User's Guide
34
Chapter 3
Using Command Line Console Feature
This section explains the command line console feature.
Connection
To use the command line console feature, a management console (e.g., personal computer) must be connected to
the management port.
Connecting with Management Port
The EM card has two interfaces; the serial port and the network port (100Base-Tx/10Base-T) as a management
port.
IMPORTANT: To connect with the management network, use "Management LAN
Interface" at the front of the EM card.
NOTE: Connect with the management port when providing initial setup or
maintenance of EM card.
Connection via Serial Port
Connect a management console (e.g., personal computer) to the serial port. When you use the EM card for the
first time, the management console must be connected.
The management console such as PC must have a communication software conformed to VT-100.
Set the communication software as follows:
– Baud rate: 115200bps
– Data length: 8 bits
– Parity: None
– Stop bit: 1
– Flow control: None
IMPORTANT: A leased line cannot be connected to the serial port directly.