User guide

221
EM management commands
Configuring the unique name of an EM card
Overview
Configures a name unique to an EM card.
Command name
SET EM <Slot number> NAME <EM card name>
First argument
<Slot number> (optional)
The blade enclosure supports up to two EM cards. Specify the slot number of the target EM card.
You can specify either 1 or 2.
When you skip the slot number, the EM card you are now logging on is specified.
Second argument
<EM card name>
Use up to 32 alpha numeric characters and some symbols (blank, hyphen, or underscore).
Note:
No reserved words can be specified for <EM card name>
Reserved word means terms defined in command line such as "SET", "ADD", and "RACK".
Example of execution
1Z34AB7890(Administrator)> set em name EM1
Enclosure Manager name changed to EM1.
1Z34AB7890(Administrator)>
Example of modifying an EM card name
Default value
"" (not configured)
Supplementary information
Controlling the EM card LED
Overview
Turn on / off the ID LED of an EM card.
Command name
SET EM UID
First argument
<Slot number > (optional)
The blade enclosure supports up to two EM cards. Specify the slot number of the target EM card.
You can specify either 1 or 2.
When you skip the slot number, the EM card you are now logging on is specified.
Second argument
"ON" | "OFF"