External Control NEC LCD Monitor Rev.2.0 (G2) INDEX I. Application ................................................................................ 4 II. Preparation ............................................................................... 5 2. Connectors and wiring .................................................................... 5 2.1 RS-232C Remote control ............................................................... 5 2.2 LAN control ........................................................
8.2 Asset Data write ..................................................................... 50 9. Date & Time read and write .............................................................. 52 9.1 Date & Time Read .................................................................... 52 9.2 Date & Time Write .................................................................... 54 10. Schedule read and write ................................................................ 57 10.1 Schedule Read ....................
20.2 Power Save Mode Write ............................................................. 111 20.3 Auto Power Save Time Read ......................................................... 113 20.4 Auto Power Save Time Write ........................................................ 114 20.5 Auto Standby Time Read ............................................................ 116 20.6 Auto Standby Time Write ............................................................ 117 21. Setting Copy .............................
I. Application This document defines the communications method for control of the NEC LCD monitor, MultiSync P403/ P463 /P553 /P703 /P801 /X464UN /X554UN /X464UNV /X554UNS when using an external controller.
II. Preparation 2. Connectors and wiring 2.1 RS-232C Remote control Connector: 9-pin D-Sub Cable: Cross (reversed) cable or null modem cable (Please refer “Controlling the LCD monitor via RS-232C Remote control” on User’s manual.) 2.
(Please refer “Controlling the LCD monitor via LAN control” on User’s manual.
III. Communication specification 3. Communication Parameter 3.1 RS-232C Remote control (1) (2) (3) (4) (5) (6) (7) Communication system Interface Baud rate Data length Parity Stop bit Communication code Asynchronous RS-232C 9600bps 8bits None 1 bit ASCII 3.2 LAN control (1) Communication system (2) Interface (3) Communication layer (4) IP address (5) Port No. TCP/IP (Internet protocol suite) Ethernet (CSMA/CD) Transport layer (TCP) * Using the payload of TCP segment.
4. Communication Format Header Message Check Code Delimiter The command packet consists of four parts, Header, Message, Check code and Delimiter. Recommended sequence of a typical procedure to control a monitor is as follows, [A controller and a monitor, two-way communication composition figure] ■ For the general command (see the part "6.3.
Header 4.1 Header block format (fixed length) SOH 1st Reserved '0' 2nd Destination 3rd Source Message Message Type 4th 5th Check code Delimiter Message Length 6th -7th 1stbyte) SOH: Start of Header ASCII SOH (01h) 2ndbyte) Reserved: Reserved for future extensions. On this monitor, it must be ASCII '0'(30h). 3rdbyte) Destination: Destination equipment ID. (Receiver) Specify a commands receiver’s address. The controller sets the “MONITOR ID” or “GROUP ID” of the monitor controlled in here.
Ex.) If you want to control a monitor that has the "ID No." as '1', specify a destination address 'A'(41h). If you want to control all of the monitors which are connected by a daisy chain, specify a destination address ‘*’(2Ah). 4thbyte) Source: Source equipment ID. (Sender) Specify a sender address. The controller must be ‘0’ (30h). On the reply, the monitor sets the own MONITOR ID in here. 5thbyte) Message Type: (Case sensitive.) Refer to section 4.2 “Message block format” for more details.
4.2 Message block format Message Header Check code Delimiter “Message block format” is allied to the “Message Type” in the “Header”. Refer to the section 4.1 “Header block format” for more detail. 1)Get current parameter The controller sends this message when you want to get the status of the monitor. For the status that you want to get, specify the “OP code page” and “OP code”, refer to “Appendix A. Operation code table”.
such as “Save current settings”, “Get timing report”, “power control”, “Schedule”, etc. Refer to section 5.5 “Commands message” for more details. 6)Command reply The monitor replies to a query from the controller. “Command reply message” format depends on each command. Refer to section 5.5 “Commands message” for more details.
Header 4.3 Check code Message Check code Delimiter Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH. SOH Reserved Destination Source Type Length(H) Length(L) STX Data | | ETX Check code D0 D1 D2 D3 D4 D5 D6 D7 D8 | | Dn Dn+1 27 26 25 24 23 22 21 20 P P P P P P P P Dn+1 = D1 XOR D2 XOR D3 XOR ,,, Dn XOR: Exclusive OR Following is an example of a Check code (BCC) calculation.
4.4 Delimiter Header Message Check code Packet delimiter code; ASCII CR(0Dh).
5. Message type 5.1 Get current Parameter from a monitor. STX 1st OP code page Hi Lo 2nd-3rd OP code Hi Lo 4th–5th ETX 6th Send this message when you want to get the status of a monitor. For the status that you want to get, specify the “OP code page” the “OP code”, refer to “Appendix A. Operation code table”. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) OP code page: Operation code page. Specify the “OP code page” for the control which you want to get the status.
5.2 "Get parameter" reply STX Result 1st Hi Lo 2nd-3rd OP code page Hi Lo 4th–5th OP code Type Hi Lo 6th –7th Hi Lo 8th -9th Max value MSB 10th -13 th LSB Current Value MSB 14th -17 th LSB ETX 18th The monitor replies with a current value and the status of the requested item (operation code). 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code. These bytes indicate a result of the requested commands as follows, 00h: No Error.
18th byte) ETX: End of Message ASCII ETX (03h) (17/141)
5.3 Set parameter STX 1st OP code page Hi Lo 2nd-3rd OP code Hi Lo 4th-5th Set Value MSB 6th-9th ETX LSB 10th Send this message to change monitor’s adjustment and so on. The controller requests a monitor to change value. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) OP code page: Operation code page This OP code page data must be encoded to ASCII characters. Ex.) The byte data 02h must be encoded to ASCII '0' and '2' (30h and 32h). Refer to the Operation code table.
5.4 "Set parameter" reply STX Result 1st Hi Lo 2nd-3rd OP code page Hi Lo 4th-5th OP code Type Hi Lo 6th-7th Hi Lo 8th-9th Max value MSB 10th -13 th LSB Requested setting Value MSB LSB 14th -17 th The Monitor echoes back the parameter and status of the requested operation code. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code ASCII '0''0' (30h, 30h): No Error.
5.5 Commands "Command message format" depends on each command. Some commands are shown with usage. Refer to section 7 to 13. 5.5.1 Save Current Settings. The controller requests for the monitor to store the adjusted value. STX Command code '0' 'C' ETX Ø Send "OC"(30h, 43h) as Save current settings command.
5.5.2 Get Timing Report and Timing reply. The controller requests the monitor to report the displayed image timing. Command code '0' '7' STX ETX Ø Send "07"(30h, 37h) as Get Timing Report command. Ø Complete "Get Timing Report" command packet as follows; ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'7'-ETX-CHK- CR The monitor replies status as the following format; STX Ø Command '4' 'E' SS Hi H Freq. Lo MSB V Freq.
5.5.3 NULL Message STX Command code 'B' 'E' ETX The NULL message returned from the monitor is used in the following cases; Ø To tell the controller that the monitor does not have any answer to give to the host (not ready or not expected) Ø Following operation s need 15 seconds for to execute, so the monitor will return this message when another message is received during execution.
IV. Control Commands 6. Typical procedure example The following is a sample of procedures to control the monitor, these are examples of "Get parameter", "Set parameter" and "Save current settings". 6.1. How to change the “Backlight” setting. Step 1. The controller requests the Monitor to reply with the current brightness setting and capability to support this operation.
Delimiter CR (0Dh): End of packet Step 3. The controller request the monitor to change the Backlight setting Header SOH-'0'-Monitor ID'0'-'E'-'0'-'A' Message STX-'0'-'0'-'1'-'0''0'-'0'-'5'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'E' (45h): Message Type is "Set parameter command".
Ø Repeat Step 1 and Step 2, if you need to check the Backlight setting. (Recommended) Step 5. Request the monitor to store the Backlight setting. (Save Current Settings Command) Header SOH-'0'-Monitor ID'0'-'A'-'0'-'4' Message STX-'0-'C'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to store the setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
6.2. How to read the measurement value of the built-in temperature sensors. MultiSync P403/ P463 /P553 /P703 /P801 /X464UN /X554UN /X464UNV /X554UNS have three built-in temperature sensors. The controller can monitor inside temperatures by using those sensors with external control. The following shows the procedure for reading the temperatures from the sensors. Step 1. Select a temperature sensor which you want to read.
'7'-'8' (37h, 38h): Operation code is '0'-'0' (30h, 30h): This operation is '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): ETX (03h): End of Message 78h (in the page 2). "Set parameter" type. Number of temperature sensors are 3 (0003h). temperature sensor is #1. Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation. Delimiter CR (0Dh): End of packet Step 3.
Readout value is 2's complement. Temperature [Celsius] +125.0 + 25.0 + 0.5 0 - 0.5 - 25.0 - 55.0 Readout value Binary 0000 0000 1111 0000 0000 0011 0000 0000 0000 0000 0000 0000 1111 1111 1111 1111 1111 1100 1111 1111 1001 1010 0010 0001 0000 1111 1110 0010 Hexadecimal 00FAh 0032h 0001h 0000h FFFFh FFCEh FF92h ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
6.3.
Item OP code page 02h OP code Parameter 23h PICTURE MODE 02h 1Ah RESET (PICTURE) 02h CBh AUTO SETUP 00h 1Eh AUTO ADJUST 10h B7h H POSITION 00h 20h V POSITION 00h 30h CLOCK 00h 0Eh PHASE 00h 3Eh H RESOLUTION 02h 50h V RESOLUTION 02h 51h 0: No mean 1: Off 2: Auto 0: No mean 1: sRGB 3: HIGHBRIGHT 4: STANDARD 5: CINEMA 8: CUSTOM1 9: CUSTOM2 0: No mean 2: Reset Picture category 0: No mean 1: Execute 0: No mean 1: OFF 2: ON 0: Left side | Max.: Right side 0: Bottom side | Max.
Item OP code page 02h INPUT RESOLUTION OP code DAh Parameter Remarks Input Resolution select 0:No mean 1:Item 1(always Auto) 2:Item 2 3:Item 3 4:Item 4 5:Item 5 ASPECT Zoom Control 02h 70h ZOOM 11h 2Ch H ZOOM 11h 2Dh (31/141) Ex) Item 1= AUTO Item 2= -- / 1024x768 / 1400x1050 / 800x600 / 1280x960 Item 3= -- / 1280x768 / 1680x1050 / 1024x576 / 1600x900 / Item 4= -- / 1360x768 / -- / -- / -Item 5= -- / 1366x768 -- / -- / -0: No mean 1: NORMAL 2: FULL 3: WIDE 4: ZOOM 6: DYNAMIC 7: 1:1 0-89(59
OP code Parameter Remarks V ZOOM OP code page 11h 2Eh 0-89(59h): No mean 90(5Ah): 90% 91(5Bh): 91% | 100(64h): 100% | 300(12Ch): 300% The following commands can also be used.
Item OP code page 02h AUDIO INPUT AUDIO DELAY DELAY TIME RESET (AUDIO) OFF TIMER SCHDU LE SCHEDULE ENABLE DISABLE SCHEDULE SETTINGS DATE & TIME DAYLIGHT SAVING RESET (SCHEDULE) KEEP PIP MODE PIP PIP MODE PIP SIZE PIP POSITION X Y ASPECT OP code Parameter 0: No mean 1: IN1 2: IN2 3: IN3 4: HDMI 6: OPTION 7: DPORT 8: DPORT2 9: DPORT3 10(0Ah): HDMI2 10h CAh 0: No mean 1: OFF 2: ON 10h CBh 0: (small) | 100(64h): (large) 02h CBh 0: No mean 4: Reset Audio category 02h 2Bh 0: Off 1: 1 hour | 24(18h
Item OP code Parameter MODE OP code page 10h 08h POSITION 10h 09h SIZE 10h 0Ah BLEND 10h 0Bh DETECT 10h 0Ch FADE IN 10h 0Dh PIP INPUT(SUB INPUT) 02h 73h RESET (PIP) 02h CBh LANGUAGE 00h 68h MENU DISPLAY TIME 00h FCh X 02h 38h Y 02h 39h 0: No mean 1: OFF 2: HORIZONTAL 3: VERTICAL 0: Top/Left | 100(64h): Bottom/Right 0-1: Do not set.
Item OP code page 02h INFORMATION OSD MULTI DIS PLAY MONITOR INFORMATION OP code Parameter MODEL NAME 0:Disable information OSD 3-10(0Ah): OSD timer [seconds] Refer to chapter 12 SERIAL FIRMWARE1 Refer to chapter 12 Refer to chapter 16 FIRMWARE2 Refer to chapter 16 CARBON SAVINGS 10h CARBON USAGE 10h Remarks 3Dh 0 – 999(3E7h)(g) 0 – 65535(FFFFh)(kg) Read Only 0 – 999(3E7h)(g) 0 – 65535(FFFFh)(kg) Read Only OSD TRANSPARENCY 02h 10h (g) /11h (kg) 26h (g) /27h (kg) B8h OSD ROTATION 0
Item TILE MATRIX OP code Parameter MAX VOL OP code page 10h D8h INPUT 10h D9h UNLOCK SELECT 10h DAh 10h DBh 10h DCh H MONITOR 02h D0h V MONITOR 02h D1h POSITION 02h D2h TILE COMP 02h D5h ENABLE 02h D3h FRAME COMP 11h 01h AUTO 11h 02h 0 (whisper) | 100(64h) (laud) 0: No mean 1: UNLOCK 2: LOCK 0: No mean 1: VGA 2: RGB/HV 3: DVI 4: HDMI (Set only) 5: VIDEO 6: VIDEO2 7: S-VIDEO 12(0Ch): Y/Pb/Pr 13(0Dh): OPTION 14(0Eh): Y/Pb/Pr2 (SCART) 15(0Fh): DPORT 16(10h): DPORT2 17(11h)
Item OP code Parameter Remarks V SCAN REVERSE OP code page 11h 04h Available on X464UN, X554UN, X464UNV, X554UNS MANUAL 11h 05h 0: 1: 2: 3: 0: 1: 2: No mean NONE AUTO MANUAL No mean NON REVERSE REVERSE Available on X464UN, X554UN, X464UNV, X554UNS This command is used when V SCAN REVERSE is set as “MANUAL”.
Item OP code page 10h SENSOR1 SENSOR2 SENSOR3 SCREEN SAVER GAMMA BACKLIGHT MOTION INTER VAL ZOOM SIDE BORDER COLOR EXTER NAL CONT ROL CHANGE PASSWORD SECURITY RESET (DISPLAY PROTECTION) IP ADDRESS SETTING MAC ADDRESS LAN POWER DDC/CI PING IP ADDRESS RESET RESET (EXTERNAL CONTROL) ADVAN CED OPTI ON1 INPUT DETECT CUSTOM DETECT PRIORITY1 OP code Parameter E0h: Set centigrade 0 – 65535(FFFFh) E1h: Set offset from max.
Item LONG CABLE COMP INPUT CHANGE TERMINA L SETTING OP code Parameter PRIORITY2 OP code page 10h 2Fh PRIORITY3 10h 30h ON/OFF 10h 3Dh SOG PEAK GAIN R-H. POSITION G-H. POSITION B-H.
Item OP code Parameter DisplayPort OP code page 10h F1h/F2h HDMI SIGNAL 10h 40h DEINTERLACE 02h 25h COLOR SYSTEM 02h 21h OVER SCAN 02h E3h OPTION POWER 10h 41h AUDIO 10h B0h 10h C0h 10h C1h 10h C2h 10h C3h 10h 87h STANDBY 10h C4h PC SOURCE 10h C5h RESET (ADVANCED OPTION1) 02h CBh AUTO DIMMING AUTO BRIGHTNESS 02h 2Dh ROOM LIGHT SENSING 10h C8h BACKLIGHT SETTING 10h C9h Select target DPORT.
Item OP code page 10h OP code Parameter 33h 0 – 100(64h) 10h 34h 0 – 100(64h) 02h B4h 10h 75h ON/OF F 10h DDh BACKL IGHT 10h C6h Current Illuminance read 0: No mean 1: DISABLE 2: AUTO OFF 4: CUSTOM 0: No mean 1: Off 2: On 0: dark | 100(64h): light ON/OF F 10h DEh VOLUM E 10h C7h ON/OF F 10h DFh/D0h INPUT 10h D0h WAITING TIME 10h 78h INTELLI WIRELESS DATA 10h ECh RESET (ADVANCED OPTION2) 02h CBh FACTORY RESET 02h CBh IN BRIGH T IN DARK HUMAN SENSING SENSI NG LUX
Item OP code Parameter INPUT OP code page 00h 60h AUDIO INPUT 02h 2Eh VOLUME UP/DOWN 00h 62h MUTE 00h 8Dh SCREEN MUTE 10h B6h MTS 02h 2Ch SOUND 02h 34h PICTURE MODE 02h 1Ah ASPECT 02h 70h 0: No mean 1: VGA 2: RGB/HV 3: DVI 4: HDMI (Set only) 5: VIDEO 7: S-VIDEO 12(0Ch): Y/Pb/Pr 13(0Dh): OPTION 14(0Eh): Y/Pb/Pr2 (SCART) 15(0Fh): DPORT 16(10h): DPORT2 17(11h): HDMI 18(12h): HDMI2 128(80h): DPORT3 0: No mean 1: IN1 2: IN2 3: IN3 4: HDMI 6: OPTION 7: DPORT 8: DPORT2 9: DPORT3 10(0A
Item OP code page 02h OP code Parameter 72h 0: 1: 2: 3: 4: 5: PIP INPUT 02h 73h STILL CAPTURE 02h 76h SIGNAL INFORMATION 02h EAh AUTO SETUP 00h 1Eh TV-CHANNEL UP/DOWN 00h 8Bh SELECT TEMPERATURE SENSOR 02h 78h 0: 1: 2: 3: READOUT A TEMPERATURE 02h 79h Returned value is 2's complement. Refer to section 6.
7. Power control procedure 7.1 Power status read 1) The controller requests the monitor to reply a current power status. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'6' Message STX-'0'-'1'-'D'-'6'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message Type is "Command".
Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
7.2 Power control 1) The controller requests the monitor to control monitor power. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'C' Message STX-'C'-'2'-'0'-'3'-'D'-'6''0'-'0'-'0'-'1'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command". '0'-'C (30h, 43h): Message length is 12 bytes.
Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
8. Asset Data read and write MultiSync P403/ P463 /P553 /P703 /P801 /X464UN /X554UN /X464UNV /X554UNS have the area for to store user’s asset data of up to 64bytes. 8.1 Asset Data Read Request and reply This command is used in order to read Asset Data. 1) The controller requests the monitor to reply with Asset data.
Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
8.2 Asset Data write This command is used in order to write Asset Data. 1) The controller requests the monitor to write Asset data. Header SOH-'0'-Monitor ID'0'-'A'-N-N Message STX-'C'-'0'-'0'-'E'-'0'-'0'Data(0)-Data(1)---Data(N)-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID in which you want to write data. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
CR (0Dh): End of packet (51/141)
9. Date & Time read and write 9.1 Date & Time Read This command is used in order to read the setting of Date & Time. 1) The controller requests the monitor to reply with the Date & Time. Header Message Check code Delimiter SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'1'-ETX BCC CR '0'-'A'-'0'-'6' Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
'1'-'F'(31h, 46h): 31(=1Fh) WW: weekdays '0'-'0'(30h, '0'-'1'(30h, '0'-'2'(30h, '0'-'3'(30h, '0'-'4'(30h, '0'-'5'(30h, '0'-'6'(30h, 30h): 31h): 32h): 33h): 34h): 35h): 36h): Sunday Monday Tuesday Wednesday Thursday Friday Saturday HH: Hours '0'-'0'(30h, 30h): 0 | '1'-'7'(31h, 37h): 23 (=17h) MN: Minutes '0'-'0'(30h, 30h): 0 | '3'-'B' (33h, 42h): 59 (=3Bh) DS: Daylight saving (Summer time) '0'-'0'(30h, 30h): NO '0'-'1'(30h, 31h): YES ETX (03h): End of Message Check code BCC: Block Check Code Refer to the
9.2 Date & Time Write This command is used in order to write the setting of the Date & Time. 1) The controller requests the monitor to write Date & Time. Header SOH-'0'-Monitor ID'0'-'A'-'1'-'2' Message STX-'C'-'2'-'1'-'2'YY-MM-DD-WW-HH-MN-DS-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change the setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet 2) The monitor replies a data for confirmation. Header Message SOH-'0'-'0'-Monitor IDSTX-'C'-'3'-'1'-'2'-ST'B'-'1'-'6' YY-MM-DD-WW-HH-MN-DS-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply".
Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
10. Schedule read and write 10.1 Schedule Read This command is used in order to read the setting of the Schedule. 1) The controller requests the monitor to read Schedule. Header Message SOH-'0'-Monitor IDSTX-'C'-'2'-'2'-'1'-PG-ETX '0'-'A'-'0'-'8' Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 '3'-'C'(33h, 43h): On timer isn't set. OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): Off timer isn't set.
EXT1: Extension1 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) EXT2: Extension 2 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) EXT3: Extension 3 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) EXT4: Extension 4 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) EXT5: Extension 5 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) EXT6: Extension 6 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) EXT7: Extension 7 '0'-'0'(30h,30h): (On this monitor, it is always ‘00’) ET
***Following command also can be used for to keep backward compatibility, in order to read the setting of the Schedule. 1) The controller requests the monitor to read Schedule. Header Message SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'3'-PG-ETX '0'-'A'-'0'-'8' Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 '3'-'C'(33h, 43h): On timer isn't set. OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): Off timer isn't set. OFF_MIN: Turn off time '0'-'0'(30h, 30h): | '3'-'B'(33h, 42h): '3'-'C'(33h, 43h): (minute) 0 59 (=3Bh) Off timer isn’t set.
10.2 Schedule Write This command is used in order to write the setting of the Schedule. 1) The controller requests the monitor to write Schedule. Header SOH-'0'-Monitor ID'0'-'A'-'2'-'6' Message STX-'C'-'2'-'2'-'2'-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-P MODEEXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
'0'-'E'(30h,45h): Y/Pb/Pr2(SCART) '0'-'F'(30h,46h): DPORT '1'-'0'(31h,30h): DPORT2 '1'-'1'(31h,31h): HDMI '1'-'2'(31h,32h): HDMI2 '8'-'0'(38h,30h): DPORT3 * Please select active input on your system (setting). * If you select inactive input here, the input change execution will be ignored. WD: Week setting bit 0: MONDAY bit 1: TUESDAY bit 2: WEDNESDAY bit 3: THURSDAY bit 4: FRIDAY bit 5: SATURDAY bit 6: SUNDAY EX.
Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies a data for confirmation. Header Message SOH-'0'-'0'-Monitor ID'B'-'2'-'8' STX-'C'-'3'-'2'-'2'-ST-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-P MODEEXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX Check code BCC Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.
'0'-'D'(30h,44h): '0'-'E'(30h,45h): '0'-'F'(30h,46h): '1'-'0'(31h,30h): '1'-'1'(31h,31h): '1'-'2'(31h,32h): '8'-'0'(38h,30h): OPTION Y/Pb/Pr2(SCART) DPORT DPORT2 HDMI HDMI2 DPORT3 WD: Week setting bit 0: MONDAY bit 1: TUESDAY bit 2: WEDNESDAY bit 3: THURSDAY bit 4: FRIDAY bit 5: SATURDAY bit 6: SUNDAY EX.
Delimiter CR (0Dh): End of packet 3) The controller requests the monitor to write Enable/Disable Schedule. Header Message Check code SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'5'-PG-EN-ETX BCC '0'-'A'-'0'-'A' Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
'0'-'1'(30h, 31h): Enable ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
***Following command also can be used for to keep backward compatibility, in order to write the setting of the Schedule. 1) The controller requests the monitor to write Schedule. Header SOH-'0'-Monitor ID'0'-'A'-'1'-'6' Message STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
bit bit bit bit bit 2: 3: 4: 5: 6: WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY EX. '0'-'1'(30h, '0'-'4'(30h, '0'-'F'(30h, '7'-'F'(37h, 31h): 34h): 46h): 46h): MONDAY TUESDAY MONDAY, TUESDAY, WEDNESDAY and THURSDAY MONDAY to SUNDAY FL: Option bit 0: 0:once 1:Everyday bit 1: 0:once 1:Every week bit 2: 0:Disable 1:Enable * When bit 0 and bit 1 are '1', it behaves as Everyday. EX.
'3'-'C'(33h, 43h): On timer isn’t set. OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): Off timer isn't set. OFF_MIN: Turn off time '0'-'0'(30h, 30h): | '3'-'B'(33h, 42h): '3'-'C'(33h, 43h): (minute) 0 59 (=3Bh) Off timer isn’t set.
'A' (41h): Message type is "Command". '0'-'A'(30h, 41h): Message length Message STX (02h): Start of Message 'C'-'2'-'1'-'5' (43h, 32h, 31h, 35h): Enable/Disable Schedule writes command PG-EN: Enable/Disable Schedule data PG: Program No. '0'-'0'(30h, 30h): Program No.1 | '0'-'6'(30h, 36h): Program No.7 EN: Enable /Disable '0'-'0'(30h, 30h): Disable '0'-'1'(30h, 31h): Enable ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
11. Self diagnosis 11.1 Self-diagnosis status read This command is used in order to read the Self-diagnosis status. 1) The controller requests the monitor to read Self-diagnosis status. Header Message Check code Delimiter SOH-'0'-Monitor IDSTX-'B'-'1'-ETX BCC CR '0'-'A'-'0'-'4' Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
'D'-'0'(44h, 30h):D0: PROOF OF PLAY buffer reduction 'E'-'0'(45h, 30h):E0: System error ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
12. Serial No. & Model Name Read 12.1 Serial No. Read This command is used in order to read a serial number. 1) The controller requests the monitor to read a serial number. Header Message Check code SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'6'-ETX BCC '0'-'A'-'0'-'6' Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get serial number. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Note: No null termination character is sent. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
12.2 Model Name Read This command is used in order to read the Model Name. 1) The controller requests the monitor to read Model Name. Header Message Check code SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'7'-ETX BCC '0'-'A'-'0'-'6' Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get Model Name. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
Refer to the section 4.3 “Check code” for a BCC calculation.
13. Security Lock 13.1 Security Lock Control This command sets the condition of security lock function to "LOCK" or "UNLOCK". If security pass codes 1st to 4th are matched with monitor resisted pass codes, then this command is executed, and reply no error status and a new condition. If codes aren't matched with them then setting isn't changed, and reply error status and a current condition.
2) The monitor replies the result to the controller. Header SOH-'0'-'0'-Monitor ID'B'-'0'-'A' Message STX-'C'-'3'-'1'-'D'ST-EN-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply".
14. Direct TV Chanel Read & Write When DTV unit (Option unit) is installed, channel settings is read and write directly. 14.1 Direct TV Chanel Read & Reply 1) The controller requests the monitor to read channel information. Header Message Check code SOH-'0'-Monitor IDSTX-'C'-'2'-'2'-'C'-ETX BCC '0'-'A'-'0'-'6' Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get Model Name. Ex.) If Monitor ID is '1', specify 'A'.
14.2 Direct TV Chanel Write & Reply 1) The controller requests the monitor to write channel information. Header Message Check code Delimiter SOH-'0'-Monitor IDSTX-'C'-'2'-'2'-'D'BCC CR '0'-'A'-'1'-'2' MajorCH-MinorCH-ETX Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get Model Name. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
15. Daylight Saving read & write 15.1 Daylight Saving Read This command is used in order to read the setting of Daylight Saving. 1) The controller requests the monitor to reply a Daylight Saving setting. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'1'-'0'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
LAST : 05h (30h, 35h) BD2: BEGIN DAY2 (Day of the week) SUNDAY : 01h (30h, 31h) MONDAY : 02h (30h, 32h) TUESDAY : 03h (30h, 33h) WEDNESDAY : 04h (30h, 34h) THURSDAY : 05h (30h, 35h) FRIDAY : 06h (30h, 36h) SATURDAY : 07h (30h, 37h) BT1: BEGIN TIME1 (Hour) 00h (30h, 30h) – 23 (32h, 33h) BT2: BEGIN TIME2 (Minute) 00h (30h, 30h) – 59 (35h, 39h) EM: END MONTH JANUARY – DECEMBER: 01h (30h, 31h) - 12h (31h, 32h) ED1: END DAY1 FIRST : 01h (30h, 31h) SECOND : 02h (30h, 32h) THIRD : 03h (30h, 33h) FOUR : 04h (30h, 3
15.2 Daylight Saving Write This command is used in order to write the setting of the Daylight Saving. 1) The controller requests the monitor to write Daylight Saving. Header SOH-'0'-Monitor ID'0'-'A'-'1'-'E' Message STX-'C'-'A'-'0'-'1'-'0'-'1'-BM-BD1-BD2BT1-BT2-EM-ED1-ED2-ET1-ET2-TD-ETX Check code BCC Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
+01:00 : +00:30 : -00:30 : -01:00 : ETX (03h): End 00h (30h, 30h) 01h (30h, 31h) 02h (30h, 32h) 03h (30h, 33h) of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies a written in result. Header Message SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'1'-'0'-'1'-ST-ETX 'B'-'0'-'A' Check code BCC Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller.
16. Firmware Version 16.1 Firmware Version Read This command is used in order to read a firmware version. 1) The controller requests the monitor to reply a firmware version. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'2'-TY-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
00h (30h, 30h) – 09h (30h, 39h) PP: Period: 2Eh (32h, 45h) (fixed) BV1: Minor (Basic) Version1: 00h (30h, 30h) – 09h (30h, 39h) BV2: Minor (Basic) Version2: 00h (30h, 30h) – 09h (30h, 39h) BV3: Minor (Basic) Version3: 00h (30h, 30h) – 09h (30h, 39h) BR1: Branch Version1: A:41h (34h, 31h) – Z:5Ah (35h, 41h) BR2: Branch Version1: A:41h (34h, 31h) – Z:5Ah (35h, 41h) Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
17. Auto ID 17.1 Auto ID Execute This command is used in order to execute Auto ID function. 1) The controller requests the monitor to execute Auto ID function. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'A'-'0'-'1'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (89/141)
17.2 Auto ID Complete This command is used in order to notify complete status of Auto ID. 1) The monitor sends the controller to complete status of Auto ID. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'C' Message STX-'C'-'A'-'0'-'A'-'0'-'2'-ST-MON-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
17.3 Auto ID Reset This command is used in order to reset Auto ID. 1) The controller requests the monitor to reset Auto ID. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'A'-'0'-'3'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
18. Input Name 18.1 Input Name Read This command is used in order to read the setting of Input Name. 1) The controller requests the monitor to reply Input Name setting. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'4'-'0'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Example: 56h 47h 41h -> “VGA” Result: Input Name is “VGA”. Note: No null termination character is sent. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
18.2 Input Name Write This command is used in order to write the setting of Input Name. 1) The controller requests the monitor to write Input Name. Header SOH-'0'-Monitor ID'0'-'A'- LN(H)-LN(L) Message STX-'C'-'A'-'0'-'4'-'0'-1'Data(0)-Data(1)-Data(2)- --- -Data(n)-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
ST: Status 00h (30h, 30h): No Error 01h (30h, 31h): Error ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
18.3 Input Name Reset This command is used in order to reset the Input Name. 1) The controller requests the monitor to reset Input Name. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'4'-'0'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
Delimiter CR (0Dh): End of packet (98/141)
19. Auto Tile Matrix 19.1 Auto Tile Matrix Execute This command is used in order to activate the Auto Tile Matrix Setup. 1) The controller requests the monitor to execute Auto Tile Matrix Header SOH-'0'-Monitor ID'0'-'A'-'1'-'2' Message STX-'C'-'A'-'0'-'3'-'0'-'1'HM-VM-PID-SEL-TMEM-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’. 'B' (42h): Message type is "Command reply".
19.2 Auto Tile Matrix Complete This command is used in order to notify complete status of Auto Tile Matrix Setup. 1) The monitor notifies that Auto Tile Matrix completed to controller. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'A' Message STX-'C'-'A'-'0'-'3'-'0'-'2'-ST-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
Delimiter CR (0Dh): End of packet (102/141)
19.3 Auto Tile Matrix Monitors Read This command is used in order to read the setting of H/V Monitors. 1) The controller requests the monitor to reply H/V Monitors setting. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'3'-'0'-'4'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Refer to the section 4.3 “Check code” for a BCC calculation.
19.4 Auto Tile Matrix Monitors Write This command is used in order to write the setting of H/V Monitors. 1) The controller requests the monitor to write H/V Monitors. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'C' Message STX-'C'-'A'-'0'-'3'-'0'-'5'-HM-VM-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (106/141)
19.5 Auto Tile Matrix Reset This command is used in order to deactivate the Auto Tile Matrix Setup. 1) The controller requests the monitor to reset Auto Tile Matrix Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'3'-'0'-'6'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (108/141)
20. Power Save Mode 20.1 Power Save Mode Read This command is used in order to read the Power Save Mode. 1) The controller requests the monitor to read Power Save Mode Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'B'-0'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (110/141)
20.2 Power Save Mode Write This command is used in order to write the setting of Power Save Mode. 1) The controller requests the monitor to write Power Save Mode. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'A' Message STX-'C'-'A'-'0'-'B'-0'-'1'-MODE-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (112/141)
20.3 Auto Power Save Time Read This command is used in order to read the setting of Auto Power Save Time. 1) The controller requests the monitor to reply Time setting. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'B'-'0'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
20.4 Auto Power Save Time Write This command is used in order to write the setting of Auto Power Save Time. 1) The controller requests the monitor to write Time. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'A' Message STX-'C'-'A'-'0'-'B'-0'-'3'-TIME-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (115/141)
20.5 Auto Standby Time Read This command is used in order to read the setting of Auto Standby Time. 1) The controller requests the monitor to reply Time setting. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'B'-'0'-'4'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
20.6 Auto Standby Time Write This command is used in order to write the setting of Auto Standby Time. 1) The controller requests the monitor to write Time. Header SOH-'0'-Monitor ID-'0''A'-'0'-'A' Message STX-'C'-'A'-'0'-'B'-0'-'5'-TIME-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (118/141)
21. Setting Copy 21.1 Setting Copy Read This command is used in order to read the Setting Copy. 1) The controller requests the monitor to read Setting Copy Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'9'-0'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Bit6: OSD Bit7: MULTI DISP Bit8: PROTECT Bit9: EXT-CTRL Bit10: ADVANCED Bit11: ADVANCED2 Bit12: HTTP Bit13: Reserve Bit14: Reserve Bit15: Reserve Ex.) Setting the following value for T4 Bit0: ALL INPUT is OFF (0). Bit1: PICTURE is OFF (0). Bit2: ADJUST is ON (1). Bit3: AUDIO is ON (1). Step 1: Put above bit in following order. Bit3-Bit2-Bit1-Bit0 Value: 1100 Step 2: Write the value of Step 1 by a hexadecimal number. Value: 0Ch Step 3: Encode the value of Step 2 to ASCII characters.
21.2 Setting Copy Write This command is used in order to write the setting of Setting Copy. 1) The controller requests the monitor to write Setting Copy. Header SOH-'0'-Monitor ID'0'-'A'-'1'-'0' Message STX-'C'-'A'-'0'-'9'-0'-'1'T4-T3-T2-T1-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
2) The monitor replies a written in result. Header Message SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'9'-'0'-'1'-ST-ETX 'B'-'0'-'A' Check code BCC Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’. 'B' (42h): Message type is "Command reply".
21.3 Setting Copy Start This command is used in order to start Setting Copy. 1) The controller requests the monitor to write Setting Copy Start. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'9'-0'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command".
Delimiter CR (0Dh): End of packet (124/141)
22. Security Enable 22.1 Security Enable Read This command is used in order to read the Security Enable. 1) The controller requests the monitor to read Security Enable Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'C'-'0'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
Delimiter CR (0Dh): End of packet (126/141)
22.2 Security Enable Write This command is used in order to write the setting of Security Enable. 1) The controller requests the monitor to set Security password. Header SOH-'0'-Monitor ID'0'-'A'-'1'-'C' Message STX-'C'-'A'-'0'-'C'-'0'-'1'ENA-'0'-'0'-PWD1-…-PWD16-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller.
SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’. 'B' (42h): Message type is "Command reply".
23. LAN MAC Address 23.1 LAN MAC Address Read This command is used in order to read the MAC Address. 1) The controller requests the monitor to read MAC Address Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'2'-'2'-'A'-'0'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller.
In the case of IPv6 -> n = 7 ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 “Check code” for a BCC calculation.
24. Proof of Play 24.1 Start Proof of Play This command is used in order to read Proof of Play log data. 1) The controller requests the monitor to start Proof of Play. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'6'-'0'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller.
Refer to the section 4.3 “Check code” for a BCC calculation.
24.2 Stop Proof of Play This command is used in order to stop Proof of Play log data. 1) The controller requests the monitor to stop Proof of Play. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'6'-'0'-'1'-ETX Check code BCC Delimiter CR Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller. 'A' (41h) : Message Type is "Command".
Delimiter CR (0Dh): End of packet (134/141)
24.3 Get Proof of Play Current This command is used in order to get Proof of Play current log. 1) The controller requests the monitor to get current log of Proof of Play. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'6'-'0'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller.
'0'-'5': VIDEO '0'-'7': S-VIDEO '0'-'C': Y/Pb/Pr '0'-'D': OPTION '0'-'E': Y/Pb/Pr2(SCART) '0'-'F': DPORT '1'-'0': DPORT2 '1'-'1': HDMI '1'-'2': HDMI2 '8'-'0': DPORT3 Data(1)-Data(4) : Check Input Signal '0'-'0'-'0'-'0'-'0'-'0'-'0'-'0' (30h,30h,30h,30h,30h,30h,30h,30h):No signal 'F'-'F'-'F'-'F'-'F'-'F'-'F'-'F' (46h,46h,46h,46h,46h,46h,46h,46h):Invalid signal '*'-'*'-'*'-'*'-'*'-'*'-'*'-'*' (**h,**h,**h,**h,**h,**h,**h,**h):Input signal Ex 1) 1920 x 1080 '0'-'7'-'8'-'0'-'0'-'4'-'3'-'8' : 1920(0780h) x 1080(04
24.4 Get Proof of Play Total Number This command is used in order to get Proof of Play total number. 1) The controller requests the monitor to get the total number of Proof of Play data. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'8' Message STX-'C'-'A'-'0'-'6'-'0'-'3'-ETX Check code BCC Delimiter CR Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller.
Delimiter CR (0Dh): End of packet (138/141)
24.5 Get Proof of Play Number to Number This command is used in order to get Proof of Play number to number log. 1) The controller requests the monitor to get Number to Number log of Proof of Play. Header SOH-'0'-Monitor ID'0'-'A'-'1'-'0' Message STX-'C'-'A'-'0'-'6'-'0'-'4'-BNS(H)BNS(L)-BNE(H)-BNE(L)-ETX Check code BCC Delimiter CR Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Reserved Monitor ID : Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller. 'A' (41h) : Message Type is "Command". '2'-'6' (32h, 36h) : Message length is 38 bytes.
All data are subject to change without notice. (April. 11, 2014) Copyright 2004-2014 NEC Display Solutions, Ltd. All Right Reserved This document provides the technical information for users. NEC Display Solutions, Ltd. reserves the right to change or modify the information contained herein without notice. NEC Display Solutions, Ltd. makes no warranty for the use of its products and bears no responsibility for any errors or omissions which may appear in this document.