Clearing dump information
Command: /maint/cldmp
To clear dump information from flash memory, at the Maintenance# prompt, enter:
Maintenance# cldmp
The switch clears the dump region of flash memory and displays the following message:
FLASH dump region cleared.
If the flash dump region is already clear, the switch displays the following message:
FLASH dump region is already clear.
Panic command
Command: /maint/panic
The panic command causes the switch to immediately dump state information to flash memory and automatically
reboot.
To select panic, at the Maintenance# prompt, enter:
>> Maintenance# panic
A FLASH dump already exists.
Confirm replacing existing dump and reboot [y/n]:
Enter y to confirm the command:
Confirm dump and reboot [y/n]: y
A list of messages is displayed:
Starting system dump...done.
Reboot at 11:54:08 Wednesday October 30, 2005...
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rebooted because of console PANIC command.
Booting complete
Unscheduled system dumps
If there is an unscheduled system dump to flash memory, the following message is displayed when you log on to
the switch:
Note: A system dump exists in FLASH. The dump was saved
at 13:43:22 Wednesday October 30, 2005. Use /maint/uudmp to
extract the dump for analysis and /maint/cldmp to
clear the FLASH region. The region must be cleared
before another dump can be saved.