User's Manual

CHAPTER 4 NDA-24298
Page 80
Issue 1
ASYD : Assignment of System Data
1
45
Abnormal Call, Short Duration Timer for Automatic Circuit
Assurance service (when INDEX = 44, b
0
= 1)
Timer counter (TC) is to be assigned a value from 02 Hex to FF
Hex. (2 - 255 sec.)
Timer Value = TC × 1 sec.
Note: When TC = 00 Hex, this timer is not set.
46
Abnormal Call, Long Duration Timer for Automatic Circuit
Assurance service
(when INDEX = 44, b
0
= 1)
TC is to be assigned a value from 01 Hex to FF Hex. (1 - 255
min.)
Timer Value = TC × 1 min.
Note: When TC = 00 Hex, this timer is not set.
47
b
0
Traffic Measurement Indication
0/1 = CCS Indication/Erlang Indication
b
2
TCFI Timer (Timer Internal Between Messages)
b
2
b
1
b
2
b
1
0 0 = 2 seconds 1 1 = Application Dependent
(Standard Assignment)
0 1 = 4 seconds
1 0 = 8 seconds
Display for TCFD
0/1 = MSG/Last input
0 = Normal assignment
b
2
0b
3
0b
4
SCF (FN = 127) Tone Control
0/1 = Invalid/Valid
0b
5
Not used
0b
6
b
7
Traffic Measurement for Terminal and Route Traffic (ATRF)
0/1 = Out/In Service
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT