User's Guide

126
Restarting the EM firmware
Overview
Restarts the EM firmware.
Command name
RESTART EM
Argument
None
Execution example
Default value
Supplementary information
Only users with the ADMINISTRATOR right can use this command.
Type YES as prompted by a message on the screen.
While an EM card is restarting, DO NOT install, remove, power on or power off any module. It may
cause not only the restarting the failure but also malfunction of the module. By the same token, DO
NOT perform ID LED on or off for the installed modules. ID LEDs may not be lit or lit off properly.
Configuring the function to automatically terminate CLI
Overview
Specify time to terminate a CLI that has been left without being operated.
Command name
SET AUTOLOGOUT
Argument
<Logout time>
Specify by a decimal number between the range of 0 to 60 (minutes).
If zero (0) is specified, the function to automatically terminate CLI will be disabled.
Execution example
Default value
60
Supplementary information
This command takes effect only during the current CLI session.