User's Manual

(1/50)
External Control NEC LCD Monitor
1. Application
This document defines the communications method for control of the NEC LCD monitor, MultiSync X461UN
/X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461 /M521 when using
an external controller
.
2. Connectors and wiring
2.1 RS-232C Remote control
Connector: 9-pin D-Sub
Cable: Cross (reversed) cable or null modem cable
(Please refer Controlling the LCD monitor via RS-232C Remote control on Users manual.)
2.2 LAN control
Connector: RJ-45 10/100 BASE-T
Cable: Category 5 or higher LAN cable
(Please refer Controlling the LCD monitor via LAN control on Users manual.)
3. Communication Parameter
3.1 RS-232C Remote control
(1) Communication system Asynchronous
(2) Interface RS-232C
(3) Baud rate 9600bps
(4) Data length 8bits
(5) Parity None
(6) Stop bit 1 bit
(7) Communication code ASCII
3.2 LAN control
(1) Communication system TCP/IP (Internet protocol suite)
(2) Interface Ethernet (CSMA/CD)
(3) Communication layer Transport layer (TCP)
* Using the payload of TCP segment.
(4) IP address (Default) 192.168.0.10
* If you need to change,
Please refer Network settings on Users manual.
(5) Port No. 7142 (Fixed)
(Note)
The monitor will disconnect the connection if no packet data is received for 15 minutes.
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more.
3.3 Communication timing
The controller should wait for a packet interval before next command is sent.
The packet interval needs to be longer than 600msec for the LCD monitor.