User guide

215
Example of execution
1Z34AB7890(Administrator)> restart switch 4
Entering anything other than 'YES' will result in the command not executing.
Are you sure you want to restart the Switch Module? YES
Resetting Switch Module in slot 4.
1Z34AB7890(Administrator)>
Example of execution of the command to restart switch modules
Default value
Supplementary information
Type YES when the instruction is shown on the screen.
Configuring a User Assigned Name of a switch module
Overview
Assigns a name to the specified switch module
Command name
SET SWITCH NAME
First argument
<Slot number>
Second argument
<User Assigned NAME>
Use up to 32 alphanumeric characters or some symbols (Blank, Hyphen, or Underscore).
Example of execution
1Z34AB7890(Administrator)> set switch name 1 Switch1
Changed the user assigned name for Switch Module #1 to "Switch1".
1Z34AB7890(Administrator)>
Example of execution of the command to configure a user assigned name of the switch module
Default value
Supplementary information
Controlling the ID LED of a switch module
Overview
Turn on / off the ID LED of the specified switch module
Command name
SET SWITCH UID
First argument
<Slot number>
Second argument
"ON" | "OFF"