User guide

198
Example of execution
1 Z34AB7890(Administrator)> show power
Redundancy Configuration: Power Supply Redundant
Power Policy Configuration: REDUNDANCY
Dynamic Power Savings : Off
Limit DC Output : 4500 W
Capacity: 6750 W
Redundant Capacity: 2250 W
Redundant Power: 4500 W
Power Allocated: 1060 W
Consumed Power: 559 VA
Maximum Consumable Power: 5472 VA
1Z34AB7890(Administrator)>
Example of execution of the command to display power-related configuration information
Default value
Power redundancy mode: Individual power redundancy mode (N+1 redundant mode)
Power control policy: Performance preferred mode
Power saving mode: OFF (disable)
Maximum consumable power: OFF (disable)
Supplementary information
Displaying the EM card /EM firmware version
Overview
Displays the version of EM card/EM firmware.
Command name
SHOW VERSION
Argument
None
Example of execution
1Z34AB7890(Administrator)> show version
Enclosure Manager Hardware Version: 1.00
Enclosure Manager Firmware Version: 00.30 alpha2 (2006.07.03 22:07:33)
1Z34AB7890(Administrator)>
Example of execution of the command to display the EM card/EM firmware version
Default value
Supplementary information
Updating EM firmware
Overview
Updates the EM firmware
Downloads the EM firmware image from a specified URLhttp, ftp, or tftp and updates the EM firmware
automatically. The EM firmware automatically reboots after the update in order to apply the updated