User's Guide

44
Configure community names. (The default community name value for read, write
and trap operations is "public".)
SET SNMP COMMUNITY READ <the community name that allows a
read operation>
SET SNMP COMMUNITY WRITE <the community name that allows a
write operation>
SET SNMP COMMUNITY TRAP <the community name that allows a
trap operation>
― Configuring contact name (Optional)
Configure a SNMP contact name.
(Configure the contact address on SNMP as you like. (e.g. the address of the server
room where the rack with this products installed is located.)
SET SNMP CONTACT <the contact name>
Location information setting (Required to display location information correctly
on NEC ESMPRO Manager.)
Configure the location information of the blade enclosure.
Specify <the location in the rack of the blade enclosure> and
<the height of the rack> by unit (number).
SET SNMP LOCATION <the LOCATION name>
SET SNMP LOCATION ENCLOSURE <the location within rack of the
blade enclosure>
SET SNMP LOCATION RACKHEIGHT <the height of the rack>
― Specifying SNMP trap destination
(When you use the SNMP function, it is required to set one or more IP address for
trap destination.)
Specify SNMP trap destination.
You can specify up to three addresses.
ADD SNMP TRAPRECEIVER <the IP address to be notified trap>
Enabling the TrapACK function (Optional)
Enable the TrapACK function (the function to wait Ack for SNMP trap).
ENABLE SNMP TRAPACK
TIPS:
Execute the SHOW NETWORK command to confirm if the SNMP function is enabled. (SNMP
function is enabled by default.) If disabled, execute the ENABLE SNMP command to enable the
SNMP function. (For information on the commands, Hint refer to Commands.)
You can set SNMSP trap destination supported SNMP TrapAck functions (e.g. NEC ESMPRO
Manager and Agent) for SNMP TRAPRECEIVER. If you set wrong SNMSP trap destination and
enable the SNMP TrapAck functions of the EM firmware, the same trap is issued two or more times.
4. Execute the command below on the CLI to check the settings you made have taken effect.
(For details, refer to Commands.)
After making changes, execute the SHOW SNMP command.
For performing the SNMP test, execute the TRAPTEST command. (When you are using NEC
ESMPRO Manager, the message, AlertManager tested: Notification test is performed.
(TEST-AlertManager) is displayed.)