User guide

138
Commands
Commands
The following table shows CLI commands supported by the SIGMABLADE-H EM firmware.
Indications in the "Access rights" column
A: operation by Administrator is possible.
O: operation by Operator is possible.
U: operation by User is possible.
Indications in the "EM card active/standby" column
A: settings can be configured from the active EM
S: settings can be configured from the standby EM
Indications in the "Backup target" column
Y: configuration information that is backed up
N: configuration information that is not backed up
About "Remarks" column
A description that has asterisk "*" at the end of it means that it is a required when you restore the
configuration
* EXPRESSSCOPE engine is referred to as BMC (Baseboard Management Controller) in this document.
* The CPU blade management commands and switch module management commands may not be
supported by some modules. (For further information, refer to the user's guide of each module.)
CLI commands of the SIGMABLADE-H EM firmware
Command
Access
rights
Description
Default value
EM card
active/
standby
Back
up
target
Remarks
General command
CLEAR SCREEN
A/O/U
Clears the terminal
screen.
N/A
A/S
N
EXIT
A/O/U
Terminates the CLI.
N/A
A/S
N
HELP
A/O/U
Displays help messages.
N/A
A/S
N
HISTORY
A/O/U
Displays the history of the
commands entered in the
CLI.
N/A
A/S
N
LOGOUT
A/O/U
Terminates the CLI.
N/A
A/S
N
QUIT
A/O/U
Terminates the CLI.
N/A
A/S
N
Rack management command.
SET RACK NAME
A/O
Configures the name of
the rack on which EM
card is installed. The rack
name must be Up to 32
characters.
""
(not configured)
A
Y
SHOW RACK
NAME
A/O/U
Displays the name of the
rack that is configured.
N/A
A/S
N
SET RACK UID
A/O
Configures a unique rack
ID. The rack unique ID
must be up to 16
characters.
""
(not configured)
A
Y
SHOW RACK UID
A/O/U
Displays the rack unique
ID that has been
configured.
N/A
A/S
N