User’s Manual MultiSync P401 MultiSync P461 MultiSync P521 MultiSync P551
Index Declaration of conformity ............................................................................................................................. English-1 Important Information ................................................................................................................................... English-2 WARNING, CAUTION ........................................................................................................................ English-2 Declaration ....................
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions. (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. U.S. Responsible Party: Address: Tel. No.: NEC Display Solutions of America, Inc.
Important Information WARNING TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS THE PRONGS CAN BE FULLY INSERTED. REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, MAKE SURE POWER CORD IS UNPLUGGED FROM WALL SOCKET.
• • • • • FOR OPTIMUM PERFORMANCE, PLEASE NOTE THE FOLLOWING WHEN SETTING UP AND USING THE MULTI-FUNCTION MONITOR: Immediately unplug your monitor from the wall outlet and refer servicing to qualified service personnel under the following conditions: DO NOT OPEN THE MONITOR. There are no user serviceable parts inside and opening or removing covers may expose you to dangerous shock hazards or other risks. Refer all servicing to qualified service personnel.
Contents Your new MultiSync monitor box* should contain the following: • LCD monitor • Cable cover • Power cord*1 • Clamp x 3 • Video Signal Cable • Screw (M4 x 10) x 9 • Wireless Remote Control and AA Batteries • CD-ROM • Setup Manual • Thumbscrew for optional stand x 2*2 Video Signal Cable (Mini D-SUB 15 pin to Mini D-SUB 15 pin) Screw (M4 x 10) x 9 Power Cord*1 Thumbscrew for optional stand x 2*2 Cable cover Setup Manual Clamp x 3 CD-ROM Setup Manual * * Wireless Remote Contr
This device cannot be used or installed without the Tabletop Stand or other mounting accessory for support. For proper installation it is strongly recommended to use a trained, NEC authorized service person. Failure to follow NEC standard mounting procedures could result in damage to the equipment or injury to the user or installer. Product warranty does not cover damage caused by improper installation. Failure to follow these recommendations could result in voiding the warranty.
Attaching Mounting Accessories 3. Ventilation Requirements The display is designed for use with the VESA mounting system. When mounting in an enclosed space or recessed area, leave adequate room between the monitor and the enclosure to allow heat to disperse, as shown below. 1. Attach Mounting Accessories Be careful to avoid tipping monitor when attaching accessories.
English Parts Name and Functions Control Panel POWER button EXIT button Switches the power on/off. See also page 16. Activates the OSD menu when the OSD menu is turned-off. Acts as EXIT button within the OSD to move to previous menu. MUTE button Switches the audio mute ON/OFF. Remote control sensor and Power Indicator INPUT button Acts as SET button within OSD menu.
Terminal Panel L R R, Cr/Pr (OUT) In Out In Out G, Y, VIDEO B, Cb/Pb H V (OUT) (OUT) (OUT) (OUT) Y Cb/Pb L/R (IN1) L L (IN2) (IN3) L (OUT) R (OUT) R, Cr/Pr (IN) G, Y, VIDEO B, Cb/Pb H (IN) (IN) (IN) Main Power Switch V (IN) Cr/Pr R (IN2) R (IN3) VIDEO IN connector (BNC and RCA) On/Off switch to turn main power ON/OFF. To input a composite video signal. BNC and RCA connectors are not available at the same time (Use only one input).
English Kensington Lock For security and theft prevention. EXTERNAL SPEAKER TERMINAL To output the audio signal from AUDIO 1, 2, 3, DPORT, HDMI and TV jack. Red terminal is plus (+). Black terminal is minus (-). Note: This speaker terminal is for 15W + 15W (8 ohm) speaker. Option board slot Slot for board accessories. Please contact your supplier for detailed information.
Wireless Remote Control SOUND button Artificial surround sound. KEYPAD Press buttons to set and change passwords, change channel and set REMOTE ID. ENT button* DISPLAY button Turns on/off the information OSD. See page 18. MENU button Turns on/off the menu mode. AUTO SETUP button Enters auto setup menu. See page 20. EXIT button Returns to previous menu within OSD menu. UP/DOWN button Acts as button to move the highlighted area up or down to select adjustment items within OSD menu.
MTS button* AUDIO INPUT button Selects audio input source [IN1], [IN2], [IN3], [HDMI], [DPORT], [TV]*1, [OPTION]*1. Operating Range for the Remote Control Point the top of the remote control toward the LCD monitor’s remote sensor during button operation. Use the remote control within a distance of about 7 m (23 ft.) from remote control sensor or at a horizontal and vertical angle of within 30° within a distance of about 3.5 m (10 ft.). button Activates closed captioning.
Setup 1. Determine the installation location NEC recommends the following battery use: CAUTION: Installing your LCD display must be done by a qualified technician. Contact your dealer for more information. • Place “AA” size batteries matching the (+) and (-) signs on each battery to the (+) and (-) signs of the battery compartment. • Do not mix battery brands. • Do not combine new and old batteries. This can shorten battery life or cause liquid leakage of batteries.
• Use six of the M4 screws (included) to attach the cable cover. 6. Switch on the power of all the attached external equipment When connected with a computer, switch on the power of the computer first. 7. Operate the attached external equipment Display the signal from the desired input source. 8. Adjust the sound Make volume adjustments when required. 9. Adjust the screen (See pages 20 and 21) Make adjustments of the screen display position when necessary. 10.
Connections NOTE: Do not connect/disconnect cables when turning on the monitor or other external equipment as this may result in a loss of the monitor image. NOTE: Use an audio cable without a built-in resistor. Using an audio cable with a built-in resistor turns down the sound. Before making connections: * First turn off the power of all the attached equipment and make connections. * Refer to the user manual included with each separate piece of equipment.
Connecting your computer to your LCD monitor will enable you to display your computer’s screen image. Some video cards with a pixel clock over 162MHz may not display an image correctly. Your LCD monitor displays proper image by adjusting the factory preset timing signal automatically. Resolution 640 x 480 800 x 600 1024 x 768 1280 x 768 1360 x 768 1280 x 1024 1600 x 1200 1920 x 1080 • Scanning frequency Horizontal Vertical 31.5kHz 60Hz 37.9kHz 60Hz 48.
Basic Operation Power ON and OFF Modes The LCD monitor power indicator will turn green while powered on and will turn red or amber while powered off. NOTE: The Main Power Switch must be in the ON position in order to power up the monitor using the remote control or the Power Button on the front of the LCD.
Mode Power ON Power OFF (Eco Standby)*1 Power consumption under 0.
Information OSD The Information OSD provides information such as: Monitor ID, Input Source, Picture Size, etc. Press the DISPLAY button on the remote to bring up the Information OSD. ID number assigned to current monitor*7 ID number assigned monitor to be controlled via RS-232C*8 Input Name Audio input mode Picture aspect Input Signal Information Sub picture information *7: “IR CONTROL” should be set “Primary” or “Secondary”. *8: “IR CONTROL” should be set “Primary”.
English OSD (On-Screen-Display) Controls NOTE: Some functions may not be available depending on the model or optional equipment. Input source Main Menu Icons Main Menu Item 70 50 50 50 50 50 Sub Menu THANK YOU FOR SAVING THE ENVIRONMENT. CARBON FOOTPRINT 86.0 % PICTURE MODE Select Adjustment Settings Goto Adjustment Return Close Key Guide Press UP or DOWN button to select sub-menu. Press SET. Press UP or DOWN, PLUS or MINUS to select the function or setting to be adjusted. Press MENU or EXIT.
Setting Default PICTURE BRIGHTNESS Adjusts the overall image and background brightness. Press + or - to adjust. Note: When AMBIENT1 or AMBIENT2 is selected in picture mode, this function cannot be changed. 70 CONTRAST Adjusts the image brightness in relationship to the background. Press + or - to adjust. Note: When sRGB is selected in picture mode, this function cannot be changed. 50 SHARPNESS Adjusts the crispness of the image. Press + or - to adjust.
Adjusts the horizontal size of the image. - Adjusts the vertical size of the image. - VGA, RGB/HV inputs only V RESOLUTION VGA, RGB/HV inputs only INPUT RESOLUTION VGA, RGB/HV inputs only If there is a problem with signal detection, this function forces the monitor to display the signal at the desired resolution. After selection, execute “AUTO SETUP” if required. If no problem is detected, the only available option will be “AUTO”. ZOOM MODE Select the aspect ratio of the screen image.
TIME Configures the time for the real-time clock. DAYLIGHT SAVING Configures daylight savings on or off. SCHEDULE RESET Resets the following settings within the SCHEDULE menu back to factory setting: OFF TIMER, SCHEDULE SETTINGS. OFF - PIP KEEP PIP MODE Allows the monitor to remain in “PIP” and “TEXT TICKER” mode after powering off. When Power is returned, PIP and TEXT TICKER appear without having to enter the OSD.
Selects whether the information OSD is displayed or not. The information OSD will be displayed when the input signal or source changes. The information OSD will also give a warning when there is no-signal or the signal is out-of range. An interval between 3 to 10 seconds for the Information OSD to appear is available. MONITOR INFORMATION Monitor Information. CARBON SAVINGS: Display the estimated carbon saving information in kg.
LAN SETTING When you use this function, EXTERNAL CONTROL should be “LAN”. NOTE: When changing the LAN SETTING, turn the monitor off and then back on. After turning on the monitor, you need to wait several seconds until the LAN SETTING is applied. DHCP Enabling this option automatically assigns an IP address to the monitor from your DHCP server. Disabling this option allows you to register the IP address or subnet mask number obtained from your network administrator.
INPUT DETECT All inputs except for TV* Selects the method of input detection the monitor uses when more than two input devices are connected. NONE The Monitor will not search the other video input ports. FIRST DETECT When the current video input signal is not present, then the monitor searches for a video signal from the other video input port. If the video signal is present in the other port, then the monitor switches the video source input port to the new found video source automatically.
COLOR SYSTEM The selected Color System depends on the video format of the input signal. AUTO VIDEO1, VIDEO2, S-VIDEO inputs only AUTO Automatically chooses Color System setting based on input signal. NTSC PAL SECAM 4.43 NTSC PAL-60 SCAN MODE Some video formats may require different scanning modes in order to best display the image. OVER SCAN HDMI, DVD/HD1, DVD/HD2, SCART, VIDEO1, VIDEO2, S-VIDEO, TV* inputs only OVER SCAN Image size is larger than what can be displayed.
English NOTE 1: CREATING A SCHEDULE The schedule function allows the display to be set to power on and off at different times. Up to seven different schedules can be programmed. To program the schedule: 1. Enter the SCHEDULE menu. Highlight SCHEDULE SETTINGS using the up and down buttons. Press the SET or the + button to enter the Settings menu. Highlight the desired schedule number and press set. The box next to the number will turn yellow. The schedule can now be programmed. 2.
Remote Control Function REMOTE CONTROL ID FUNCTION Monitor ID:1 Monitor ID:2 Monitor ID:3 Remote works Remote works Remote works REMOTE CONTROL ID The remote control can be used to control up to 100 individual MultiSync monitors using what is called the REMOTE CONTROL ID mode. The REMOTE CONTROL ID mode works in conjunction with the Monitor ID, allowing control of up to 100 individual MultiSync monitors.
Monitor ID: Displays the ID number of the current monitor within the daisy chain. Target ID: Displays the ID number of the monitor that to be controlled via daisy chain from the current monitor. Press the “+” or “-” buttons to change the “Target ID” to show the ID number of the monitor to be controlled. To control the entire daisy chained monitors simultaneously, select “ALL” as the “Target ID.” 4. Use the wireless remote controller to control the “SECONDARY” monitor while aiming at the “PRIMARY” monitor.
Controlling the LCD monitor via RS-232C Remote Control This LCD monitor can be controlled by connecting a personal computer with a RS-232C terminal. NOTE: When you use this function, EXTERNAL CONTROL should be “RS-232C” (See page 23).
Connecting to a Network Using a LAN cable allows you to specify the Network Settings and the Alert Mail Settings by using an HTTP server function. NOTE: When you use this function, EXTERNAL CONTROL should be “LAN” (See page 23). To use a LAN connection, you are required to assign an IP address. Example of LAN connection: Server NOTE: Use a category 5 or higher LAN cable.
Preparation Before Use Connect the monitor to a commercially available LAN cable before engaging in browser operations. Operation with a browser that uses a proxy server may not be possible depending on the type of proxy server and the setting method. Although the type of proxy server will be a factor, it is possible that items that have actually been set will not be displayed depending on the effectiveness of the cache, and the contents set from the browser may not be reflected in operation.
English Alert Mail Setting http:///lanconfig.html This option notifies your computer of an error message via e-mail when using wired LAN. An error message notification will be sent when an error occurs in the monitor. Alert Mail Checking [ENABLE] will turn on the Alert Mail feature. Checking [DISABLE] will turn off the Alert Mail feature. Host Name Type in the hostname of the network connected to the monitor. Up to 60 alphanumeric characters can be used.
Features Reduced Footprint: Provides the ideal solution for environments with superior image quality. Color Control Systems: Allow you to adjust the colors on your screen and customize the color accuracy of your monitor to a variety of standards. OmniColor: Combines Six-axis color control and the sRGB standard. Six-axis color control permits color adjustments via six axes (R, G, B, C, M and Y) rather than through the three axes (R, G and B) previously available.
No picture • The signal cable should be completely connected to the display card/computer. • The display card should be completely seated in its slot. • Front Power Switch and computer power switch should be in the ON position. • Check to make sure that a supported mode has been selected on the display card or system being used. (Please consult display card or system manual to change graphics mode.) • Check the monitor and your display card with respect to compatibility and recommended settings.
Specifications - P401 Product Specifications LCD Module Pixel Pitch: Resolution: Color: Brightness: Contrast Ratio: Viewing Angle: Design View Distance: Frequency Horizontal: Vertical: 40" /1016 mm diagonal 0.461 mm 1920 x 1080 Over 16 million colors (depending on video card used) 650 cd/m2 (Max.), 500 cd/m2 (Typ.) @25°C 3000:1 89° (typ) @ CR>10 1100 mm 15.625/15.734 kHz, 31.5 kHz - 91.1 kHz (Analog Input) 31.5 kHz - 91.1 kHz (Digital Input) 50.0 - 85.0 Hz Pixel Clock 25.2 MHz - 162.
English Specifications - P461 Product Specifications LCD Module Pixel Pitch: Resolution: Color: Brightness: Contrast Ratio: Viewing Angle: Design View Distance: Frequency Horizontal: Vertical: 46" /1168 mm diagonal 0.530 mm 1920 x 1080 Over 16 million colors (depending on video card used) 650 cd/m2 (Max.), 500 cd/m2 (Typ.) @25°C 4000:1 89° (typ) @ CR>10 1300 mm 15.625/15.734 kHz, 31.5 kHz - 91.1 kHz (Analog Input) 31.5 kHz - 91.1 kHz (Digital Input) 50.0 - 85.0 Hz Pixel Clock 25.2 MHz - 162.
Specifications - P521 Product Specifications LCD Module Pixel Pitch: Resolution: Color: Brightness: Contrast Ratio: Viewing Angle: Design View Distance: Frequency Horizontal: Vertical: 52" /1321 mm diagonal 0.6 mm 1920 x 1080 Over 16 million colors (depending on video card used) 700 cd/m2 (Max.), 500 cd/m2 (Typ.) @25°C 2000:1 89° (typ) @ CR>10 1300 mm 15.625/15.734 kHz, 31.5 kHz - 91.1 kHz (Analog Input) 31.5 kHz - 91.1 kHz (Digital Input) 50.0 - 85.0 Hz Pixel Clock 25.2 MHz - 162.
English Specifications - P551 Product Specifications LCD Module Pixel Pitch: Resolution: Color: Brightness: Contrast Ratio: Viewing Angle: Design View Distance: Frequency Horizontal: Vertical: 54.6"/1388 mm diagonal 0.63 mm 1920 x 1080 Over 16 million colors (depending on video card used) 700 cd/m2 (Max.), 500 cd/m2 (Typ.) @25°C 4000:1 89° (typ) @ CR>10 1300 mm 15.625/15.734 kHz, 31.5 kHz - 91.1 kHz (Analog Input) 31.5 kHz - 91.1 kHz (Digital Input) 50.0 - 85.0 Hz Pixel Clock 25.2 MHz - 162.
Pin Assignment 1) RS-232C input/output Pin No Name 1 connected to 7&8 2 RXD 3 TXD 4 connected to 6 5 GND 6 connected to 4 7 connected to 1&8 8 connected to 1&7 9 NC D-SUB 9P 5 1 6 This LCD monitor uses RXD, TXD and GND lines for RS-232C control.
NEC DISPLAY SOLUTIONS is strongly committed to environmental protection and sees recycling as one of the company’s top priorities in trying to minimize the burden placed on the environment. We are engaged in developing environmentallyfriendly products, and always strive to help define and comply with the latest independent standards from agencies such as ISO (International Organisation for Standardization) and TCO (Swedish Trades Union).