ND-70917 (E) ISSUE 1 STOCK # 151973 ® Remote PIM System Manual FEBRUARY, 2000 NEC America, Inc.
LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. NEAX is a registered trademark of NEC Corporation. Copyright 2000 NEC America, Inc. Printed in U.S.A.
ISSUE No. ISSUE No. PAGE No. PAGE No.
ISSUE No. ISSUE No. PAGE No. PAGE No.
NEAX2000 IVS2 Remote PIM System Manual TABLE OF CONTENTS Page LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PURPOSE . . . . . . . . . . . . . . . . . . . . .
TABLE OF CONTENTS Page Mounting Line/Trunk Card for E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Failure Transfer (AUC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Failure Transfer (8PFT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONNECTION BETWEEN MAIN SITE AND REMOTE SITE . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIST OF FIGURES Figure Title Figure 1-1 Figure 1-2 Figure 1-3 Figure 1-4 Figure 1-4 Figure 1-5 Figure 2-1 Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 Figure 2-4 Figure 2-5 Figure 2-6 Figure 2-6 Figure 2-7 Figure 2-8 Figure 2-9 Figure 2-10 Figure 2-10 Figure 2-11 Figure 2-12 Figure 2-13 Figure 2-13 Figure 2-14 Figure 2-15 Figure 2-15 Figure 2-16 Figure 2-17 Figure 2-18 Figure 2-19 Figure 2-20 Figure 2-21 Figure 2-22 Figure 2-23 Figure 2-24 Figure 2-25 Figure 2-26 Figure 2-26 Figure 2-27 Figure 2-27 Figure
LIST OF TABLES Table Title Table 1-1 Table 1-2 Table 1-3 Table 1-4 Table 2-1 Table 2-2 Table 3-1 Table 4-1 PIM Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Capacity for T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Capacity for E1 . . . . . . . . . .
INTRODUCTION Purpose INTRODUCTION PURPOSE This manual explains the system outline and installation procedure for providing the Remote PIM to the NEAX2000 IVS2. USING THIS MANUAL This manual contains the following chapters: CHAPTER 1 GENERAL INFORMATION This chapter explains the outline of system configuration, required equipment, system capacity, system conditions, and time slot allocation. CHAPTER 2 INSTALLATION This chapter explains how to install the Remote PIM hardware.
INTRODUCTION Reference Manuals REFERENCE MANUALS Refer to the following manuals during installation: Installation Procedure Manual Provides the installation procedures for the PBX system. Command Manual Describes the Customer Administration Terminal (CAT) operation, command function, and setting data required for programming the PBX system. Office Data Programming Manual Contains the Customer Specification Sheets and Office Data Programming Sheets.
CHAPTER 1 GENERAL INFORMATION This chapter explains the outline of system configuration, required equipment, system capacity, system conditions, and time slot allocation. NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE Remote PIMs can be installed separately at the distance in one building, or between the offices via the Public Switching Telephone Network (PSTN). The customers in the Remote Site can use the same service features as in the Main Site. Remote PIMs are connected to the Main Site by T1 (1.5 Mbps) / E1 (2 Mbps) digital interface. Figure 1-1 Outline of Remote PIM System PIM 1 .
CHAPTER 1 GENERAL INFORMATION PIM Configuration PIM CONFIGURATION One PIM can be installed respectively as a Remote Site. A maximum of three Remote Sites can be provided. The number of Remote Sites determines the number of PIMs in one system. Table 1-1 shows the available PIM configuration for the Remote PIM System.
CHAPTER 1 GENERAL INFORMATION System Configuration SYSTEM CONFIGURATION System Configuration for T1 Figure 1-2 shows the system configuration for T1.
CHAPTER 1 GENERAL INFORMATION System Configuration System Configuration for E1 Figure 1-3 shows the system configuration for E1.
CHAPTER 1 GENERAL INFORMATION Required Equipment REQUIRED EQUIPMENT Table 1-2 shows the required equipment for providing the Remote PIM System. Table 1-2 Required Equipmen t EQUIPMENT FUNCTIONAL NAME NAME FUNCTION PN-DAIA DAI T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Card for Remote PIM Accommodates 24-channel PCM digital lines, and provides Firmware Processor and BUS interface One through three cards must be provided at the Main Site, which corresponds to the number of the Remote Site.
CHAPTER 1 GENERAL INFORMATION Required Equipment Table 1-2 Required Equipment (Continued) EQUIPMENT FUNCTIONAL NAME NAME FUNCTION PN-CP15 FP Firmware Processor Card Provides Line/Trunk interface, Memory (RAM 768 KB), and inter-module BUS interface. BUS interface functions as a driver/receiver of various signals, adjusts gate delay timing and cable delay timing, monitors I/O BUS and PCM BUS.
CHAPTER 1 GENERAL INFORMATION System Capacity SYSTEM CAPACITY System Capacity for T1 Table 1-3 shows the system capacity for T1.
CHAPTER 1 GENERAL INFORMATION System Capacity System Capacity for E1 Table 1-4 shows the system capacity for E1. Table 1-4 System Capacity for E1 DESCRIPTION CAPACITY REMARKS MAIN PIM REMOTE PIM DAID card 3 – DAIE card – 1 DAIF card 3 1 Line/Trunk Ports on Remote Site – 30 Main PIM : 1 DAID Remote PIM: 1 DAIE 60 Main PIM : 1 DAID, 1 DAIF Remote PIM: 1 DAIE, 1 DAIF 1/2 3 3/4 2 5/6 1 7/8 0 NOTE Number of PIM depends on the number of Main PIM and Remote PIM.
CHAPTER 1 GENERAL INFORMATION System Conditions SYSTEM CONDITIONS • Only one PIM configuration is available at the Remote Site. • Remote PIM can be installed at a maximum of 400 m (1312 ft.) distance from the Main Site. Using the Optical Interface card (PN-M10) or line extension equipment (Repeater, MUX, etc.), the distance can be extended. • At the Remote Site, the line/trunk cards can be used as same as the Main Site.
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation TIME SLOT ALLOCATION Time Slot Allocation for T1 One time slot out of the last 24 time slots provided by DAIA-DAIB connection is used for the control signaling channel. Figure 1-4 shows the examples of time slot allocation when mounting 8port cards to the PIM.
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation Figure 1-4 Time Slot Allocation for T1 (2 of 2) (c) When using 1 DAIA card, 1 DAIB card and 4 DAIC cards LT11 LT10 LT09 LT08 LT07 LT06 LT05 LT04 LT03 LT02 LT01 LT00 Remote PIM Highway Channel 00-23 24-47 48-63 DAIC 0 DAIC 1 DAIB • 24 Time Slots for Line/Trunks • 23 Time Slots for Line/Trunks • 1 Time Slot for Control Signaling Channel NOTE • 24 Time Slots for Line/Trunks • Max.
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation Time Slot Allocation for E1 One time slot out of the last 32 time slots provided by DAID-DAIE connection is used for the control signaling channel. Figure 1-5 shows examples of time slot allocation when mounting 8-port cards to the PIM.
This page is for your notes. Page 16 NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 2 INSTALLATION This chapter explains how to install the Remote PIM hardware. This chapter describes only the installation procedures required for the Remote PIM System. Refer to the Installation Procedure Manual for general installation procedures. NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 2 INSTALLATION Precautions PRECAUTIONS Static Electricity Guard You must wear a grounded wrist strap to protect circuit cards from static electricity. Figure 2-1 Static Electricity Guard (1 of 2) • WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD PBX FRAME GROUND SCREW WRIST STRAP • WHEN HOLDING A CIRCUIT CARD NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. CARD FRONT Page 18 NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 2 INSTALLATION Precautions Figure 2-1 Static Electricity Guard (2 of 2) • WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD CIRCUIT CARD WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. • WHEN CARRYING A CIRCUIT CARD CIRCUIT CARD CONDUCTIVE POLYETHYLENE BAG WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN A CONDUCTIVE POLYETHYLENE BAG. The mark shown below is attached to the sheet for the work in which circuit cards are handled.
CHAPTER 2 INSTALLATION Precautions CAUTION You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. PBX NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. CARD FRONT Page 20 NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 2 INSTALLATION Installation Procedure INSTALLATION PROCEDURE Install the Remote PIM System according to the following procedure. Installation Procedure for Main Site Figure 2-2 shows a flowchart of the installation procedure for the Main Site. Figure 2-2 Installation Procedure for Main Site START Mounting DAIA Card for T1 / DAID Card for E1 See Page 23. Mounting DAIC Card for T1 / DAIF Card for E1 See Page 23. Mounting FP Card NOTE 1 See Page 23. Mounting M10 Card NOTE 2 See Page 23.
CHAPTER 2 INSTALLATION Installation Procedure Installation Procedure for Remote Site Figure 2-3 shows a flowchart of the installation procedure for the Remote Site. Figure 2-3 Installation Procedure for Remote Site START Mounting Line/Trunk Card for E1 See Page 35. Mounting DAIB Card for T1 / DAIE Card for E1 See Page 29. Mounting DAIC Card for T1 / DAIF Card for E1 See Page 29. Mounting M10 Card See Page 29. NOTE 1 Mounting Line/Trunk Card for T1 Providing PFT NOTE 2 See Page 31.
CHAPTER 2 INSTALLATION Installation for Main Site INSTALLATION FOR MAIN SITE Mounting DAIA Card for T1 / DAID Card for E1 ATTENTION Contents Static Sensitive Handling Precautions Required (1) Before mounting the DAIA/DAID card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIA/DAID card in the AP slots (AP00-AP11) on the Main Site PIM0, 2, 4. A maximum of three DAIA/DAID cards can be mounted.
CHAPTER 2 INSTALLATION Installation for Main Site BUS Cable Connection (1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as shown in Figure 2-4. In BUS connector on the BWB, BUS1B or BUS0B of the even-numbered PIMs (PIM0, 2, 4, etc.) must be used for this connection.
CHAPTER 2 INSTALLATION Installation for Main Site Figure 2-4 BUS Cable Connection (2 of 2) (b) When mounting DAIA/DAID card on PIM2, PIM4 NOTE When Main PIM is 5 or 6 PIM configuration, the DAIA/DAID card must be mounted on PIM2 and/or PIM4, and connected as follows: BUS1B BUS1A RMT BUS CA-A PIM2 PCM1 PCM0 PIM2/ PIM4 DAIA/ DAID BUS0B BUS0A PIM4 5 PIM PIM2 PIM4 6 PIM NOTE: DAIA/DAID card must be mounted in even-numbered PIMs.
CHAPTER 2 INSTALLATION Installation for Main Site (2) Cable Connection Between DAIA/DAID Cards If two or three DAIA/DAID cards are mounted on one PIM, connect between the PCM0 connector and PCM1 connector on the DAIA/DAID cards by 17-TW-0.3 CONN CA-A, as shown in Figure 2-5. Up to three DAIA/DAID cards can be connected directly by a daisy chain connection on one PIM. Figure 2-5 DAIA/DAID Between DAIA/DAID Cable Connection DAIA/DAID PIM0/ PIM2/ PIM4 PCM1 PCM0 17-TW-0.
CHAPTER 2 INSTALLATION Installation for Main Site (3) Cable Connection Between DAIA/DAID Card and DAIC/DAIF Card Connect between the RBUS connector on the DAIC/DAIF card and the BUS connector on the DAIA/DAID card by 48-TW-0.2 CONN CA, as shown in Figure 2-6. Up to two DAIC cards can be mounted per DAIA card. Only one DAIF card can be mounted per DAID card.
CHAPTER 2 INSTALLATION Installation for Main Site Figure 2-6 DAIA/DAID Between DAIC/DAIF Cable Connection (2 of 2) • When mounting 3 DAIA/DAID cards and 3 DAIC/DAIF cards DAIC DAIA /DAIF /DAID DAIC DAIA /DAIF /DAID DAIC DAIA /DAIF /DAID : 17-TW-0.3 CONN CA-A : 48-TW-0.2 CONN CA TBUS BUS RBUS PCM1 PCM0 • When mounting 3 DAIA cards and 6 DAIC cards DAIC DAIA DAIC Page 28 DAIA DAIC DAIA TBUS BUS RBUS PCM1 PCM0 NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 2 INSTALLATION Installation for Remote Site INSTALLATION FOR REMOTE SITE Mounting DAIB Card for T1 / DAIE Card for E1 ATTENTION (1) Before mounting the DAIB/DAIE card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4. (2) Mount the DAIB/DAIE card in the MP slot on Remote PIM. After mounting the card, set the MB switch to DOWN position.
CHAPTER 2 INSTALLATION Installation for Remote Site BUS Cable Connection Connect between the BUS connector on the DAIB/DAIE card and the RBUS connector on the DAIC/DAIF card by the 48-TW-0.2 CONN CA, as shown in Figure 2-7. Figure 2-7 DAIB/DAIE Between DAIC/DAIF Cable Connection • When mounting 1 DAIC/DAIF card DAIC /DAIF TBUS DAIB /DAIE BUS RBUS 48-TW-0.2 CONN CA • When mounting 2 DAIC cards DAIC DAIC TBUS DAIB BUS RBUS 48-TW-0.
CHAPTER 2 INSTALLATION Installation for Remote Site Mounting Line/Trunk Card for T1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-8 and Table 2-1. Figure 2-8 Mounting Location of Line/Trunk Card for T1 PFT MP12 LT11/FP11 LT10 LT09 LT08 LT07 LT06 LT05 LT04 LT03 LT02 LT01 LT00 VM *1 *2 AC/DC PWR *3 Remote PIM LTC1 LTC0 DC/DC PWR LTC3 LTC2 BWB FRONT *1 When providing only one DAIB card (Max.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-9 Location of Each LEN for T1 • When opposite DAIA card is set to FP No. 1: LEN SLOT No.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-10 LTC Connector Pin Arrangement for T1 (1 of 2) When 8-port card is mounted 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 LTC0 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 LTC1 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 (FP1) (FP2) LEN 200 /400 201 /401 202 /402 203 /403 204 /404 205 /405 2
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-10 LTC Connector Pin Arrangement for T1 (2 of 2) When 8-port card is mounted 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Page 34 LTC2 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 LTC3 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 (FP1) (FP2) LEN 248 /448 249 /449 250 /450 251 /451 252 /452 2
CHAPTER 2 INSTALLATION Installation for Remote Site Mounting Line/Trunk Card for E1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-11 and Table 2-2. Figure 2-11 Mounting Location of Line/Trunk Card for E1 PFT MP12 LT11/FP11 LT10 LT09 LT08 LT07 LT06 LT05 LT04 LT03 LT02 LT01 LT00 VM *1 *2 AC/DC PWR Remote PIM LTC1 LTC0 DC/DC PWR LTC3 LTC2 BWB FRONT *1 When providing only one DAIE card (Max.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-12 Location of Each LEN for E1 • When opposite DAID card is set to FP No. 1: LEN SLOT No.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-13 LTC Connector Pin Arrangement for E1 (1 of 2) When 8-port card is mounted 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 LTC0 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 LTC1 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 (FP1) (FP2) LEN 200 /400 201 /401 202 /402 203 /403 204 /404 205 /405 2
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-13 LTC Connector Pin Arrangement for E1 (2 of 2) When 8-port card is mounted 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Page 38 LTC2 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 LTC3 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 MJ 50 (FP1) (FP2) LEN 248 /448 249 /449 250 /450 251 /451 252 /452 2
CHAPTER 2 INSTALLATION Installation for Remote Site Power Failure Transfer (AUC) The PN-AUC card can be used as the PFT card at the Remote Site. • Figure 2-14 shows an outline of a PFT (PN-AUC) connection. • Figure 2-15 shows the MDF cross connection for a PFT (PN-AUC). Figure 2-14 PFT Connection Outline (AUC) Remote PIM TEL MDF MDF PN-AUC NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.0 TO C.O.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-15 MDF Cross Connection for PFT (AUC) (1 of 2) REMOTE PIM PN-4COT J LTC0 P MDF C.O.R0 1 1 Ring C.O.T0 26 26 Tip C.O.R1 2 2 Ring C.O.T1 27 27 Tip 3 3 28 28 04 4 4 03 29 29 Sta. R0 9 9 Ring Sta. T0 34 34 Tip Sta. R1 10 10 Ring Sta. T1 35 35 Tip LEN000 (No. 0) LEN001 (No. 1) LT00 TO C.O. LINE TO C.O. LINE 02 01 CN1 PN-AUC 4Q-TW-0.3 CONN CA LEN008 (No. 0) LEN009 (No.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-15 MDF Cross Connection for PFT (PN-AUC) (2 of 2) LTC0 (J) LTC0 (P) LEN000 LEN001 1 C.O.R0 26 C.O.T0 2 C.O.R1 27 C.O.T1 26 C.O.T0 1 C.O.R0 27 C.O.T1 2 C.O.R1 LEN008 LEN009 9 Sta.R0 34 Sta.T0 10 Sta.R1 35 Sta.T1 11 36 12 37 34 Sta.T0 9 Sta.R0 35 Sta.T1 10 Sta.R1 36 11 37 12 NOTE 1: The No. 2 and No. 3 circuit in the PN-4COT card cannot be used with the PFT function.
CHAPTER 2 INSTALLATION Installation for Remote Site Power Failure Transfer (8PFT) The PZ-8PFTB card can be used as the PFT card at the Remote Site. • Figure 2-16 shows an outline of a PFT (PZ-8PFTB) connection. Figure 2-16 PFT Connection Outline (8PFT) PZ-8PFTB Remote PIM TEL MDF MDF PN-8LC PN-8COT MDF MDF TO C.O.
CHAPTER 2 INSTALLATION Installation for Remote Site • Install the PZ-8PFTB card to the PIM according to the following steps: (1) (2) Mount the PZ-8PFTB card into the PFT slot of the PIM. Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTB card as shown in Figure 2-27. Figure 2-17 Connection of 25-Pair Cable and PZ-8PFTB PFT1 CONNECTOR CHAMP CONNECTOR ATTACHED TO PZ-8PFTB PZ-8PFTB PFT0 CONNECTOR 25-PAIR CABLE To MDF (See (3) on Page 44.
CHAPTER 2 INSTALLATION Installation for Remote Site (3) Connect the 25-pair cables on the MDF. • Figure 2-18 shows the PFT connector pin assignment for each PFT circuit number (No. 0-No. 7). Figure 2-18 PFT Connector Pin Assignment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Page 44 PFT0 Sta. R0 26 8LC. R0 27 C.O. R0 28 8COT. R0 29 Sta. R1 30 8LC. R1 31 C.O. R1 32 8COT. R1 33 Sta. R2 34 8LC. R2 35 C.O. R2 36 8COT. R2 37 Sta. R3 38 8LC. R3 39 C.O. R3 40 8COT. R3 41 Sta. R4 42 8LC.
CHAPTER 2 INSTALLATION Installation for Remote Site • Figure 2-19 shows an example of the MDF cross connection for the No. 0 circuit on the PFT (PZ-8PFTB). Figure 2-19 MDF Cross Connection for PFT (8PFT) (1 of 2) MDF Tip Ring Tip Ring REMOTE PIM J LTC0 P LEN000 (No. 0) R0 T0 1 26 1 26 LEN001 (No. 1) R1 T1 2 27 2 27 • • • • • • • • • • • • LEN007 (No. 7) R7 T7 8 33 8 33 PN-8COT R0 LEN008 T0 (No. 0) 9 34 9 34 LEN009 (No. 1) R1 T1 10 35 10 35 • • • • • • • • • • • • LEN015 (No.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-20 MDF Cross Connection for PFT (8PFT) (2 of 2) 1 PFT0 CONNECTOR PFT0 (J) 1 2 3 4 2 Sta. R0 8LC. R0 C.O. R0 8COT. R0 26 27 28 29 PFT0 (P) Sta. T0 8LC. T0 C.O. T0 8COT. T0 26 27 28 29 Sta. T0 8LC. T0 C.O. T0 8COT. T0 23 24 25 TO STATION TO PN-8LC TO C.O. LINE TO PN-8COT MJ ALM 48 49 50 PFT1 (P) E –27 V 48 49 50 23 24 25 E –27 V MJ ALM TO PN-DAIB/DAIE TO PZ-PW121 LTC0 CONNECTOR LTC0 (J) Page 46 Sta. R0 8LC. R0 C.O. R0 8COT.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site CONNECTION BETWEEN MAIN SITE AND REMOTE SITE DAI Connection at Main Site (1) When using the LTC connector on the BWB Connect the cable to a CSU or directly to the Remote PIM via the MDF as shown in Figure 2-21. Figure 2-22 shows an example of DAI MDF cross connection. For the optical cable connection between the Main PIM and the Remote PIM, refer to "Optical Cable Connection" on Page 51.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-22 Example of DAI MDF Cross Connection via LTC Connector (Main Site) PIM 0 PN-DAIA/DAID J LTC3 P MDF RECEIVE AP09 RA 1 1 RA RB 26 26 RB TA 2 2 TA TB 27 27 TB 1 SEND LTC3 PN-DAIC/DAIF J P TO CSU/ REMOTE PIM RECEIVE AP10 RA 9 9 RA RB 34 34 RB TA 10 10 TA TB 35 35 TB 2 2 LTC3 CONNECTOR 1 LTC3 CONNECTOR 1 RA 26 RB 26 RB 1 RA 9 RA 34 RB 34 RB 9 RA 2 TA 27 TB 27 TB 2 TA
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site (2) When using the CN connector on the DAI Card Connect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC/DAID/DAIF card as shown in Figure 2-23. Figure 2-23 DAI Cable Connection via CN Connector (Main Site) MAIN PIM BWB DAIA/ DAIC/ DAID/ DAIF MDF CSU CN TWISTED-PAIR CABLE (SHIELD TYPE) REMOTE PIM NOTE Max. 200 m (656 ft.) (0.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site DAI Connection at Remote Site Connect the cable to a CSU or directly to the Main PIM via the CN connector on the DAIB/DAIC/ DAIE/DAIF card as shown in Figure 2-24. Figure 2-24 DAI Cable Connection via CN Connector (Remote Site) REMOTE PIM BWB DAIB/ DAIC/ DAIE/ DAIF MDF CSU CN TWISTED-PAIR CABLE (SHIELD TYPE) MAIN PIM NOTE Max. 200 m (656 ft.) (0.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Optical Cable Connection When using an optical cable to establish the connection between the Main PIM and Remote PIM, connect each end of the cable to the CN1 connector of the M10 cards on both sites. Two DAI cards are connected to one M10 card, via MDF throughLTC connector on the BWB or CN connector on the DAI card. Figure 2-25 through Figure 2-27 show an outline of the connection and an example of the M10 MDF cross connection.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-26 Example of M10 MDF Cross Connection via LTC Connector (Main Site) (1 of 2) PIM 0 PN-DAIA/DAID J LTC3 P MDF RECEIVE AP09 RA 1 1 RA RB TA TB 26 2 27 26 2 27 RB TA TB 1 PN-DAIC/DAIF J SEND LTC3 P RECEIVE AP10 RA 9 9 RA RB TA TB 34 10 35 34 10 35 RB TA TB 2 PN-M10 No. 1 J LTC1 P SEND RECEIVE RA RB 17 42 17 42 RA RB TA TB 18 43 18 43 TA TB SEND LT05 CN1 No.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-26 Example of M10 MDF Cross Connection via LTC Connector (Main Site) (2 of 2) 1 LTC3 CONNECTOR 1 RA 26 RB 26 RB 1 RA 2 TA 27 TB 27 TB 2 TA 3 28 28 3 4 29 29 4 LTC (J) (P) 2 LTC3 CONNECTOR 9 RA 34 RB 34 RB 9 RA 10 TA 35 TB 35 TB 10 TA 11 36 36 11 12 37 37 12 LTC (J) (P) 3 LTC1 CONNECTOR 17 RA 42 RB 42 RB 17 RA 18 TA 43 TB 43 TB 18 TA 19 44 44 19 20 45 45
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-27 Example of M10 MDF Cross Connection via CN Connector (Remote Site) (1 of 2) REMOTE PIM PN-DAIB/DAIE MP12 TB TA RB RA MDF CN RECEIVE 4 3 2 1 TB TA RB RA 1 SEND PN-DAIC/DAIF AP10 TB TA RB RA CN RECEIVE 4 3 2 TB TA RB RA 1 1 PN-M10 No. 1 J LTC1 P SEND RECEIVE RA RB 17 42 17 42 RA RB TA TB 18 43 18 43 TA TB SEND LT05 CN1 No.
CHAPTER 2 INSTALLATION MP Reset Figure 2-27 Example of M10 MDF Cross Connection via CN Connector (Remote Site) (2 of 2) 1 CN CONNECTOR 2 LTC1 CONNECTOR TB TA RB RA 17 RA 42 RB 42 RB 17 RA 18 TA 43 TB 43 TB 18 TA 19 44 44 19 20 45 45 20 LTC (J) (P) MP RESET After mounting all DAI cards/M10 cards and establishing the connection between the Main Site and the Remote Site, press SW1 switch on the MP card. NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
This page is for your notes. Page 56 NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 3 TROUBLESHOOTING This chapter explains the method for fault diagnosis and troubleshooting when maintenance personnel detects fault occurrences by lamp indication on DAIA/DAIB/DAIC/DAID/DAIE/DAIF and M10 cards. For other system faults, refer to the Maintenance Manual. NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 3 TROUBLESHOOTING Table 3-1 shows contents of the faults and the remedial action on each lamp status. Table 3-1 Remedial Action on Each Lamp Status CARD NAME PN-DAIA (DAIA) Page 58 LAMP STATUS RUN lamp is not flashing. FAULT CONTENT Abnormal operation of DAIA card REMEDIAL ACTION 1 Reset the MB switch. (Down→Up→Down) 2 Check the setting of SW1. 1: FP No. 1 2: FP No. 2 3: FP No. 3 0, 4-F: Not used 3 If the fault cannot be cleared, replace the card. LINK lamp is not on.
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME PN-DAIB (DAIB) LAMP STATUS RUN lamp is not flashing. FAULT CONTENT Abnormal operation of DAIB card REMEDIAL ACTION 1 Reset the MB switch. (Down→Up→Down) 2 If the fault cannot be cleared, replace the card. LINK lamp is not on. Layer 2 link connection failure between DAIA and DAIB 1 Check to see if the cable between DAIA and DAIB is correctly connected.
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME PN-DAIC (DAIC) Page 60 LAMP STATUS RUN lamp is not flashing. FAULT CONTENT Abnormal operation of DAIC card REMEDIAL ACTION 1 Reset the MB switch. (Down→Up→Down) 2 If the fault cannot be cleared, replace the card. LINK lamp is not on. Layer 2 link connection failure between DAIA and DAIB 1 Check to see if the cable between DAIA and DAIB is correctly connected.
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME PN-DAID (DAID) LAMP STATUS RUN lamp is not flashing. FAULT CONTENT Abnormal operation of DAID card REMEDIAL ACTION 1 Reset the MB switch. (Down→Up→Down) 2 Check the setting of SW1. 1: FP No. 1 2: FP No. 2 3: FP No. 3 0, 4-F: Not used 3 If the fault cannot be cleared, replace the card. LINK lamp is not on.
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME PN-DAIE (DAIE) Page 62 LAMP STATUS RUN lamp is not flashing. FAULT CONTENT Abnormal operation of DAIE card REMEDIAL ACTION 1 Reset the MB switch. (Down→Up→Down) 2 If the fault cannot be cleared, replace the card. LINK lamp is not on. Layer 2 link connection failure between DAID and DAIE 1 Check to see if the cable between DAID and DAIE is correctly connected.
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME PN-DAIF (DAIF) PN-DAIF (DAIF) LAMP STATUS RUN lamp is not flashing. FAULT CONTENT Abnormal operation of DAIF card REMEDIAL ACTION 1 Reset the MB switch. (Down→Up→Down) 2 If the fault cannot be cleared, replace the card. LINK lamp is not on. Layer 2 link connection failure between DAID and DAIE 1 Check to see if the cable between DAID and DAIE is correctly connected.
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS PN-M10 (M10) CK0 lamp is not on. Cable connection 1 Check to see if the cable failure between Digibetween Digital Trunk Intertal Trunk Interface face and M10 is correctly and No. 0 circuit of connected. M10 2 Check the switch setting of M10. 3 If the fault cannot be cleared, replace the card. CK1 lamp is not on.
CHAPTER 4 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp indications, and the method of switch settings of each circuit card for the Remote PIM. NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 4 CIRCUIT CARD INFORMATION How to Read This Chapter HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system. Explanations are given in alphabetical order of the circuit card names within each circuit card category (Control, Application Processor, and Line/Trunk). (1) Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of each circuit card are shown by a face layout.
CHAPTER 4 CIRCUIT CARD INFORMATION Mounting Location of Circuit Card MOUNTING LOCATION OF CIRCUIT CARD This section explains the conditions for mounting circuit cards for the Remote PIM. Figure 4-1 shows circuit card mounting slots allocated in the PIM.
CHAPTER 4 CIRCUIT CARD INFORMATION List of Required Cards LIST OF REQUIRED CARDS Table 4-1 shows the required cards that are explained in this section.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) PN-CP15 (FP) Locations of Lamps, Switches, and Connectors SENSE RUN MB SW1 Lamp Indications LAMP NAME RUN COLOR Green FUNCTION Flashes at 120 IPM while the circuit card is operating normally NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION SENSE (Rotary SW) FUNCTION CHECK For setting FP No.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) PN-DAIA (DAI) Location of Lamps, Switches, and Connectors SENSE RUN MB LINK RED RMT LOOP PWR BL SW1 SW2 BUS SW3 PCM1 PCM0 JPS JPR CN Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection RED Red Remains lit when detecting PCM signal loss or Fra
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION SENSE (Rotary SW) 3 CHECK FP (Firmware Processor) Number setting for the DAIA card By this setting, the system regards the DAIA card and the opposite DAIB card as one Firmware Processor 1 2 0-F NOTE 1 FUNCTION MB (Toggle SW) 0 Not used 1 FP No. 1 2 FP No. 2 3 FP No. 3 4–F Not used UP For make-busy ON DOWN NOTE 2 SW1 (Piano Key SW) OFF ON For supplying 1.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW2 (DIP SW) ON CHECK ON Control channel signaling data transmission speed: 48 kbps OFF Control channel signaling data transmission speed: 64 kbps ON DTI frame configuration: 12-Multi Frame OFF DTI frame configuration: 24-Multi Frame ON Line code: AMI with ZCS OFF Line code: B8ZS ON Setting of control signal time slot 1 1 2 3 4 5 6 7 8 FUNCTION 2 3 SWITCH NUMBER 4 OFF ON 5 OFF ON 6 OFF ON 7 OF
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW3 (DIP SW) ON 1 2 3 4 ON 1 OFF ON 2 FUNCTION Set the equalizer according to the cable length between the system and the CSU. SW -1 SW -2 SW -3 ON ON ON 0 - 40 m (0 - 131.2 ft.) ON ON OFF 40 - 80 m (131.2 - 262.5 ft.) ON OFF ON 80 - 120 m (262.5 - 394 ft.) ON OFF OFF 120 - 160 m (394 - 525 ft.) OFF ON 160 - 200 m (525 - 656 ft.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) NOTE 3: When the source clock signal is supplied via the line between the Main Site and the Remote Site, set the SW1-1 and SW1-2 as indicated in the following table. In this case, DAIA cards (DAIA0, DAIA1) must be mounted in PIM0. DAIA0 CONDITIONS DAIA1 DAIA2 SW 1-1 SW 1-2 SW 1-1 SW 1-2 SW 1-1 SW 1-2 REMARKS One DAIA card is provided. ON OFF – – – – Clock signal is sent to PLO0 of MP card via Supply Route 0 (DAIA0).
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) PN-DAIB (DAI) Location of Lamps, Switches, and Connectors SENSE RUN MB LINK RED RMT LOOP BL SW1 SW2 BUS SW3 JPS JPR CN Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection RED Red Remains lit when detecting PCM signal loss or Frame Alignment si
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION SENSE (Rotary SW) 0 FUNCTION CHECK Always set to 0 0-F MB (Toggle SW) 1-F Not used UP For make-busy ON DOWN NOTE 1 SW1 (Piano Key SW) OFF For normal operation 1 OFF Always set to OFF 2 OFF Always set to OFF 3 OFF Always set to OFF 4 OFF Always set to OFF 4 3 2 1 ON (Continued) NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW2 (DIP SW) ON CHECK ON Control channel signaling data transmission speed: 48 kbps OFF Control channel signaling data transmission speed: 64 kbps ON DTI frame configuration: 12-Multi Frame OFF DTI frame configuration: 24-Multi Frame ON Line code: AMI with ZCS OFF Line code: B8ZS 1 1 2 3 4 5 6 7 8 FUNCTION 2 3 ON Setting of control signal time slot SWITCH NUMBER 4 OFF ON 5 OFF ON 6 OFF ON 7 OFF
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW3 (DIP SW) ON 1 2 3 4 ON 1 OFF ON 2 FUNCTION Set the equalizer according to the cable length between the system and the CSU. SW -1 SW -2 SW -3 ON ON ON 0 - 40 m (0 - 131.2 ft.) ON ON OFF 40 - 80 m (131.2 - 262.5 ft.) ON OFF ON 80 - 120 m (262.5 - 394 ft.) ON OFF OFF 120 - 160 m (394 - 525 ft.) OFF ON 160 - 200 m (525 - 656 ft.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIC (DAI) PN-DAIC (DAI) Location of Lamps, Switches, and Connectors RUN MB LINK RED RMT LOOP PWR BL SW2 SW1 TBUS SW3 RBUS CN Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when the following connections are normal: • Control channel link between the DAIA card and DAIB card • Connection between the opposite DAIC card Goes out after 15 seconds of link disconnection RED
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIC (DAI) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION MB (Toggle SW) UP FUNCTION CHECK For make-busy ON DOWN NOTE SW1 (Piano Key SW) OFF For normal operation 1 OFF Always set to OFF 2 OFF Always set to OFF 3 OFF Always set to OFF 4 OFF Always set to OFF 1 OFF Not used ON DTI frame configuration: 12-Multi Frame OFF DTI frame configuration: 24-Multi Frame ON Line code: AMI with ZCS OFF Line code: B8ZS 4 OFF Not used 5
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIC (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW3 (DIP SW) ON ON 1 1 2 3 4 FUNCTION CHECK Set the equalizer according to the cable length between the system and the CSU. OFF ON 2 SW -1 SW -2 SW -3 ON ON ON 0 - 40 m (0 - 131.2 ft.) ON ON OFF 40 - 80 m (131.2 - 262.5 ft.) ON OFF ON 80 - 120 m (262.5 - 394 ft.) ON OFF OFF 120 - 160 m (394 - 525 ft.) OFF ON 160 - 200 m (525 - 656 ft.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) PN-DAID (DAI) Location of Lamps, Switches, and Connectors SENSE RUN MB LINK RMT LOOP PWR BL SW1 BUS SW2 SW3 PCM1 PCM0 SRT E1Z JPR JP JPS CN Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection RMT Red Remains lit when receiving the alarm si
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION SENSE (Rotary SW) 3 CHECK FP (Firmware Processor) Number setting for the DAID card By this setting, the system regards the DAID card and the opposite DAIE card as one Firmware Processor. 1 2 NOTE 1 FUNCTION 0-F MB (Toggle SW) 0 Not used 1 FP No. 1 2 FP No. 2 3 FP No. 3 4-F Not used UP For make-busy ON DOWN NOTE 2 SW1 (Piano Key SW) For normal operation ON For supplying 2.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW2 (DIP SW) ON ON Control channel signaling data transmission speed: 48 kbps OFF Control channel signaling data transmission speed: 64 kbps ON CRC Synchronization Detection Timer is provided. OFF CRC Synchronization Detection Timer is not provided. ON CRC4 Check is provided. OFF CRC4 Check is not provided.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW2 (DIP SW) ON FUNCTION Setting of control signal time slot 4 ON SWITCH NUMBER OFF 1 2 3 4 5 6 7 8 ON 5 OFF ON 6 OFF ON 7 OFF ON OFF 8 CHECK 4 5 6 7 8 TIME SLOT NUMBER OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON OFF ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON OFF OFF ON ON ON OFF OFF OF
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) SWITCH NAME SW3 (DIP SW) ON 1 2 3 4 SWITCH SETTING NUMBER POSITION FUNCTION 1 ON Always set to ON 2 ON Always set to ON 3 ON Always set to ON 4 ON Always set to OFF JPS (Jumper Pin) Right Left JPR (Jumper Pin) Right Left E1Z (Jumper Pin) Right Left SRT (Jumper Pin) JP (Jumper Pin) Balanced transmission: 120 ohms (for twisted-pair cable) TA is grounded on the transmission line: 75 ohms (for coaxial cable) Balanced transmission: 120 ohm
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) NOTE 3: When the source clock signal is supplied via the line between the Main Site and the Remote Site, set the SW1-1 and SW1-2 as the following table. In this case, DAID cards (DAID0, DAID1) must be mounted in PIM0. DAID0 CONDITIONS One DAID card is provided. Two or three DAID cards are provided.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) PN-DAIE (DAI) Location of Lamps, Switches, and Connectors SENSE RUN MB LINK RMT LOOP BL SW1 BUS SW2 SW3 JP E1Z JPR JPS CN Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection RMT Red Remains lit when receiving the alarm signal from a distant
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION SENSE (Rotary SW) 0 FUNCTION CHECK Always set to 0 0-F MB (Toggle SW) 1-F Not used UP For make-busy ON DOWN NOTE 1 SW1 (Piano Key SW) OFF For normal operation 1 OFF Always set to OFF 2 OFF Always set to OFF 3 OFF Always set to OFF 4 OFF Always set to OFF ON Control channel signaling data transmission speed: 48 kbps OFF Control channel signaling data transmission speed
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW2 (DIP SW) ON FUNCTION Setting of control signal time slot 4 ON SWITCH NUMBER OFF 1 2 3 4 5 6 7 8 ON 5 OFF ON 6 OFF ON 7 OFF ON OFF 8 CHECK 4 5 6 7 8 TIME SLOT NUMBER OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON OFF ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON OFF OFF ON ON ON OFF OFF OF
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) SWITCH NAME SW3 (DIP SW) ON 1 2 3 4 JPS (Jumper Pin) JPR (Jumper Pin) SWITCH SETTING NUMBER POSITION 1 ON Always set to ON 2 ON Always set to ON 3 ON Always set to ON 4 OFF Always set to OFF Right Balanced transmission: 120 ohms (for twisted-pair cable) Left TA is grounded on the transmission line: 75 ohms (for coaxial cable) Right RA is grounded on the transmission line: 75 ohms (for coaxial cable) Left E1Z (Jumper Pin) Right Left SR
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) PN-DAIF (DAI) Location of Lamps, Switches, and Connectors RUN MB LINK RMT LOOP PWR BL SW2 SW1 TBUS SW3 JPS RBUS JP JPR CN Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when the following connections are normal: • Control channel link between the DAID card and DAIE card • Connection between the opposite DAIF card Goes out after 15 seconds of link disconnection
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) Switch Settings SWITCH NAME SWITCH SETTING NUMBER POSITION MB (Toggle SW) UP FUNCTION CHECK For make-busy ON DOWN NOTE SW1 (Piano Key SW) 1 OFF Always set to OFF ON Line impedance: 75 ohms (for coaxial cable) OFF Line impedance: 120 ohms (for twisted-pair cable) 3 OFF Always set to OFF 4 OFF Always set to OFF OFF 2 4 For normal operation 3 2 1 ON (Continued) Page 94 NEAX2000 IVS2 Remote PIM System Manual ND-70917 (E), Issue 1.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) SWITCH NAME SWITCH SETTING NUMBER POSITION SW2 (DIP SW) ON 1 2 3 4 5 6 7 8 FUNCTION ON Control channel signaling data transmission speed: 48 kbps OFF Control channel signaling data transmission speed: 64 kbps ON CRC Synchronization Detection Timer is provided. OFF CRC Synchronization Detection Timer is not provided. ON CRC4 Check is provided. OFF CRC4 Check is not provided.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) SWITCH NAME SW3 (DIP SW) ON SWITCH SETTING NUMBER POSITION FUNCTION 1 ON Always set to ON 2 ON Always set to ON 3 ON Always set to ON ON When mounting this card on Remote Site.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-M10 (M10) PN-M10 (M10) Location of Lamps, Switches, and Connectors JP3 JP4 CK0 CK1 TALM RALM CN1 JP1 TO OPTICAL CABLE JP2 JP0 Lamp Indications LAMP NAME COLOR FUNCTION CK0 Green Remains lit when a Digital Trunk Interface is connected to No. 0 circuit on this card CK1 Green Remains lit when a Digital Trunk Interface is connected to No.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-M10 (M10) Switch Settings SWITCH NAME JP0, 1 (Jumper Pin) SWITCH SETTING NUMBER POSITION UP When connected to T1 (1.5 M) Digital Trunk Interface Right Line code: B8ZS* is provided. (For T1 interface) *B8ZS: Bipolar Eight Zero Substitution Left JP4 (Jumper Pin) Right Page 98 Line code: B8ZS* is not provided. (For T1 interface) *B8ZS: Bipolar Eight Zero Substitution When connected to E1 (2 M) Digital Trunk Interface Left When connected to T1 (1.