User's Manual

NDA-24298 CHAPTER 4
Page 539
Issue 1
ARTDN : Assignment of Route Class Data for NDM
Figure 4-16 SMDR2 (ARTDN)
Table 4-22 SMDR2 (ARTDN)
CONTENTS/INPUT 0123456789101112131415
b0
0-Detailed billing is not required for incoming calls.
××××
1-Detailed billing is required for incoming calls.
××××
b1
0-Detailed billing is required for toll and local
outgoing calls.
×× ××
1-Detailed billing is required only for toll outgoing
calls.
×× ××
b2, 3
0-
1-Metering pulses are used.
××××
2-
3-
b
0
b
1
b
2
b
3
0/1: -/Incoming Call (SMDR is required)
0/1: SMDR is required for toll and local out-
going calls/SMDR is required only for toll
outgoing calls.
0:
1:
2:
3:
Metering pulses are necessary. Hexadecimal
assignment is 01.
Example:
b
0
b
1
b
2
b
3
00 0
1
8421
b
0
=bit 0
b
1
=bit 1...
The following explains what hexadecimal data 1 means for SMDR2:
For incoming calls SMDR is required because Bit 0 is assigned as one (1).
SMDR is required for toll and local outgoing calls because Bit 1 is assigned as zero (0).
Metering pulses are detected by the system; therefore Bit 2 is zero (0) and Bit 3 is zero (0).