User's Manual

NDA-24298 CHAPTER 4
Page 173
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
ASYDL: Assignment of System Data into Local DM (LDM)
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512 - 1535
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
512
b
0
Fusion Point Code (FPC) of self node in hexadecimal.
FPC 1-253 (01 Hex-FD Hex)
Note: After assigning/changing the FPC, System
Initialization (Non-Load Initialization) is
required. Assign only for Fusion Network.
b
1
b
2
b
3
b
4
b
5
b
6
b
7
513 01
b
0
Local Data Memory (LDM) usage. Assign 1 (the
memory block is used) to the corresponding bit.
b
1
b
2
b
3
b
4
b
5
b
6
b
7
514 01
b
0
Network Data Memory (NDM) usage. Assign 1 (the
memory block is used) to the corresponding bit.
b
1
b
2
b
3
b
4
b
5
b
6
b
7
Note 1: Necessary data for the programming using commands for LDM. Usually 01H is assigned.
When the Local Data Memory is not enough, change the value from 03H to 07H.
Note 2: Necessary data for the programming commands for NDM. Usually 01H is assigned.
When the Network Data Memory is not enough, change the value from 03H
07H
0FH
1F.
bit Memory
b
0
Memory Block #0
b
1
Memory Block #1
b
2
Memory Block #2
bit Memory
b
0
Memory Block #0
b
1
Memory Block #1
b
2
Memory Block #2
b
3
Memory Block #3
b
4
Memory Block #4
b
5
Memory Block #5
b
6
Memory Block #6