User guide

209
Command name
SET SERVER POWERONDELAY
First Argument
<Slot number> | <Slot number> - <Slot number> | <Slot number> , <Slot number> | "ALL"
Second Argument
<Delay time>
Configure in seconds
Range of configurable values: 0 to 86400 ("0": disable)
Example of execution
1Z34AB7890(Administrator)> set server powerondelay 1 864
Blade 1's PowerOnDelayTime changed to 864
1Z34AB7890(Administrator)>
Example of execution of the command to configure the power-on delay time of the CPU blade
Default value
0 disable
Supplementary information
Displaying the power-on delay time of the CPU blade
Overview
Displays the power-on delay time of the specified CPU blade.
Command name
SHOW SERVER POWERONDELAY
Argument
None
Example of execution
1Z34AB7890(Administrator)> show server powerondelay
Enclosure Manager Uptime = 1173 (sec)
Slot Blade Name Delay (sec)
---- -------------------------------- -----------
1 R2-EE-03 864
2 [Subsumed] 0
3 [Absent] 0
4 [Absent] 0
5 [Absent] 0
6 [Absent] 0
7 [Absent] 0
8 [Absent] 0
9 Virtual I/O Blade 0
10 [Absent] 0
11 [Express5800/120Bb-6] 0
12 [Absent] 0
13 [Absent] 0
14 [Absent] 0
15 [Absent] 0
16 [Express5800/120Bb-d6] 0
1Z34AB7890(Administrator)>
Example of execution of the command to display the power-on delay time of the CPU blade