User's Manual

CHAPTER 8 ND-70185 (E)
Page 196
Revision 3.0
EX- FCCS
Data Programming
2. To Access EX-FCCS Trunk via EX-FCCS Telephone Number
Assign the following data at NCN of the FUG.
STEP 1: AEADN
Assign the ADC (Abbreviate Digit Code) for connection Fusion Group. Enter the FUG Number as-
signed by AFUGN command, TN, and ADC to be assigned.
STEP 2: AELGN
Telephone Numbers must be assigned for all the station within the network uniquely. Use AELGN
command to allocate EX-FCCS Telephone Number. FUG data must be assigned previously by
AFUGN command to activate this command.
Only readout function can be used by this command in case both the Self FUG Number and the Con-
nection FUG Number are assigned, if the Self FUG is not the Center FUG.
Note 1:
Check whether the trunk originating call via CCIS can be executed by dialing EX-FCCS Telephone Number
here. Reexamine the assigned data if the call cannot be connected. There may be some error in data setting
so far.
Note 2:
Refer to the service feature manual for NEAX2000 IVS
2
system as to the data programming on NEAX2000
IVS
2
side.
4.2.3 Upgrading CCIS Network including IVS
2
System to EX-FCCS Network
Enhanced
FUG1
FUG2
FUG3
CCIS
CCIS
CCIS
CCIS
IVS System
IVS System
PC1
PC2
PC3
PC4
PC5
IMX
IMX
IMX
NCN1
NCN2
NCN3
(Center FUG)
2
2
CCIS
Enhanced
CCIS
Enhanced
CCIS
Enhanced
CCIS