NDA-24298 CHAPTER 4
Page 151
Issue 1
ASYD : Assignment of System Data
1
294
b
0
Output Port for SMDR D Apparatus
When b
4
= 0 (IOC equipment No. 0)
b
0
= Port 0 b
1
= Port 1 b
2
= Port 2 b
3
= Port 3
When b
4
= 1 (IOC equipment No. 1)
b
0
= Port 4 b
1
= Port 5 b
2
= Port 6 b
3
= Port 7
1 is to be assigned to each bit corresponding to the Port No.
Note 1: Among the SMDR equipment that has the same IOC
equipment number, double assignment of port is
rejected.
Note 2: The ports to be designated by SYS-1, INDEX 288, 290,
292, and 294 are limited to those designated as SMDR
by AIOC.
Note 3: This data is assigned at the node to which SMDR with
IOC interface is connected. In case SMDR is not
connected to the node, this data setting is fixed to 0.
b
1
b
2
b
3
b
4
b
5
Expanded SMDR for D apparatus.
b
6
Not used
b
7
295
b
0
Fault detection timer of SMDR D
Value for the first digit (min):
(0~9) Hex
A~F Hex: Not used
Timer value ranges
from 1 to 99 min-
utes.
00 Hex: Without
fault detection
Normally, Assign 00
Hex.
b
1
b
2
b
3
b
4
Fault detection timer of SMDR D
Value for the second digit (min):
(0~9) Hex
A~F Hex: Not used
b
5
b
6
b
7
296 00 Not used
303 00 Not used
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 511
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
~
~
~