User's Guide

219
TIPS:
The following is the default configuration of the IP addresses.
Active EM Floating IP: 192.168.1.8/24
Standby EM Floating IP: 192.168.1.9/24
EMs Static IP in Slot #1: 192.168.1.10/24
EMs Static IP in Slot #2: 192.168.1.11/24
CHECK:
Is the last digit of the EM card IP address is a multiple of four?
If it is not set as such, registering EM card to the DianaScope Manager is unavailable.
4. DHCP support:
This specifies whether or not to use the IP address support function to the CPU blade and the
switch module. Default is enable.
TIPS:
Even if ;you specify DHCP support as disable, DHCP base address and NTP server IP address,
both described later, remain on the configuration. This affects nothing on the performance if you
decided not to use the DHCP function, as those values will not be referred.
5. EM Card DHCP base IP address:
This specifies the base address for EM cards DHCP function in order to assign the CPU blades
and the switch modules IP address. (Subnet mask value is use the one specified for EM Card
netmask)
6. EM Card DHCP NTP server IP address:
Specify this when you wish to distribute the outside NTP servers IP address with DHCP function
of the EM card along with distributing the IP addresses for the CPU blade and the switch module.