User Guide
57
Important
● When this card is connected to a CPU blade by using a mezzanine expansion slot, you need as
many mezzanine cards as the number of mezzanine expansion slots to be used. (For more
information, see the User‟s Guide of the Blade Enclosure.)
● If a single mezzanine card (FibreChannel controller) uses two ports, you need two sets of this
card.
● To connect an FC cable, you need the SFP module shipped with this product or specified by
NEC. The SFP module that can be installed depends on the type of the switch
module/pass-through card.
● This product is for 4Gbps or 2Gbps. Do not connect a 1Gbps product.
Connection of FC connectors: between FC Pass-Through Cards and FibreChannels
Up to 16 units
FC ports (16 ports)
・・・
CPU blade
Blade enclosure (SIGMABLADE-H)
FC ports (16 ports)
2/4Gbps
FC Pass-Through Card 1
FC Pass-Through Card 2
The communication ports 1 to 16 of this card correspond to mezzanine cards for the CPU
blades installed in the blade slots 1 to 16 of the Blade Enclosure. For information on this
card‟s communication ports and blade slots, see “Components” and the User‟s Guide of the
Blade Enclosure, respectively.
FC Controller
FC Controller
FC Controller
Port1
Port2
Port1
Port2
Port1
Port2
FC Controller
Port1
Port2