User guide

223
Information to be displayed
EM card name
Active/standby
ID LED status
EM card status
EM language type
Command name
SHOW EM STATUS
Argument
<Slot number> | "ALL" (optional)
The blade enclosure can supports to two EM cards. Specify the slot number of the target EM card.
You can specify either 1 or 2.
When you skip the slot number, the EM card you are now logging on is specified.
Example of execution
1Z34AB7890(Administrator)> show em status all
NEC Enclosure Manager #2 Status:
Name : EM-0016355E5C2E
Role : Standby
UID : Off
Status : OK
Language : JAPANESE
NEC Enclosure Manager #1 Status:
Name : EM-0016355E5C10-1
Role : Active
UID : Off
Status : OK
Language : JAPANESE
Redundancy status : NORMAL
1Z34AB7890(Administrator)>
Example of status of EM cards
Default value
Supplementary information
About Redundancy status
NORMAL EM cards are successfully in the redundant mode.
NOT LINK UP Link with the other EM card is not achieved.
DEGRADED Communication to the other card is disconnected, synchronizing the
configuration between two EM cards has failed, or the EM cards use
different versions of the EM firmware.
FAILED There is a fatal error in communication to the other EM card, or the other
EM card has failed to update the EM firmware.
UNKNOWN The status of the other EM card cannot be retrieved.
NOT REDUNDANT EM cards are not in the redundant mode.
Configuring the language type for EM cards