User Guide
75 
Default value 
Supplementary information 
Displaying information on switch modules 
Overview 
Displays information on specified switch modules 
Information to be displayed 
Switch module type 
Manufacturer‟s name 
Product name 
Product part number 
Product version 
Product serial number 
IP address 
Firmware version, etc. 
Command name 
SHOW SWITCH INFO 
Argument 
<slot number> | <slot number> - <slot number> | <slot number> , <slot number> | "ALL" 
<slot number> and „-„(hyphen) or „,‟(comma) must be separated by a blank space. 
Example of execution 
1Z34AB7890(Administrator)> show switch info 5 
5. <Single> NEC 4Gb Fibre Channel Pass-thru Module for SIGMABLADE-H 
        URL:[N/A] 
        P/N:406740-B21   S/N:1A567B9EF2   SerPortRoute:N/A EthPortRoute:N/A 
        Name:Switch5                      IP:N/A 
        PrtDis:PowerOn   TmpSen:Present   JS2Conn:Absent   EthExtIf:Absent 
        EthEMIf:Absent   Baud:9600bps     SerExtIf:Present SerEMIf:Absent 
        ISMIC FW Ver:01.02      Internal FW Ver:Not Available 
1Z34AB7890(Administrator)>  
Example of execution of the command to display switch module information 
Default value 
Supplementary information 
About SerPortRoute and EthPortRoute 
SerPortRoute: the direction of the internal serial interface 
EthPortRoute: the direction of the internal Ethernet interface 
EM    This interface connects to the EM card internal interface 
Ext    This interface connects to the switch module external interface 
N/A    This interface is not supported. 
Controlling the ID LED of a switch module 