User guide
163
Initializing the configuration data (restoring default values)
Overview
Restores default values and settings for the configuration retained by the EM firmware.
Command name
SET FACTORY
Argument
None
Example of execution
1Z34AB7890(Administrator)> set factory
Entering anything other than 'YES' will result in the command not executing.
All existing settings will be lost when this operation is run
and the Enclosure Manager will restart.
Are you sure you want to restore factory defaults? yes
Attempting to restore factory defaults. This operation may take some time.
Restoring factory default settings.
Enclosure Manager will now restart.
Example of execution of the command to initialize the configuration information
Default values
The following is a list of initial (default) values.
Default values of configuration information
Item
Default value
Remarks
Blade enclosure name
ブレ Serial number of the blade
enclosure
Rack name
""
EM card name
""
The name of the
EM card
Time zone
"JST"
EM language type settings
"JAPANESE"
Referred in
language switch of
SNMP trap
messages
Enable/disable network settings
SSH
Enable
Telnet
Enable
SNMP
Enable
NTP
Disable
TRUSTED HOST
Disable
Web
Enable
EM card IP address
"192.168.1.8"
CPU blade IP address
"192.168.1.12"
This address is
assigned in
sequence starting
from the one
assigned to Slot
#1.
Switch module IP address
"192.168.1.28"
Same as above
Netmask
"255.255.255.0"