Command Reference Guide
Error! Use the Home tab to apply 見出し 1 to the text that you want to appear here. 52
Table 41 RMON History Information Menu /info/rmon/hist
Command
Usage
Gbnum
Displays the number of granted buckets that may hold sampled data.
RMON alarm information
Command: /info/rmon/alarm
RMON Alarm group configuration:
Index Interval Type rLimit fLimit rEvtIdx fEvtIdx last value
----- -------- ---- -------- -------- ------- ------- ----------
1 30 abs 10 0 1 0 0
2 900 abs 0 10 0 2 0
3 300 abs 10 20 0 0 0
4 1800 abs 10 0 1 0 0
5 1800 abs 10 0 1 0 0
8 1800 abs 10 0 1 0 56344540
10 1800 abs 10 0 1 0 0
11 1800 abs 10 0 1 0 0
15 1800 abs 10 0 1 0 0
18 1800 abs 10 0 1 0 0
100 1800 abs 10 0 1 0 0
Index OID
----- ------------------------------
1 1.3.6.1.2.1.2.2.1.10.257
2 1.3.6.1.2.1.2.2.1.11.258
3 1.3.6.1.2.1.2.2.1.12.259
4 1.3.6.1.2.1.2.2.1.13.260
5 1.3.6.1.2.1.2.2.1.14.261
8 1.3.6.1.2.1.2.2.1.10.280
10 1.3.6.1.2.1.2.2.1.15.262
11 1.3.6.1.2.1.2.2.1.16.263
15 1.3.6.1.2.1.2.2.1.19.266
18 1.3.6.1.2.1.2.2.1.10.279
100 1.3.6.1.2.1.2.2.1.17.264
The following table describes the RMON Alarm Information parameters.
Table 42 RMON Alarm Information Menu /info/rmon/alarm
Command
Usage
Index
Displays the index number that identifies each alarm instance.
Interval
Displays the time interval over which data is sampled and compared with the rising and
falling thresholds.
Type
Displays the method of sampling the selected variable and calculating the value to be
compared against the thresholds, as follows:
abs: absolute value, the value of the selected variable is compared directly with the
thresholds at the end of the sampling interval.
delta: delta value, the value of the selected variable at the last sample is subtracted
from the current value, and the difference compared with the thresholds.
rLimit
Displays the rising threshold for the sampled statistic.
fLimit
Displays the falling threshold for the sampled statistic.
rEvtIdx
Displays the rising alarm event index that is triggered when a rising threshold is crossed.
fEvtIdx
Displays the falling alarm event index that is triggered when a falling threshold is
crossed.
Last value
Displays the last sampled value.
OID
Displays the MIB Object Identifier for each alarm index.