User Guide
64
Follow the instructions below to power off a switch module or pass-through card by using the CLI:
1. Check that the EM card is powered on.
2. Connect to the CLI of the EM card and log in as “Administrator” or with the access rights of an
ADMINISTRATOR or OPERATOR.
3. Enter the following command. For details, see “Command specifications.”
Powering off
Powers off a specified switch module or pass-through card:
POWEROFF SWITCH <slot number>
Follow the instructions below to restart a switch module or pass-through card by using the CLI:
1. Check that the EM card is powered on.
2. Connect to the CLI of the EM card and log in as “Administrator” or with the access rights of an
ADMINISTRATOR or OPERATOR.
3. Enter the following command. For details, see “Command specifications.”
Restarting a switch module or pass-through card:
Restarts a specified switch module or pass-through card:
RESTART SWITCH <slot number>