User's Manual

CHAPTER 8 ND-70185 (E)
Page 186
Revision 3.0
EX- FCCS
Data Programming
4.1 Brand-new EX-FCCS Network
To install EX-FCCS network as a brand-new system between two Fusion Groups (when no CCIS data has
been assigned), the overall data programming procedure is as follows.
4.1.1 To Log in to All Nodes in EX-FCCS Network
Assign the following system data for all the nodes in the network. According to the condition of each
node, perform necessary data programming as follows.
STEP 1: ASYD
Assign the Point Code for all the Nodes in the network uniquely. Since Point Code is used to identify each office
in the EX-FCCS network, any identical PCs are not allowed in the same network.
Originating Point Code (OPC) assigned by Indexes 180 and 181:
The OPC is a self-office code, which should be assigned without exception. 14 bits can be used for specifying
OPC. Note that available PC ranges from 1 to 16367 (PCs 16368~16383 are used for Loop Back Test). FPC3
in FUG1 whose OPC is 3, for example, should be assigned as follows.
Miscellaneous Data
Index 186:
b6 must be assigned as 1 (CCIS is in service). The remaining data should be determined depending on custom-
er’s requirements.
Centralized MAT
FCCS
FCCS
FCCS
FCCS
FCCS
FCCS
EX-FCCS
FUG1(Center FUG)
FUG2
PC1
FPC1
PC2
FPC2
PC3
FPC3
PC4
FPC1
PC5
FPC2
PC6
FPC3
NCN1
NCN2
[Example EX-FCCS Network]
<Node which accommodates CCIS Trunk (PC3 in the example)>
b5 b4 b3 b2 b1 b0
000000
b7 b6 b5 b4 b3 b2 b1 b0
00000011
Index 181 Index 180
PC 3
b7 b6 b5 b4 b3 b2 b1 b0
01010011
Example (Index 186)