The following table describes the RMON Alarm Menu options.
Table 176 RMON Alarm Menu options
Command
Description
oid <1-127 characters>
Configures an alarm MIB Object Identifier.
The alarm OID can have a maximum of 127 characters.
intrval <1-65535>
Configures the time interval over which data is sampled and
compared with the rising and falling thresholds.
The range is from 1 to 65535 seconds. The default is 1800 seconds.
sample abs|delta
Configures the method of sampling the selected variable and
calculating the value to be compared against the thresholds, as
follows:
abs: absolute value, the value of the selected variable is
compared directly with the thresholds at the end of the sampling
interval.
delta: delta value, the value of the selected variable at the last
sample is subtracted from the current value, and the difference
compared with the thresholds.
The default is abs.
almtype rising|falling|either
Configures the alarm type as rising, falling, or either (rising or
falling). The default is either.
rlimit < -2147483647 to
2147483647>
Configures the rising threshold for the sampled statistic. When the
current sampled value is greater than or equal to this threshold,
and the value at the last sampling interval was less than this
threshold, a single event is generated. The default value is 0.
flimit < -2147483647 to
2147483647>
Configures the falling threshold for the sampled statistic. When the
current sampled value is less than or equal to this threshold, and
the value at the last sampling interval was greater than this
threshold, a single event is generated. The default value is 0.
revtidx <0-65535>
Configures the rising alarm event index that is triggered when a
rising threshold is crossed.
The range is from 0 to 65535. The default value is 0.
fevtidx <0-65535>
Configures the falling alarm event index that is triggered when a
falling threshold is crossed.
The range is from 0 to 65535. The default value is 0.
owner <1-127 characters>
Enter a text string that identifies the person or entity that uses this
alarm index.
The owner can have a maximum of 127 characters.
delete
Deletes this alarm index.