Reference Guide

N8406-022A 1Gb Intelligent L2 Switch Browser-based Interface Reference Guide 74
The following table describes the Switch Management Processor Configuration (SNMP) controls:
Table 59 Switch Management Processor Configuration (SNMP) controls
Control
Description
SNMP System Name
Configures the name for the system. The name can have a maximum of
64 characters.
SNMP Location
Configures the name of the system location. The location can have a
maximum of 64 characters.
SNMP Contact
Configures the name of the system contact. The contact can have a
maximum of 64 characters.
SNMP Read Community String
Configures the SNMP read community string. The read community
string controls SNMP “get” access to the switch. It can have a maximum
of 32 characters. The default read community string is public.
SNMP Write Community String
Configures the SNMP write community string. The write community
string controls SNMP “set” and “get” access to the switch. It can have a
maximum of 32 characters. The default write community string is
private.
SNMP state machine timeout (1-30 minutes)
Sets the timeout value for the SNMP state machine. The default is 5
minutes.
Send SNMP Auth. Failure Traps?
Enables or disables the use of the system authentication trap facility.
The default setting is disabled.
Switch Management Processor Configuration buttons
The following table describes the Switch Management Processor Configuration buttons:
Table 60 Switch Management Processor Configuration buttons
Control
Description
Submit
Sends this form to the switch. Any configuration changes are placed in the “pending” state
and do not take effect until the toolbar Apply command is given.
Diff
Shows any pending configuration changes.
Diff Flash
Compares new configuration with the flash configuration.
Revert
Removes pending configuration changes between apply commands. Use this command to
restore configuration parameters set since last apply command.
Revert Apply
Removes pending configuration changes between save commands. Use this command to
restore configuration parameters set since last save command.