Handbook
N8406-023 1Gb Intelligent L3 Switch Application Guide 139
Configure RMON Alarms (BBI example 2)
1. Configure an RMON Alarm group.
a. Click the Configure context button.
b. Open the Switch folder, and select RMON > Alarm > Add Alarm Group.
c. Configure RMON Alarm Group parameters to check icmpInEchos, with a polling interval of 60, a rising
limit of 200, and a rising event index of 5. This configuration creates an RMON alarm that checks
icmpInEchos on the switch once every minute. If the statistic exceeds 200 within a 60 second interval,
an alarm is generated that triggers event index 5.
d. Click Submit.
Open
Select










