User's Guide
168
Displaying the status of switch modules
Overview
Displays the operational statuses of the switch module
Information to be displayed:
Operation status
Thermal status
CPU status on switch modules
STATUS LED status
ID LED status
Power-supply status
E-FUSE status
Command name
SHOW SWITCH STATUS
Argument
<Slot number> | <Slot number> - <Slot number> | <Slot number> , <Slot number> | “ALL”
<Slot number> and „-‟(hyphen) or „,‟(comma) must be separated by a blank space.
Execution example
Example of execution of the command to display status of switch modules
Default value
Supplementary information
About Diagnostic Status
Internal Data Shows FRU information validity. OK: valid, Failed: invalid
(checksum error, etc.)
Management Processor Shows the status of management processor on the switch module.
OK: normal, Failed: failure
Thermal Warning Shows the temperature warning status. OK: normal temperature,
Failed: warning temperature, Not Performed: not checked
Thermal Danger Shows abnormal temperature status. OK: normal temperature,
Failed: abnormal temperature, Not Performed: not checked
I/O Configuration Shows E-Keying status. OK: E-Keying succeeded, Failed:
E-Keying failed
Power Shows the power status. OK: Normal power status, Failed: power
problem, Not Performed: not checked
Device Failure Shows failure status. OK: Normal operation, Failed: failure, Not
Performed: not checked
Device Degraded Shows degraded status. OK: normal operation, Failed: degraded,
Not Performed: not checked