User's Manual

NDA-24298 CHAPTER 4
Page 493
Issue 1
AIZP : Assignment of Internal Zone Paging Data
AIZP: Assignment of Internal Zone Paging Data
1. General
This command assigns Internal Zone Paging group data. If the designated group number has already been
assigned, the current data is displayed. If new data is to be assigned, the old data must be deleted before entering
new data.
2. Precautions
1. Each Internal Zone Paging group must be composed of D
term
station (TEC = 12).
2. A maximum of 24 stations can be assigned to one Internal Zone Paging group.
3. A maximum of 99 groups can be assigned to one tenant.
4. One D
term
station can be assigned to multiple Internal Zone Paging groups.
5. Regardless of the tenant data table development, any D
term
station in the system can be assigned to an
Internal Zone Paging group.
3. Data Entry Instructions
Enter TN number of Internal Zone Paging station.
IZPTN
Enter the station number.
IZPSTN
NUMBER OF
STATIONS (CNT)
TENANT NUMBER
(TN)
INTERNAL ZONE
PAGING GROUP
(IZPG) 1-99
INTERNAL ZONE
PAGING TENANT
NUMBER (IZP TN)
INTERNAL ZONE
PAGING STATION
NUMBER (IZP STN)
MAXIMUM 5 DIGITS
Enter the group number with a range from 1 to 99.
IZPG
1
2
3