Command Reference Guide
N8406-023 1Gb Intelligent L3 Switch Command Reference Guide (AOS) 149
Table 177 Port Mirroring Configuration Menu options
Command
Description
add <mirrored port> in|out|both
Adds the port to be mirrored. This command also allows you to enter
the direction of the traffic. It is necessary to specify the direction
because:
If the source port of the frame matches the mirrored port and the
mirrored direction is ingress or both (ingress and egress), the
frame is sent to the mirrored port.
If the destination port of the frame matches the mirrored port
and the mirrored direction is egress or both, the frame is sent to
the monitoring port.
rem <mirrored port>
Removes the mirrored port.
delete
Deletes this monitored port.
cur
Displays the current settings of the monitoring port.
Uplink Failure Detection configuration
Command: /cfg/ufd
[Uplink Failure Detection Menu]
fdp - Failure Detection Pair Menu
on - Globally turn Uplink Failure Detection ON
off - Globally turn Uplink Failure Detection OFF
cur - Display current Uplink Failure Detection configuration
Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use this menu to
configure Failure Detection Pairs of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. When
each UFD is enabled and a Failure Detection Pair is configured, the switch automatically disables ports in the LtD if
it detects a failure in the LtM. The failure conditions which are monitored in the LtM group include port link
state moving to down, or port state moving to Blocking if Spanning Tree Protocol is enabled.
The following table describes the Uplink Failure Detection (UFD) Configuration Menu options.
Table 178 Uplink Failure Detection Configuration Menu options
Command
Description
fdp <FDP number>
Displays the Failure Detection Pair menu.
on
Globally turns Uplink Failure Detection ON.
off
Globally turns Uplink Failure Detection OFF. This is the default.
cur
Displays the current Uplink Failure Detection configuration parameters.
Failure Detection Pair configuration
Command: /cfg/ufd/fdp <FDP number>
[FDP 1 Menu]
ltm - Link to Monitor Menu
ltd - Link to Disable Menu
ena - Enable FDP
dis - Disable FDP
current - Display current FDP configuration
Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM) and one
Link to Disable (LtD). When the switch detects a failure on the LtM, it automatically disables the ports in the LtD.
The following table describes the Failure Detection Pair (FDP) configuration Menu options.
Table 179 Failure Detection Pair Configuration Menu options
Command
Description
ltm
Displays the Links to Monitor menu.
ltd
Displays the Links to Disable menu.
ena
Enables the FDP Parameters.
dis
Disables the FDP Parameters. This is the default.
current
Displays the current FDP configuration.