that the settings you made have taken effect.
For details, refer to "Commands."
When the name of the rack has been configured, execute the SHOW RACK NAME
command.
When the ID of the rack has been configured, execute the SHOW RACK UID command.
Blade enclosure settings (EM card)
1. Confirm that the EM card is powered on.
2. Confirm that you have logged in as Administrator or a user whose access right is
ADMINISTRATOR or OPERATOR from a CLI of the EM serial console or EM console. If
you have not, log in as "Administrator" or a user whose access right is ADMINISTRATOR or
OPERATOR.
3. Configure the following information about the blade enclosure by running commands on the
CLI. For details, refer to "Commands."