Rear panel
Connect the RJ-45 network cable, Fiber Channel cable, power cord, PS/s device, serial cable and/or display
unit to the proper connectors on rear panel.
AC inlet
The last cable to be connected is the power cable included with the power unit.
Connect the power cable to the power unit and plug it into an appropriate AC outlet.
CHECK:
When you connect a AC Cable to the power unit, install the AC Cable connector to the AC inl
et and fix the AC Cable with the tie lap (black band).
IMPORTANT:
Do not connect any of the power cables to an AC voltage outlet other than the one of the specified
voltage.
*Input : 100VAC/200VAC(mutually exclusive)
Some third-party devices are not compatible with the Blade Enclosure. Consult third-party agents
about the NEC-product compatibility before purchasing a non-NEC, third-party peripheral device or
interface cable.
Use cable ties to bind and secure power cables and interface cables in order to prevent them from
getting tangled.
Arrange cable alignments to avoid them from touching rack doors and side guide rails or blocking
the internal air flow.
When using an uninterruptible power supply (UPS), connect the power cable from the Blade Enclosure to a
service outlet at the rear of the power supply. For more information on UPS location, refer to the
UPS-included instructions.
If the power cable from the Blade Enclosure is connected to a UPS, change the relevant BIOS settings on
each blade to match the UPS. Do so by changing the values of the parameters displayed on the
AC-LINK. under System Hardware BIOS menu.