User's Guide

112
Configuring IP addresses
Overview
Configures IP addresses of EM cards, CPU blades, and switch modules
The address of CPU blade and switch module means the Slot 1 address. From the Slot 2 on,
subsequent addresses are configured.
Command name
SET NETWORK ADDRESSRANGE
First Argument
<EM card IP address>
Second Argument
<CPU blade/switch modulate start up IP address>
Third Argument
<Subnet mask>
Execution example
Example of execution of the command to set the IP address
Default value
Start up IP address
EM card : 192.168.1.8
CPU blade/switch module : 192. 168.1.12
Subnet mask
255.255.255.0
Supplementary information
The following values cant be specified for <CPU blade/switch module start up IP address>.
*.*.*.0, *.*.*.255 (*.: the wildcard character)
For detail son how to set, refer to Network settings (EM card)