DianaScope settings (EM card)
When using DianaScope Manager, you should create a user password of DianaScope Gateway on
an EM card. Follow the steps below to create a user account. DianaScope Manager requires an
authentication key when you register a server. Configure the user password as the authentication
key. Configure the static IP address of an EM card as the IP address of a server to be registered. For
the static IP address of an EM card, refer to "Network settings (EM card)." For information on
operation of DianaScope, refer to the installation guide of DianaScope, or the User's Guide of the
CPU blade.
1. Confirm that the EM card is powered on.
2. Confirm that you have logged in to the EM card as Administrator or a user whose access right
is ADMINISTRATOR or OPERATOR from the CLI of the EM serial console or EM console.
If you have not, log in to the EM by "Administrator" or a user whose access right is
ADMINISTRATOR or OPERATOR.
3. Run the following command on a CLI to configure the rack settings. For details, refer to
"Commands."
― Configuring a user's password of DianaScope (required for using DianaScope)
The following command configures the user's password of DianaScope Gateway of the
blade enclosure on which this EM card is installed. This user's password is also used as
the authentication key of DianaScope Manager.
The password can contain up to 16 alphanumeric characters.(the default value of the
password is "guest").
SET DSGPASSWORD <the password>
4. Run the following command on the CLI to confirm the configuration.(For details, refer to
"Commands."
Run the SHOW DSGPASSWORD command.
Hint
"SHOW DSGSTATE" command shows whether DianaScope Gateway is enabled or
not.(the default is enabled). When it is disabled, enable DianaScope Gateway by
using the "SET DSGSTATE" command. For information on each command, refer to
"Commands."
Other settings (CPU blade)
Refer to the User's Guide of the CPU blade.
Console connection to switch module/pass-through card
Follow the steps below to connect a console to a switch module/pass-through card via an EM card.
The procedure after connection depends on the specification of the console of the connected switch
module. The specification of the serial console is the same as when the console is directly
connected to the switch module/pass-through card. Configure settings by referring to the Uer's
Guide of the switch module after connection is achieved.
Some switch modules/pass-through cards cannot be connected. For details, refer to the User's
Guide of each switch module/pass-through card.
1. Confirm that the EM card is powered on.