Reference Guide
N8406-022A 1Gb Intelligent L2 Switch Browser-based Interface Reference Guide 122 
Uplink Failure Detection Configuration 
To display the following form, select Uplink Failure Detection (click the underlined text, not the folder). 
Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use this menu to 
configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. 
When UFD is enabled and a Failover Pair is configured, the switch automatically disables ports in the LtD if it 
detects a failure in the LtM. The failure conditions which are monitored in the LtM group include port link 
state moving to down, or port state moving to Blocking if Spanning Tree Protocol is enabled.  
The following table describes the Uplink Failure Detection (UFD) configuration controls: 
Table 103 Uplink Failure Detection Configuration controls 
Control 
Description 
UFD state 
Globally turns UFD on or off.  
FDP 
Displays the Failure Detection Pair Configuration form. 










