====================================================================== Control Commands for NEC Projector (Basic) Rev 06.4.12a Copyright (C) NEC Display Solutions, Ltd. 2002-2012 ---------------------------------------------------------------------Updated on June 4, 2012 ---------------------------------------------------------------------This file contains information about NEC projector control commands.
====================================================================== Contents 1. Projector Control 2. Connection Method 3. Interface Conditions 4. List of Commands 5. Command Descriptions 6. Table of Response Error Codes ====================================================================== 1.
(1) (2) (3-1) (3-2) (3-3) (3-4) Serial Port USB Port Wired LAN Card Wireless LAN Card Wired LAN Port Wireless LAN Port GT5000/GT6000 Yes Yes Yes Yes Yes No GT1150/GT2150 Yes No Yes Yes Yes No HT410/HT510 Yes No No No No No HT1000/HT1100 Yes No No No No No LT180 Yes No No No No No LT25/LT30/LT35 Yes No No No No No LT220/LT240/LT260 Yes No Yes Yes No No LT240K/LT260K Yes Yes Yes Yes No No LT245/LT265/LT280/LT380 Yes No No Yes Yes No MT
* The serial cable, LAN card and LAN cable are separately sold. * The WT610 replaced the WT610 and uses the same command set. (CAUTION) Before making connections, be sure to invalidate the standby mode of the projector and set the "idle mode". The projector cannot use the control commands in the standby mode. Setting method: Under projector [Projector Options] --> [Setup], enter a check for [Idle Mode] on Page 4. ( CAUTION ) (!1) Before making connections, be sure to select [NORMAL] for [STANDBY MODE].
( CAUTION ) Before making connections, set the standby mode of the projector to "NORMAL" or "Idol mode". The projector cannot use the control commands in the power-saving condition, but the following model can use some control commands. Baud rate: Data length: Parity bit: Stop bits: Communications mode: 38400 bps (NP600 series, NP610 Series, VT60/VT70/VT80/VT90 series, VT700: 19200bps) 8 bits No parity 1 bit Full duplex The control connector is described below.
| |<--------------| | +--------------+ Response +--------------+ (ACK or NAK) 4-1. Frame Format ********************************************************************** One frame comprises a header, a data portion, and a checksum. Frame Format: +-------------------------------+----------------------+--------+ | Header portion | Data portion |Checksum| | | (Max.
Entering 00H or FFH becomes a common command for all the projectors. (broadcast notification) This is convenient for controlling multiple projectors at the same time. * When the controller is connected with the projector on a one-to-one basis Broadcast notification is recommended. * When the controller is connected with multiple projectors To control a certain projector, use "individual notification". For all others "broadcast notification" is recommended.
Command : This sets data length of data added to a command to send it. ( See each command description.) Response : This sets data length of data added to a response to send it. ( See each command description.) CAUTION : Data length is specified using total of 12 bits ( 0 - 4095) of 4 bits of the 4th byte and 8 bits of the 5th byte.* The upper ranking 4 bits of the 4th byte is model code. * Data portion This becomes data of data length specified in the data length portion.
03H : Gain-related error 04H : Logo transfer error DATA02 Error description * When not supported 00H : Unknown command 01H : The current model does not support this function. 02H : This model is not compatible with the Switcher. 03H : This model is not compatible with the PC Viewer. * When a parameter error occurs 00H : Unvalid values specified. 01H : Specified terminal is unavailable or cannot be selected 02H : Selected language is not available.
LAN connection ---------------------------------------------------------------------[ Wired LAN port ] LAN interface Communication speed: Auto setting (10/100Mbps) Certified standard: IEEE802.3 (10BASE-T) IEEE802.
039. LAMP MODE SET 046. WXGA MODE SETTING REQUEST 049. WXGA MODE SETTING SET 050. REMOTE KEY CODE 053. LENS CONTROL 053-1. LENS CONTROL REQUEST 053-2. LENS CONTROL 2 053-3. LENS MEMORY CUSTOM SET 053-4. LENS MEMORY REFERENCE SET 053-5. LENS MEMORY CONTROL REQUEST 053-6. LENS MEMORY CONTROL 053-7. LENS INFORMATION REQUEST 060. GAIN PARAMETER REQUEST 2 077. MUTE CONTROL 078-1. SETTING REQUEST 078-2. RUNNING STATUS REQUEST 078-3. INPUT STATUS REQUEST 078-4. MUTE STATUS REQUEST 078-5. MODEL NAME REQUEST 078-6.
29: 30: 31: 32: 33: 34: 35: 36: 37: 38: 39: 40: 41: NP4100/NP4100W (NP4100 Series) NP1250/NP2250/NP3250/NP3250W (NP3250 Series) NP310/NP410W/NP510/NP510W/NP510WS/NP610/NP610S (NP610 Series) NP1200/NP2200 (NP2200 Series) NP110/NP115/NP215/NP216 (NP216 Series) NP43/NP64 (NP64 Series) M260X/M260W/M300X/M300W (M300 Series) P350X/P350X/P420X (P420 Series) U300X/U310W (U300 Series) V260/V260X/V300X (V300 Series) PA600X/PA550W/PA500U/PA500X (PA600 Series) PX700W/PX750U/PX800X (PX750 Series) PH1000U (PH1000 Series
Meaning of Symbols -------------------------------------------------------------------* Supported ! Is available depending on model's version - Not Supported Availability by Model (CURRENT MODELS) Command Name 006. RUNNING SENSE 007. COMMON DATA REQUEST 009. ERROR STATUS REQUEST 015. POWER ON 016. POWER OFF 018. INPUT SW CHANGE 020. PICTURE MUTE ON 021. PICTURE MUTE OFF 022. SOUND MUTE ON 023. SOUND MUTE OFF 024. ONSCREEN MUTE ON 025. ONSCREEN MUTE OFF 030. GAIN ADJUST 030-2.
Availability by Model (LEGACY MODELS) Command Name 006. RUNNING SENSE 007. COMMON DATA REQUEST 009. ERROR STATUS REQUEST 015. POWER ON 016. POWER OFF 018. INPUT SW CHANGE 020. PICTURE MUTE ON 021. PICTURE MUTE OFF 022. SOUND MUTE ON 023. SOUND MUTE OFF 024. ONSCREEN MUTE ON 025. ONSCREEN MUTE OFF 030. GAIN ADJUST 030-2. VOLUME ADJUST Volume Bass Treble Balance 030-12. IMAGE MODE ADJUST Aspect Ratio Input Signal 037. INFORMATION REQUEST 037-1. LAMP INFORMATION REQUEST 037-2. LAMP INFORMATION REQUEST 2 037-4.
This will differ depending on the projector.
Command: 00H 81H 00H 00H 00H 81H Response: At the time of a success 20H 81H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 Status of operation Bit 7: Power On/Off processing 0 = No execution (Normal condition) 1 = During execution Bit 6: Selecting signal processing 0 = No execution (Normal condition) 1 = During execution Bit 5: Cooling processing 0 = No execution (Normal condition) 1 = During execution Bit 4: External cont
DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number - 1) 0 ..
DATA29 Picture mute 00H : OFF 01H : ON DATA30 Sound mute 00H : OFF 01H : ON DATA31 ..
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 ..
Data01 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 03H 03H 03H 04H 04H 04H 04H 05H 05H 06H 06H 08H 08H 08H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 11H 11H 11H 11H 11H 11H 11H 11H 12H 12H 12H 12H 12H 12H 12H 13H 13H 13H 13H 13H 13H 13H 14H 14H 15H 15H 15H 15H 16H 16H 16H 17H 17H 17H 19H Data70 00H 01H 02H 00H 00H 01H 02H 00H 00H 01H 00H 00H 00H 00H 01H 00H 01H 00H 00H 00H 00H 00H 00H 01H 00H 00H 01H 02H 03H 04H 00H 01H 02H 03H 05H 07H 08H 09H 01H 02H 00H 01H 00H 02H 03H 04H 00H 03H 00H 0
DATA72 PC Card insertion 00H : Not inserted 01H : Inserted DATA73 USB Mouse connection 00H : Not connected 01H : Connected DATA74 Entry list type 01H : Default 02H : User DATA75 .. 82 Reserved DATA83 DATA84 DATA85 On-screen mute 00H : OFF 01H : ON Reserved Indicate Contents 00H = Picture signal displaying 01H = No signal 02H = Viewer displaying 03H = Test pattern displaying 04H = LAN displaying DATA86 ..
009. ERROR STATUS REQUEST ********************************************************************** Function: This command acquires the error information occurring with the projector. Command: 00H 88H 00H 00H 00H 88H Response: At the time of a success 20H 88H 01H xxH 0CH DATA01 .. DATA12 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------* The various bits are normal is "0" and error is "1". * "None" is "0" fixation.
Supplement: (!) LT/LT80/HT: "None" 015. POWER ON ********************************************************************** Function: This command switches on the main power of the projector. Command: 02H 00H 00H 00H 00H 02H Response: At the time of a success 22H 00H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on processing. 016.
DATA02 Switching number --------------------------------------------------------When the switching object is the "Signal list", the signal list number is specified. (0…99) --------------------------------------------------------When the switching object is the "Input connector", the input connector number is specified.
Terminal Number Terminal Name 01H 02H 02H 06H 0BH 10H 11H 12H 1AH 1AH 1AH 1FH 20H 07H 0CH 22H 24H 25H 29H 2AH RGB1(RGB) RGB2 (!1) DVI(ANALOG) (!2) Video S-Video Component Component Component DVI (*6) (!2) DVI(DIGITAL)(*6) HDMI Viewer LAN / NETWORK RGB(Video) RGB(S-Video) USB Display SLOT1-1 SLOT1-2 SLOT2-1 SLOT2-2 LEGACY MODELS MT LT LT180 LT80 HT GT W T VT NP1000/3150 HT10 LT30 NP40 * * * * * * * - * * * * * * - * * * * * * * - * * * * * * * * - * * * * * * * - * * * * * * * * * * * * * * * * * *
This command blanks the picture. Command: 02H 10H 00H 00H 00H 12H Response: At the time of a success 22H 10H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * Picture mute is cancelled for the following: Input connector switching Video signal switching 021. PICTURE MUTE OFF ********************************************************************** Function: This command cancels the blank picture condition.
This command cancels the sound muting. Command: 02H 13H 00H 00H 00H 15H Response: At the time of a success 22H 13H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 13H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 024. ONSCREEN MUTE ON ********************************************************************** Function: This command blanks the on-screen display.
*volume increment/decrement *direct setting of brightness *brightness increment/decrement *direct setting of color *color increment/decrement *direct setting of contrast *contrast increment/decrement *direct setting of sharpness *sharpness increment/decrement *direct setting of tint *tint increment/decrement brightness contrast color tint sharpness Not supported "LT170","VT60 series","VT70 series","VT80 series”, “VT90 series" Not supported "HT410/HT510","LT180/LT25/LT30/LT35" volume Not supported "LT17
DATA03 : 01H (increment/decrement) DATA04 : FFH (lower data : -1 = FFFF) DATA05 : FFH (upper data : -1 = FFFF) 030-2. VOLUME ADJUST ********************************************************************** Function: This command sets the volume. Command: 03H 10H 00H 00H 05H DATA01 ..
DATA01 18H DATA03 DATA04 DATA05 DATA02 Adjustment items 00H Aspect Ratio Input (!) Adjustment mode 00H : Absolute value specification 01H : Relative value specification Adjustment value (Lower ranking 8 bits) Adjustment value (Upper ranking 8 bits) Response: At the time of a success 23H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 ..
037. INFORMATION REQUEST ********************************************************************** Function: This command acquires the projector information. Command: 03H 8AH 00H 00H 00H 8DH Response: At the time of a success 23H 8AH 01H xxH 62H DATA01 .. DATA98 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 .. 49 : Projector name (NULL termination character string) DATA50 .. 82 : Reserved DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 ..
(*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 .. 04 : Lamp Hour Meter(Normal mode) (second) DATA05 .. 08 : Reserved DATA09 .. 12 : Lamp Use Warning Starting Time(Normal mode) (second) DATA13 ..
(*1) (*2) (*4) (*3) 037-4. LAMP INFORMATION REQUEST 3 ********************************************************************** Function: This command acquires the information on the projector lamp in Eco mode.
Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to Decimal - value will change to 18000 seconds Lamp's use of hours = 18000/3600 = 5 hours * In case of acquiring the remaining time until lamp warning message starts to appear (in terms of specified values) 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in
DATA02 DATA03 DATA04 DATA05 : Kilogram 9CH 09H 00H 00H : 2460 [kg] DATA06 DATA07 DATA08 DATA09 : Milligram 06H F9H 00H 00H : 63750 [mg] Total Carbon Savings = (2460 * 1000) + (63750 / 1000) = 2460063.75 [g] = 2460 + (63750 / 1000 / 1000) = 2460.06375 [kg] 037-7. LAMP INFORMATION REQUEST 4 ********************************************************************** Function: This command acquires the information on the projector lamp.
A3H 9BH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 9BH 00H 00H 03H 00H 00H 01H CKS Example of acquisition DATA04 DATA05 DATA06 DATA07 : lamp's use of hours 50H 46H 00H 00H : 18000 seconds Lamp Usage = 18000 / 3600 = 5 hour (!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time) Example) The case of Lamp Use Prohibited Time 2100[H] A Lamp Use Warning Starting Time 2000[H] Model.
Data Portion Contents ----------------------------------------------------------------DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of a success 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents ----------------------------------------------------------------DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046.
----------------------------------------------------------------DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of a success 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents ----------------------------------------------------------------DATA01 C3H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) ===================================================================
050. REMOTE KEY CODE ********************************************************************** Function: This command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents ------------------------------------------------------------------DATA01 ..
57 58 59 60 61 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 96 132 133 134 135 136 137 138 158 159 163 164 165 166 167 200 201 214 215 216 217 218 221 222 223 225 226 227 228 229 232 233 237 238 39H 3AH 3BH 3CH 3DH 47H 48H 49H 4AH 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H 55H 60H 84H 85H 86H 87H 88H 89H 8AH 9EH 9FH A3H A4H A5H A6H A7H C8H C9H D6H D7H D8H D9H DAH DDH DEH DFH E1H E2H E3H E4H E5H E8H E9H EDH EEH 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 00H
DATA01 Results 00H : Normal FFH : Error Response: At the time of a failure A2H 0FH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) (!) About AUTO key The MT series model with the built-in image sensor does not support the AUTO key. Use the AUTO (SHORT) key.
Command: 02H 18H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents ------------------------------------------------------------------DATA01 Target 00H : Zoom 01H : Focus DATA02 Contents 00H : Stops 01H : Drives for 1 second in the direction of plus 02H : Drives for 0.5 second in the direction of plus 03H : Drives for 0.25 second in the direction of plus 7FH : Drives in the direction of plus 81H : Drives in the direction of minus FDH : Drives for 0.
(*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 same values as DATA01 of the command DATA02 same values as DATA02 of the command DATA03 Maximum adjustable range (Lower ranking 8 bits) DATA04 Maximum adjustable range (Upper ranking 8 bits) DATA05 Minimum adjustable range (Lower ranking 8 bits) DATA06 Minimum adjustable range (Upper ranking 8 bits) DATA07 Current values (Lower ranking 8 bits) DATA08 Current values (Upper ranking 8 bits) Response:
053-3. LENS MEMORY CUSTOM SET ********************************************************************** Function: This command executes the "Use Custom Point" or "Set Custom Point".
Response: At the time of a failure A2H 1FH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 053-5. LENS MEMORY CONTROL REQUEST ********************************************************************** Function: This command acquires the information on the lens memory function.
DATA01 DATA02 same values as DATA01 of the command Results 00H : Normal 01H : Error Response: At the time of a failure A2H 21H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 060. GAIN PARAMETER REQUEST 2 ********************************************************************** Function: This command acquires the adjustment values. Command: 03H 04H 00H 00H 03H DATA01 .. DATA03 CKS (*3) Data Portion Contents ------------------------------------------------------------------DATA01 ..
(! ) Acquirement items DATA01 00H 01H 02H 03H 04H 05H 05H 05H 06H 06H 06H 06H 06H 07H 08H 08H 09H 09H 0AH 0BH 0CH 0CH 0DH 0DH 0EH 0EH 0FH 0FH 10H 10H 13H 14H 14H 14H 14H 14H 14H 15H 15H 16H 18H 18H 19H 1AH 1BH 1CH 1DH 21H 21H 22H 23H 24H 25H 25H 25H 26H 27H 28H 28H 28H 28H 29H 29H 29H 29H 2AH 2BH 2BH 2CH 2CH DATA02 Acquirement name 00H 00H 00H 00H 00H 00H 01H 02H 00H 01H 02H 03H 04H 00H 00H 01H 00H 01H 00H 00H 00H 01H 00H 01H 00H 01H 00H 01H 00H 01H 00H 00H 01H 02H 03H 04H 05H 00H 01H 00H 00H 01H 00H 00H 0
4CH 4CH 4CH 4CH 4DH 4EH 4EH 4EH 4FH 50H 51H 51H 52H 52H 52H 53H 54H 54H 54H 54H 54H 54H 54H 55H 56H 57H 58H 59H 5AH 5AH 5AH 5AH 5AH 5AH 5AH 5AH 5AH 5BH 5CH 5DH 5EH 5FH 5FH 5FH 5FH 5FH 5FH 5FH 60H 61H 61H 61H 62H 62H 62H 63H 63H 63H 63H 63H 63H 64H 64H 64H 64H 64H 64H 65H 65H 65H 65H 65H 65H 66H 07H 08H 09H 0AH 00H 00H 01H 02H 00H 00H 00H 01H 00H 01H 02H 00H 00H 01H 02H 03H 04H 05H 06H 00H 00H 00H 00H 00H 00H 01H 02H 03H 04H 05H 06H 07H 08H 00H 00H 00H 00H 00H 01H 02H 03H 04H 05H 06H 00H 00H 01H 02H 00H 01H
077. MUTE CONTROL ********************************************************************** Function: This command controls the mute of picture, sound and on-screen.
DATA01 DATA02 DATA03 08H 08H 11H 11H 13H 13H 13H 13H 13H 13H 13H 14H 14H 15H 15H 15H 15H 16H 16H 16H 17H 17H 17H 19H 00H 01H 00H 03H 01H 02H 05H 06H 00H 01H 02H 02H 04H 00H 01H 02H 03H 00H 01H 03H 00H 01H 02H 00H 10H 10H 12H 12H 10H 10H 10H 10H 11H 11H 11H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H Current Models NP4100 NP4100W NP64 NP43 M300X M300W M260X M260W P420X P350X P350W U300X U310W PA600X PA500X PA550W PA500U V300X V260X V260 PX750U PX700W PX800X PH1000U
01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 03H 03H 04H 04H 04H 04H 05H 06H 06H 08H 08H 08H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 11H 11H 11H 11H 11H 11H 11H 12H 12H 12H 12H 12H 12H DATA04 00H 01H 02H 00H 00H 01H 02H 00H 00H 01H 00H 00H 00H 01H 00H 01H 00H 00H 00H 00H 00H 01H 00H 00H 01H 02H 03H 04H 00H 01H 02H 03H 05H 07H 08H 09H 01H 02H 00H 01H 00H 02H 02H 03H 04H 00H 01H 00H 01H 02H 00H 03H 03H 03H 06H 03H 03H 03H 05H 06H 06H 06H 07H 01H 01H 03H 03H 03H 03H 05H 07H 10H 10H 08H 09
DATA05 Calendar function 00H : No function 01H or 03H : Timer function, sleep timer function 02H : Sleep timer function DATA06 .. 32 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 078-2. RUNNING STATUS REQUEST ********************************************************************** Function: This command acquires the status of the projector operation. Command: 00H 85H 00H 00H 01H 01H 87H Response: At the time of a success 20H 85H 01H xxH 10H DATA01 .
(*1) (*2) (*4) (*3) 078-3. INPUT STATUS REQUEST ********************************************************************** Function: This command acquires the status of input signal of the projector. Command: 00H 85H 00H 00H 01H 02H 88H Response: At the time of a success 20H 85H 01H xxH 10H DATA01 ..
01H : Displaying DATA07 ..08 Reserved DATA09 Indicate Contents 00H = Picture signal displaying 01H = No signal 02H = Viewer displaying 03H = Test pattern displaying 04H = LAN displaying DATA10 .. 16 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 078-4. MUTE STATUS REQUEST ********************************************************************** Function: This command acquires the status of the mute of projector.
078-5. MODEL NAME REQUEST ********************************************************************** Function: This command acquires the model name of the projector. Command: 00H 85H 00H 00H 01H 04H 8AH Response: At the time of a success 20H 85H 01H xxH 20H DATA01 .. DATA32 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 ..
Function: This command controls the freeze. Command: 01H 98H 00H 00H 01H DATA01 CKS Operation types DATA01: 00H : Reserved 01H : Freeze start 02H : Freeze cancel Response: At the time of a success 21H 98H ID *0H 01H DATA01 CKS Data Portion Contents ------------------------------------------------------------------DATA01 Results 00H : Normal 01H : Error Response: At the time of a failure A1H 98H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 097-196.
Data Portion Contents ------------------------------------------------------------------DATA01 C5H fixed DATA02 Acquisition Object 00H : MODE 01H : POSITION 02H : SOURCE Response: At the time of a success 23H B0H 01H xxH 03H DATA01 DATA02 DATA03 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 C5H fixed DATA02 Acquisition item(Same as DATA02 of the transmit data) DATA03 Setting Value if DATA02 is MODE(00H) 00H : PIP 01H : SIDE BY SIDE if DATA0
if DATA02 is SOURCE(02H) 00H : OFF 01H : VIDEO 02H : S-VIDEO Response: At the time of a success 23H B1H 01H xxH 03H DATA01 DATA02 DATA03 CKS (*1) (*2) (*3) Data Portion Contents ------------------------------------------------------------------DATA01 00H fixed DATA02 Update target ( Same as DATA02 of the transmit data ) DATA03 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 110.
111. AUTO ADJUST EXECUTE2 ********************************************************************** Function: This command executes the Auto Adjust. Command: 03H BAH 00H 00H 01H 00H BEH Response: At the time of a success 23H BAH 01H xxH 01H 00H CKS (*1) (*2) (*3) Response: At the time of a failure A3H BAH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 305-1. BASE MODEL TYPE REQUEST ********************************************************************** Function: This command acquires the projector type.
DATA02 DATA03 DATA13 DATA14 03H 03H FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH 08H 08H 11H 11H 13H 13H 13H 13H 13H 13H 13H 14H 14H 15H 15H 15H 15H 16H 16H 16H 17H 17H 17H 19H 00H 01H 00H 03H 01H 02H 05H 06H 00H 01H 02H 02H 04H 00H 01H 02H 03H 00H 01H 03H 00H 01H 02H 00H 10H 10H 12H 12H 10H 10H 10H 10H 11H 11H 11H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H Current Models NP4100 NP4100W NP64 NP43 M300X M300W M260X M260W P420X P350X P350W U300X U310W PA
00H 00H 00H 00H 00H 00H 00H 00H 00H 00H 02H 02H 02H 00H 01H 01H 00H 00H 00H 00H 00H 02H 02H 00H 00H 03H 01H FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH FFH 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 02H 02H 02H 03H 03H 03H 04H 04H 04H 05H 05H 05H 05H 06H 06H 08H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 11H 11H 11H 11H 11H 11H 12H 12H 12H 12H 12H 12H 12H 00H 02H 02H 00H 00H 01H 02H 00H 00H 01H 00H 00H 00H 00H 00H 00H 00H 01
DATA15 ... 16 Reserved Response: At the time of a failure A0H BFH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 305-3. PROJECTOR INFORMATION REQUEST ********************************************************************** Function: This command acquires basic operation states of projector. Command: 00H BFH 00H 00H 01H 02H C2H Response: At the time of a success 20H BFH 01H xxH 10H DATA01 ...
0CH : DIGITAL2 0DH : SCART 10H : AUTO FFH : Not Source Input Other : Not Support DATA06 Indication signal type (Effective only when Select source input type 2 is 02H or 03H) x0H : NTSC3.58 x1H : NTSC4.43 x2H : PAL x3H : PAL60 x4H : SECAM x5H : B/W60 x6H : B/W50 x7H : PALNM x8H : NTSC3.58 LBX x9H : NTSC3.
====================================================================== 6.1. Response ---------------------------------------------------------------------* At the time of a success (ACK) This returns ACK without adding data portion to the command that does not request data. This returns ACK with adding data to the data portion for the command that requests data. * At the time of a failure (NAK) This adds a cause of not accepting the command to data portion to return it.