Reference Guide
N8406-022A 1Gb Intelligent L2 Switch Browser-based Interface Reference Guide 109 
RMON Alarm Configuration 
To display the following form, go to the RMON Alarm Groups Configuration form. Select an Alarm Group, or 
open the Alarm folder and click Add Alarm Group. 
The following table describes the Alarm Group Configuration controls: 
Table 90 Alarm Group Configuration controls 
Control 
Description 
Alarm Group ID 
Configures the numeric identifier of the Alarm index. 
MIB Object ID 
Configures an alarm MIB Object Identifier. 
The alarm OID can have a maximum of 127 characters. 
Rising Limit 
Configures the rising threshold for the sampled statistic. When the current sampled value is 
greater than or equal to this threshold, and the value at the last sampling interval was less than 
this threshold, a single event is generated. 
Falling Limit 
Configures the falling threshold for the sampled statistic. When the current sampled value is 
less than or equal to this threshold, and the value at the last sampling interval was greater than 
this threshold, a single event is generated. 
Rising Event Index 
Configures the rising alarm event index that is triggered when a rising threshold is crossed. 
The range is from 0 to 65535. The default value is 0. 
Falling Event Index 
Configures the falling alarm event index that is triggered when a falling threshold is crossed. 
The range is from 0 to 65535. The default value is 0. 
Alarm Type 
Configures the alarm type as rising, falling, or either (rising or falling). 
Sample Type 
Configures the method of sampling the selected variable and calculating the value to be 
compared against the thresholds, as follows: 
  abs: absolute value, the value of the selected variable is compared directly with the 
thresholds at the end of the sampling interval. 
  delta: delta value, the value of the selected variable at the last sample is subtracted from 
the current value, and the difference compared with the thresholds. 
Polling Interval 
Configures the time interval over which data is sampled and compared with the rising and 
falling thresholds. 
The range is from 1 to 3600 seconds. The default is 1800 seconds. 
Owner 
Enter a text string that identifies the person or entity that uses this alarm index.  
The owner can have a maximum of 127 characters. 