Xen IPK Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 NEC Business Solutions Ltd Document No.: 8283 Release 1.
NEC Business Solutions Ltd September 2003 Doc. No.: 8283 - Release 1.
Preface & Disclaimer GENERAL INFORMATION The Xen IPK System is a feature-rich key system that provides over 200 features including Computer Telephony Integration, Least Cost Routing, Automatic Call Distribution, ISDN Trunks and many others. The Xen IPK system meets customer needs today and as business expands the system can be expanded to grow as well. The Xen IPK system has a set of manuals that provide all the information necessary to install and support the system.
September 2003 NEC Business Solutions Ltd NEC shall not be liable for any direct, indirect, consequential or incidental damages about the use of this equipment, manual or any related materials. The information in this technical manual is advisory in nature and is subject to change. NEC may make improvements and changes in the products described in this manual without notice. Changes will be periodically made to the information in the new editions.
Important Note About this Upgrade Procedure This document provides all of the necessary information to upgrade your Xen Axis/Master system to Xen IPK Release 1000 software and to install the related hardware. Doc. No. 8283 - Release 1.0 September 2003 This document is not intended as replacement pages for your current manuals. However, it can be used to supplement those manuals.
September 2003 NEC Business Solutions Ltd Doc. No. 8283 - Release 1.
Table of Contents Preface & Disclaimer................................................................................................... i Important Note About this Upgrade Procedure ..........................................................iii Chapter 1 Xen IPK R1000 Upgrade Procedure for Xen Axis/Master Section 1 Section 2 Section 5 Migration from Xen Axis/Master..........................................................1 - 1 Direct Download from the Installed Xen System ................................
September 2003 NEC Business Solutions Ltd Chapter 4 Programming Call Arrival Key Block Assignment................................................................. 4 - 84 1-13-00 PRI Channel Assignment............................................................................... 4 - 86 1-13-04 PRT B Channel Outgoing Priority Selection .................................................. 4 - 87 1-13-05 PRT B Channel-to-Trunk Group Assignment.................................................
Xen IPK R1000 Upgrade Procedure for Xen Axis/ Master SECTION 1 MIGRATION FROM XEN AXIS/MASTER Chapter 1 Use the following instructions to migrate from an existing Xen Axis/Master system to a Xen IPK R1000 system. The Xen IPK Maintenance Administration Terminal (MAT) software must be used to perform this upgrade. The MIFM-U( ) ETU is required for PC Programming and must be installed.
September 2003 NEC Business Solutions Ltd The following memories are empty after the upgrade: Last Number Redial Memory Recorded messages in the VRS(4)-U( ) ETUs (messages must be recorded again) Store & Repeat/Save & Repeat Select IPK, enter the password, and click OK to open Xen IPK MAT. 4. From the Communications Menu, Select Connect to connect to the Xen Axis/Master system. Doc. No. 8283 - Release 1.0 September 2003 3.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 5. From the Communications menu, select Download and click Start to download the database from the Xen Axis/Master system. 6. When the download is finished, select Save As from the File menu and enter a file name. When the system is to be saved as Xen IPK Basic, confirm that Save As type is Xen IPK Basic (R1000) (*.rdf), and click Save.
September 2003 NEC Business Solutions Ltd From the Communications menu, select Disconnect to disconnect from the Xen system. Doc. No. 8283 - Release 1.0 September 2003 7.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 8. Assign any other required system data assignment changes and from the File menu, select Save if required. 9. Change hardware from the Xen Axis/Master system to the Xen IPK system. Upgrade Type Xen Axis to Xen IPK Basic Port Package Comments Replace the B48-U13 KSU hardware with the following: B64-U23 KSU CPUI( )-U( ) ETU (without PKU 192-UA) ESI(8)-U( ) ETU in slot 1 * Move all other hardware to new KSU.
September 2003 NEC Business Solutions Ltd From the Communications menu, select Connect to connect the Xen IPK. 11. From the Communications menu, select Upload, and click Start. Doc. No. 8283 - Release 1.0 September 2003 10.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 Click Hardware Upload. 13. When Upload is complete, click Close. Doc. No. 8283 - Release 1.0 September 2003 12.
September 2003 NEC Business Solutions Ltd From the Communications menu, Select Disconnect to disconnect from Xen IPK. 15. Reassign all settings recorded in Step 2, and confirm proper system operation. Doc. No. 8283 - Release 1.0 September 2003 14.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 SECTION 3 IMPORT SAVED XEN DATABASE USING A PREVIOUS VERSION OF THE XEN AXIS/ MASTER MAT 1. Verify that the battery is connected to CN4 on Xen Master CPUB( )U( ) or Xen Axis MBD-U( ) Unit. 2.
September 2003 NEC Business Solutions Ltd From the File menu, select Import Xen Axis/Master file to import a previously saved database. 5. Locate the directory where the Xen Axis/Master database is stored. Select file name and click Open to import the database. Doc. No. 8283 - Release 1.0 September 2003 4.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 6. When the download is finished, select Save As from the File menu and enter a file name. When the system is to be saved as Xen IPK Basic, confirm that Save as type is Xen IPK Basic (R1000) (*.rdf), and click Save. When the system is to be saved as Elite IPK Expanded, confirm that Save as type is Xen IPK Expanded (R1000) (*.rdf) and click Save.
September 2003 NEC Business Solutions Ltd 8. Change hardware from the Xen Axis/Master system to the Xen IPK system. Upgrade Type Xen Axis to Xen IPK Basic Port Package Comments Replace the B48-U13 KSU hardware with the following: B64-U23 KSU CPUI( )-U( ) ETU (without PKU 192-UA) ESI(8)-U( ) ETU in slot 1 * Move all other hardware to new KSU.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 From the Communications menu, select Connect to connect to the Xen IPK. 10. From the Communications menu, select Upload, and click Start. Doc. No. 8283 - Release 1.0 September 2003 9.
September 2003 NEC Business Solutions Ltd Click Hardware Upload. 12. When Upload is finished, Click Close. Doc. No. 8283 - Release 1.0 September 2003 11.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 From the Communications menu, select Disconnect to disconnect from the Xen IPK. 14. Reassign all settings recorded in Step 2 and confirm proper system operation. Doc. No. 8283 - Release 1.0 September 2003 13.
September 2003 SECTION 4 UPGRADE PROCEDURE FOR MIFM-U( ) NEC Business Solutions Ltd Upgrade Description This ETU must be upgraded to firmware V5.00 or higher to be compatible with the Xen IPK (R1000) system to support Caller ID Indication – 50 Caller ID scroll buffers N The Caller ID scroll buffers are erased when firmware is upgraded.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 7. Install the MIFM-U( ) into the same slot from Step 1 of the KSU. Figure 1-1: MIFM-U( ) ETU Software Verification for MIFM( )-U( ) ETU Doc. No. 8283 - Release 1.0 September 2003 To verify the current software version installed on the MIFM( )-U( ) ETU do the following: 1. Go off-line. 2. Press LK8 + LK1 to access the Memory Block. 3. Press 4. Verify that the current software revision number is displayed. 5.
September 2003 NEC Business Solutions Ltd SECTION 5 Upgrade Description UPGRADE PROCEDURE FOR PRT(1)-U( ) ETU The PRT(1)-U( ) ETU must be updated to firmware V2.12 or higher to be compatible with the Xen IPK (R1000) system for individual channel assignment and PRT B channel-to-trunk group assignment. Installation Precautions WARNING Observe the following precautions when installing the ETUs to avoid damage to hardware due to static electricity or to being exposed to hazardous voltages.
Enhancement Guide to Migrating from Xen Axis/Master to Xen IPK R1000 4. Install the PRT(1)-U( ) ETU in the KSU. Software Verification To verify that the software revision was installed: 1. Go Off-Line. 2. Press LK8 + LK1. 3. Press 4. Verify that the current software version number is displayed. 5. Press N to locate the PRT(1)-U( ) ETU. Doc. No. 8283 - Release 1.0 September 2003 P to go back On-line.
September 2003 SECTION 6 ADDING AN EARTH CONNECTION NEC Business Solutions Ltd The Xen IPK B64-U23 KSU must be properly and permanently grounded, due to it being an ESELV (Earthed Safety Extra Low Voltage) compliant product. The protective earth terminal located at the right rear corner of the B64-U23 KSU must have a permanent conneciton to protective earth. 1. Connect the gorunding cable (green/yellow wire) to the ground terminal on the right side of the Basic KSU.
Hardware Description and Specifications for Xen IPK 1.1 Chapter 2 B64-U23 KSU 1.1.1 Basic KSU The B64-U23 KSU provides service for outside lines, Attendant Consoles, and interconnection of the station terminals. The B64-U23 KSU has two fixed and eight flexible slots. The first fixed slot is reserved for the CPUI( )U( ) ETU in the basic KSU or for the EXP-U( ) ETU in expansion KSUs. The second fixed slot is for the MIFAU( ) ETU or MIFM-U( ) ETU.
September 2003 NEC Business Solutions Ltd The installation instructions provided in this chapter apply to the basic B64-U23 KSU and the expansion B64-U23 KSUs unless otherwise specified. Figure 2-1: B64-U23 KSU 1.2 CPUI( )-U( ) ETU Description The CPUI( )-U( ) ETU is the Central Processing Unit for the Xen IPK system. This ETU has a Central Processing Unit and a Microprocessing Unit. A 32-bit microprocessor executes the programs stored on the Flash ROM ICs of the MPU unit.
Xen IPK Xen IPK R1000 Upgrade Procedure for Xen Axis/Master Memory Backup Battery (Retains memory for approximately 21 days) Key Function (KF)/Multifunction (MF) Registration Installation Each system must have one CPUI( )-U( ) ETU in the CPU/EXP slot of the basic B64-U23 KSU. Refer to Figure 2-2: CPUI( )-U( ) ETU Switch Settings. W A RN I N G Doc. No. 8283 - Release 1.
September 2003 NEC Business Solutions Ltd Switch Settings Refer to Table 1-1: CPUI( )-U( ) ETU Default Switch Settings.
Xen IPK Xen IPK R1000 Upgrade Procedure for Xen Axis/Master When a CPUI( )-U( ) ETU is installed in the system, the clock/ calendar must be set. This also applies when battery backup fails for any reason. When CPUI( )-U( ) ETU is removed for long term storage, disconnect the battery from CN4. This prevents the battery from discharging completely. The fully charged battery retains memory for approximately 21 days.
September 2003 NEC Business Solutions Ltd 1.3 PKU 192-UA (Port Key Unit) The Port Key Unit allows the system to be configured as an Expanded Port Package. When the PKU 192-UA is not installed, the system is configured as a Basic Port Package; when it is installed, the system is configured as an Expanded Port Package. The PKU 192-UA is installed in the IC30 socket.
Xen IPK Xen IPK R1000 Upgrade Procedure for Xen Axis/Master 1.5 ESIB(8)-U( ) ETU Description The ESIB(8)-U( ) ETU is the basic Electronic Station Interface ETU that provides an 8-channel interface for Multiline Terminals, Attendant Consoles and Single Line Telephone Adapter SLT(1)-U( ) ADP. This ETU can be expanded to 16 channels by installing the ESIE(8)-U( ) ETU. Figure 2-3: ESIB(8)-U( ) ETU Installation A maximum of eight ESIB(8)-U( ) ETUs can be installed in slots S1~S8 in any system KSU. Doc. No.
September 2003 NEC Business Solutions Ltd LED Indications Live LED indications are listed below. Blinking Red Normal Operation Steady Red Operation Stopped (power On) Off No Power LED1 indications are listed below.
Xen IPK Xen IPK R1000 Upgrade Procedure for Xen Axis/Master 1.6 ESIE(8)-U( ) ETU Description The ESIE(8)-U( ) ETU is the expansion Electronic Station Interface ETU that provides an additional 8-channel interface for Multiline Terminals, Attendant Consoles and Single Line Telephone Adapter SLT(1)-U( ) ADP. This expansion ESI ETU is piggybacked on the ESIB(8)-U( ) ETU. Doc. No. 8283 - Release 1.
September 2003 NEC Business Solutions Ltd Connectors The ESIE(8)-U( ) ETU has four connectors: EXCN1 Connects to EXCN1 on the ESIB(8)-U( ) ETU EXCN2 Connects to EXCN2 on the ESIB(8)-U( ) ETU MJ1 Connects to MDF (eight ESI ports) MJ2 Connects to MDF (eight ESI ports) Connections BK RD To MDF GN To Telephone YL RJ-11 Figure 2-6: ESIE(8)-U( ) ETU Connection Pin Assignments The following pin assignments are used to connect eight Multiline Terminals to the ESIE(8)-U( ) ETU.
Xen IPK Xen IPK R1000 Upgrade Procedure for Xen Axis/Master Signal Signal Name Pin Colour 1 T8 CH7–Tip WHT–BLU 2 T7 CH6–Tip BLU–WHT 3 T6 CH5–Tip WHT–ORN 4 R5 CH4–Ring ORN–WHT 5 T5 CH4–Tip WHT–GRN 6 R6 CH5–Ring GRN–WHT 7 R7 CH6–Ring WHT–BRN 8 R8 CH7–Ring BRN–WHT Doc. No. 8283 - Release 1.
September 2003 NEC Business Solutions Ltd Doc. No. 8283 - Release 1.
Features and Specifications for Xen IPK Chapter 3 Attendant Transfer A-15 FEATURE DESCRIPTION Attendant Transfer permits efficient call transfers in the system using an Attendant Multiline Terminal equipped with one to four Attendant Add-On Console(s). Transferred calls can be voice announced, camped-on (when the station is busy), or directly transferred to ring at stations. After a programmed time, all unanswered transferred calls return to the Attendant with distinct audible and visual indications.
September 2003 SERVICE CONDITIONS NEC Business Solutions Ltd General RELATED FEATURES LIST When a Transfer/Camp-On is denied, the call remains on hold at the Attendant Position Multiline Terminal. The outside line key LED flashes green on the station receiving the Transfer/Camp-On, when the line appears on that station. The Large LED also flashes green and the LED or the ANS key flashes red.
Xen IPK Features and Specifications for Xen IPK Call Arrival (CAR) Keys C-3 FEATURE DESCRIPTION Call Arrival (CAR) keys are available software extensions as part of 120 station numbers on the Expanded Port Package. The Basic Port Package provides 32 station numbers and 40 CAR ports. A Call Arrival extension assigned to a line key, can appear and ring on an individual station or multiple stations. When a call is directed to a CAR, any station with the CAR can answer.
September 2003 SERVICE CONDITIONS NEC Business Solutions Ltd General Incoming outside line calls can ring on a CAR. When the call is answered, it resides on a CAP (or CO Line key). The CAR becomes idle for another incoming call or continues to flash when another call is waiting to be answered. When a Call Appearance key (or CO Line key) is unavailable, an outside line call to a Call Arrival key cannot be answered.
Xen IPK Features and Specifications for Xen IPK Basic Port Package Expanded Port Package Basic Terminals (Phones) 32 120 Shared Call Arrival (CAR) Keys with Basic Terminals 24 112 Dedicated Call Arrival (CAR) Keys 40 0 Basic Terminals + Call Arrival (CAR) Keys 72 120 Basic Trunks 16 64 Universal Slot 24 24 Shared MIF Slots with Universal Slots 2 2 Dedicated MIF Slot 1 1 Item RELATED FEATURES LIST Feature Number C-2 Notes Feature Name Call Appearance (CAP) Keys GUIDE TO FEATU
September 2003 NEC Business Solutions Ltd Caller ID - Incoming FEATURE DESCRIPTION C-6 Caller ID displays the calling party telephone number and/or name on the LCD of the Multiline Terminal for CO incoming calls. Up to 16 Multiline Terminals that have CO ringing and/or CAR appearance assigned can automatically display Caller ID information during an incoming call.
Xen IPK Features and Specifications for Xen IPK Manual Operation: For Multiline Terminals without automatic Caller ID display but which have an appropriate class of service assigned, the following key sequences will also display Caller ID indication: Feature key + CO key, Feature key + CAR key, or Feature key + Answer key. Doc. No. 8283 - Release 1.
September 2003 NEC Business Solutions Ltd When the name is not included in the Caller ID information, Memory Block 3-53 (Caller Name Indication Selection) compares the Caller ID information with the dial data in the speed dial area. When the numbers match, the name in the speed dial area is used as the name.
Xen IPK Features and Specifications for Xen IPK General: Doc. No. 8283 - Release 1.0 September 2003 Caller ID Indication Caller ID - Incoming C-6 When the CO line key, CAR key or ANSWER key is flashing red (Incoming CO call), the user can press Feature + Key to display Caller ID even when Caller ID is not normally displayed. When the telephone company sends the caller name and number, the name or the number is displayed on the LCD while the Multiline Terminal is ringing.
September 2003 NEC Business Solutions Ltd The Caller ID Indication disappears: z When an incoming call is answered. z When an internal or ring transfer call is received. z When Feature Access, DSS, Redial, or Feature key is pressed. The Caller ID number is printed on the SMDR printout for incoming calls that are answered at stations that can display Caller ID data. The name is not printed.
Xen IPK Features and Specifications for Xen IPK The DIRE key provided with the Dterm Series i Terminals performs the same function as the Caller ID Scroll key. Caller ID data is not stored when the following conditions apply: Mobile Call from a Mobile Telephone. z Pay Phone Caller ID is sent from a pay phone. z Out of Area Data is sent from a CO that cannot process Caller ID data. z Private Calling party disables Caller ID information for the called party.
September 2003 NEC Business Solutions Ltd GUIDE TO FEATURE PROGRAMMING Order and Shortcut ¶+BS ¶+BS ¶+AI ¶+BTS ¶+BCT ¶+BCT ¶+AI ¶+AI ¶+BTT ¶+BTT ¶+BTM ¶+BTT ¶+BTM ¶+BTM ¶+AI ¶+AI System Data Name Memory Block Card Interface Slot Assignment 7-1 MIF (ANI/Caller ID) Assignment 7-3-04 Caller ID Display Assignment for System Mode 1-1-78 4 Class of Service (Station) Feature Selection 2 1-8-08 DIT Assignment 3-42 ANA Assignment 3-43 Caller ID Display Assignment for CO/PBX Line 3-44 Caller Name
Xen IPK Features and Specifications for Xen IPK Dterm Series i Multiline Terminals D-19 FEATURE DESCRIPTION The Dterm Series i Multiline Terminals provide ergonomic form and userfriendly functions. With advanced digital circuitry, these terminals consist of distinct models to meet users’ diverse telephone terminal needs.
September 2003 OPERATING PROCEDURES NEC Business Solutions Ltd Refer to individual feature for details.
Xen IPK SERVICE CONDITIONS Features and Specifications for Xen IPK General The Dterm Series i Multiline Terminals with an adjustable display offer soft key operation. The LCD panel has three lines of display, each with 24 characters. Standard features include headset jacks, wall mount units, and adjustable-base units. The Dterm Series i Multiline Terminals support dedicated function keys to provide easy one-touch access to the most common telephone operations.
September 2003 NEC Business Solutions Ltd Restrictions For compatibility of Adapter Units and Terminals, refer to the following table: Terminal Adapter Unit DTR-16LD-1A DTR-32D-1A DTR-16D-1A DTR-8D-1A DTR-2DT-1A AD(A)-R( ) X X X X – AP(A)-R( ) X X X X – AP(R)-R( ) X X X X – CT(A)-R( ) X X X X – CT(U)-R( ) X X X X – X X X X – WM-R( ) UNIT X X X X – ACA-U( ) UNIT X X X X – Button Units BS( )-R( ) UNIT Other X = Compatible – = Non-compatible Up to
Xen IPK Features and Specifications for Xen IPK The ACA-U( ) UNIT (AC Adapter) is required when any of the following adapters are installed in a Dterm Series i Multiline Terminal: AP(R)-R( ) z CT(A)-R( ) z CT(U)-R( ) z DCR-60-1A( ) Console z RELATED FEATURES LIST The WM-R( ) UNIT (Wall Mount Unit) is required when any adapter is installed in a Dterm Series i Multiline Terminal and the terminal is to be wall mounted.
September 2003 NEC Business Solutions Ltd DTU-type Multiline Terminal Migration D-20 FEATURES DESCRIPTION DTU-type Multiline Terminal Migration allows an Xen Axis/Master customer to protect their investment in terminals when purchasing Xen IPK system. DTU-type Multiline Terminals can be easily used with the Xen IPK systems. With very few exceptions, all terminal features and abilities that are possible on Xen Axis/Master systems are also possible with the Xen IPK system.
Xen IPK Features and Specifications for Xen IPK RELATED FEATURES LIST Feature Number A-7 D-19 Feature Name Ancillary Device Connection Dterm Series i Multiline Terminals E-2 Electronic Volume Control F-6 Full Duplex Handsfree F-7 Full Handsfree Operation H-3 Handsfree Dialling and Monitoring O-1 Off-Hook Ringing S-9 Softkeys GUIDE TO FEATURE PROGRAMMING Order and Shortcut ¶+BS System Data Name Memory Block 7-2 ¶+BTM Line Key Selection for Telephone Mode 4-12 ¶+BTM Multiline Termi
September 2003 NEC Business Solutions Ltd Electronic Volume Control E-2 FEATURE DESCRIPTION Electronic Volume Control is provided on all Multiline Terminals to allow easy changes to the LCD contrast on Multiline Display Terminals, Off-Hook Ringing volume, Station Ringing volume, and Handset/Station Speaker volume. SYSTEM AVAILABILITY Terminal Type All Multiline Terminals Required Components None OPERATING PROCEDURES To change the LCD contrast for Multiline Display Terminals: P to go off-hook. 1.
Xen IPK Features and Specifications for Xen IPK To change the station ringing volume: P to go off-hook. 1. Press 2. Dial default Access CodeFK. 3. Dial A from the dial pad. 4. Press M while the station is ringing to control ringing volume ( increase or to decrease). ^ to v 5. Go on-hook. To set the handset receiver volume: 1. Go off-hook with the handset. 2. PressM to control handset receiver volume ( decrease). ^ to increase or v to To set the speaker volume: P to go off-hook. 1.
September 2003 NEC Business Solutions Ltd RELATED FEATURE LIST Feature Number Feature Name D-19 Dterm Series i Multiline Terminals D-20 DTU-Type Multiline Terminal Migration F-8 Full Handsfree Operation H-3 Handsfree Dialling and Monitoring O1 Off-Hook Ringing GUIDE TO FEATURE PROGRAMMING Order and Shortcut System Data Name Access Code (1-, 2-, or 3-Digit) Assignment 4 ¶+BTT Receiving Volume Selection 1-1-46/47/ 48 Function 1-8-07 Attendant Page-Line Key 1-8-08 Station PageLine Key
Xen IPK Features and Specifications for Xen IPK External Zone Paging (Meet-Me) E-6 FEATURE DESCRIPTION External Zone Paging (Meet-Me) allows up to three zones of External Zone Paging plus All Zone External Paging. The user can locate personnel quickly using external paging. An external speaker can be installed in a noisy area where a telephone would not be appropriate. All Zone External Paging enables emergency announcements to be made to all areas quickly.
September 2003 NEC Business Solutions Ltd To originate using a Single Line Telephones: 1. Lift the handset. 2. Dial the desired Access Code EE~EI(as set in default) for the required zone. To answer using a Single Line Telephones: SERVICE CONDITIONS 1. Lift the handset. 2. Dial the Meet-Me Access Code (EJ, when the page is an Internal/ External Page, or EL, when the page is only an External Page, as set in default).
Xen IPK Features and Specifications for Xen IPK RELATED FEATURES LIST Feature Number B-1 Feature Name Background Music Over External Speakers GUIDE TO FEATURE PROGRAMMING Order and Shortcut ¶+BS ¶+BA Card Interface Slot Assignment 1-8-08 Station PageLine Key 7-1 Access Code (1-, 2-, or 3-Digit) Assignment 1-1-46/47/ 48 Attendant Add-On Console Key Assignment 1-6-05 External Speaker Connection Selection 1-7-02 External Paging Alert Tone Selection 1-7-03 External Paging Timeout Selection 1-
September 2003 NEC Business Solutions Ltd Full Duplex Handsfree F-6 FEATURE DESCRIPTION The HFU-UA Unit is an add-on device to the DTU-type Multiline Terminals that provides a full duplex speakerphone for small conference rooms. An external microphone is also provided that has a push-to-mute control button that must be held down to turn the microphone off.
Xen IPK Features and Specifications for Xen IPK GUIDE TO FEATURE PROGRAMMING Order and Shortcut ¶+BTM System Data Name 4 HFU Selection Memory Block Function 1-8-07 Attendant Page-Line Key 1-8-08 Station PageLine Key 4-29 Doc. No. 8283 - Release 1.0 September 2003 4 When the system is at default this Memory Block must be programmed for the feature to be used.
September 2003 NEC Business Solutions Ltd ISDN-BRI Trunk Connections FEATURE DESCRIPTION I-7 ISDN-BRI (Integrated Service Digital Network - Basic Rate Interface) is a Public Switched Telephone Network (PSTN) service that provides two B channels (2B + D) for voice call trunking. The B channels are used to provide two CO/PBX type connections. Caller ID is a standard feature on ISDN-BRI provided trunks.
Xen IPK Features and Specifications for Xen IPK Use Memory Block 3-72 (ISDN BRT Connection Configuration) to assign the BRT Interface as Point to Point or Point to Multipoint (default: Point to Multipoint). Use Memory Block 4-47 (ISDN Directory Number Selection) to specify whether or not the directory number is presented to the network. Use Memory Block 4-62 (ISDN DID Directory Number Assignment) to specify per station the outgoing Caller ID Number to be presented.
September 2003 NEC Business Solutions Ltd For BRI firmware version 1.35 or higher, Malicious Call Trace is possible provided the class of service is set in the system and is subscribed with the Telstra Network. If only class of services is set in Xen IPK, activating Malicious Call Trace does not mean it has occurred in the Network. For BRI firmware version 1.63 or higher, access to network Stimulus Mode supplementary services is possible using Keypad mode of operation.
Xen IPK Features and Specifications for Xen IPK Calling Party Number (CPN) Service Order and Shortcut System Data Name Memory Block ¶+BS Card Interface Slot Assignment ¶+BS MIF (Caller ID) Assignment 7-3-04 ¶+ AI Caller ID Display Assignment for System Mode 1-1-78 ¶+BTS 4 Class of Service (Station) Feature Selection 2 1-8-08 ¶+BCT DIT Assignment 3-42 ¶+BCT ANA Assignment 3-43 ¶+ AI Caller ID Display Assignment for CO/PBX Line 3-44 ¶+ AI Caller Name Indication Selection 3-53 ¶+BTT
September 2003 NEC Business Solutions Ltd ISDN-PRI Trunk Connections FEATURE DESCRIPTION I-8 This feature allows the system to connect directly to ESTI Primary Rate ISDN Lines. The PRT(1)-U( ) ETU is required for this facility and allows one connection. Each Primary Rate ISDN connection carries up to 30 channels, providing the system with a total of 30 outside trunks. The use of digital ISDN lines enables voice calls to be made which take advantage of superior voice quality and call security.
Xen IPK SYSTEM AVAILABILITY Features and Specifications for Xen IPK Terminal Type All Stations. Required Components PRT(1)-U( ) ETU CLKG-U( ) Unit Not applicable. SERVICE CONDITIONS Data Assignment for ISDN-PRI Installation Use Memory Block 7-1 (Card Interface Slot Assignment) to select the PRT(1)-U( ) ETU. Doc. No. 8283 - Release 1.
September 2003 NEC Business Solutions Ltd Data Assignment for CO Line Services Use Memory Block 3-52 (ISDN Trunk Directory Number Assignment) to assign the ISDN Directory Number. Use Memory Block 3-91 (Trunk Type Selection) to specify each ISDNPRI trunk as CO Lines. Use Memory Block 4-12 (Line Key Selection for Telephone Mode) to assign the Trunk Appearance, Route Advance Block or CAP key to line keys for each MLT using ISDN-PRI.
Xen IPK Features and Specifications for Xen IPK Data Assignments for Calling Party Number (CPN) Presentation from Station Use Memory Block 4-47 (ISDN Directory Number Selection) to specify whether or not the station is allowed to present the assigned number in Memory Block 4-62 to the network for Caller ID information when trunks are assigned as DID in Memory Block 3-91.
September 2003 NEC Business Solutions Ltd Xen IPK Expanded Eight PRT(1)-U( ) ETUs can be installed in a system. Up to 64 ISDN trunks (B Channels) can be assigned in a system. The PRT(1)-U( ) ETU can be installed in any slot (1-8) in any cabinet (1-3), except when more than 24 channels are assigned in which case a free slot is required to be left to the right of the slot containing the PRT card.
Xen IPK Features and Specifications for Xen IPK GUIDE TO FEATURE PROGRAMMING ISDN – PRI Installation Order and Shortcut System Data Name Memory Block ¶+BS Card Interface Slot Assignment ¶+AD Master Clock Selection 1-8-33 ¶+AN ISDN DTMF Duration/Interdigit Selection 1-1-80 ¶+AN PRT Channel Assignment 1-13-00 ¶+AN PRT B Channel Outgoing Priority Selection 1-13-04 ¶+AN PRT B Channel-to-Trunk Group Assignment 1-13-05 Function 1-8-07 Attendant Page-Line Key 1-8-08 Station Page-Line Key
September 2003 NEC Business Solutions Ltd DID Line Service Order and Shortcut System Data Name Memory Block ¶+BCT 4 Trunk Type Selection 3-91 ¶+ALN Digit Add/Delete for Tie Line Networking Assignment 5-00 ¶+ALN DID Digit Length Selection 1-1-20 ¶+ALN DID Digit Conversion Assignment 1-1-21 ¶+ALN DID Digit Conversion Table 1-1-22 ¶+ALN DID Forward Station Number for Busy Station or Undefined Digit 1-1-23 Function 1-8-07 Attendant Page-Line Key 1-8-08 Station Page-Line Key Function 1
Xen IPK Features and Specifications for Xen IPK Calling Party Number (CPN) Presentation from Station Order and Shortcut ¶+BCT System Data Name Memory Block 3-91 ¶+AN ISDN Directory Number Selection 4-47 ¶+AN 4 ISDN-PRI Directory Number Selection 4-62 1-8-08 Station Page-Line Key Doc. No. 8283 - Release 1.
September 2003 NEC Business Solutions Ltd Music on Hold FEATURE DESCRIPTION M-7 A locally provided music source or an internal music source can be used to supply music to parties on hold, to assure them that they are still connected to the system. System Software allows CO ports to provide multiple music sources to different COs in the system. SYSTEM AVAILABILITY Terminal Type Not applicable Required Components External source connected to the RCA jack on the basic B64-U23 KSU.
Xen IPK Features and Specifications for Xen IPK Internal Source: z Program one of two melodies (American Folk Song melody, or Christmas Song melody) as an internal source. A volume control for the built-in MOH source can also be programmed. External Source: Music source (radio, tape player, or CD) must be provided locally. z Source output levels should be less than 0.6 RMS signal level with 600 Ω impedance. z Optional interface ETUs are not required for this feature.
September 2003 NEC Business Solutions Ltd GUIDE TO FEATURE PROGRAMMING Order and Shortcut ¶+AU Automated Attendant Delay Announcement Hold Tone section 1-4-17 Music on Hold Pattern Selection 1-8-09 Hold Tone Source Assignment 1-8-31 Hold Internal Tone Volume Selection 1-8-32 CO External Source Selection 3-11 CO External Hold Melody Selection 3-12 MOH or Ring Back Tone Selection 4-66 Function 1-8-07 Attendant Page-Line Key 1-8-08 Station PageLine Key Doc. No. 8283 - Release 1.
Xen IPK Features and Specifications for Xen IPK Station Transfer S-19 FEATURE DESCRIPTION Station Transfer allows any station user in the system to transfer any call to any other station. Outside calls can be transferred to Multiline Terminals without the direct line appearance. To initiate Call Transfer, press the Transfer key on a Multiline Terminal or use the hookswitch on a Single Line Telephone. The transfer is completed by going on-hook on a Multiline Terminal or Single Line Telephone.
September 2003 NEC Business Solutions Ltd SERVICE CONDITIONS General RELATED FEATURE LIST After transferring an answered call, the Multiline Terminal user can enter a conference by pressing the Conference key on the Multiline Terminal even after the Transfer key is pressed. After transferring an answered call, the Single Line Telephone user can enter a conference by providing a second hookflash.
Xen IPK Features and Specifications for Xen IPK Universal Slots U-3 FEATURE DESCRIPTION The Xen IPK system, B64-U( ) KSU, has eight universal slots and up to three cabinets can be installed for both the Basic and Expanded systems. The system uses the same KSU for the basic and expansion cabinets to support up to 24 Universal Slots. SYSTEM AVAILABILITY Terminal Type Not applicable. Required Components None. OPERATING PROCEDURES SERVICE CONDITIONS Not applicable.
September 2003 NEC Business Solutions Ltd The Basic Port Package does not limit the number of slots. It only limits the number of ports. An ESIB(8)-U( ) ETU with an ESIE(8)-U( ) ETU installed supports 16 Electronic Station Interface ports. This combination can be installed in any Interface Slot (1~8) of any Cabinet (1~3) without requiring adjacent slots to be vacant.
Xen IPK Features and Specifications for Xen IPK The available interface cards and maximum capacities for Universal Slots with the Xen IPK system are shown in the following tables.
September 2003 NEC Business Solutions Ltd Maximum Capacities Trunk Interface Units Description Basic Port Package Expanded Port Package Notes BRT (4)-U( ) ETU 4-port ISDN Interface for 8 trunks 2 8 Note 1 COI(4)-U( ) ETU 4-port CO/PBX Line Interface 4 16 Note 1 COI(8)-U( ) ETU 8-port CO/PBX Line Interface 2 8 Note 1 DID (4)-U( ) ETU 4-port Direct Inward Dialling Interface 4 18 Note 1 IPT(4)-U( ) ETU 4-port Voice over Internet Protocol Trunk Interface 4 15 Note 1, 4 IPT(8)-U(
Xen IPK Features and Specifications for Xen IPK Maximum Capacities Application Interface Units Description Basic Port Package Expanded Port Package Notes BSU(2)-U( ) ETU 2-Channel - Base Station Unit for PHS 3 8 DPH(4)-U( ) ETU 4-Channel - Door Phone Interface Unit 1 1 ECR-U( ) ETU External Control Relay Unit 1 1 MIFA-U( ) ETU Multiple Interface Unit for UCD/ACD 1 1 Note 1, 3 MIFM-U( ) ETU Multiple Interface Unit for Multifunction 1 1 Note 1, 2, 3 PBR( )-U( ) ETU 4-Channel - P
September 2003 RELATED FEATURE LIST NEC Business Solutions Ltd Feature Number Feature Name C-3 Call Arrival Keys (CAR) D-7 Digital Voice Mail D-8 Direct Inward Dialling (DID) D-16 Door/Monitor Telephone E-3 E&M Tie Lines (4-Wire) A-21 Automatic Call Distribution (ACD Plus) E-6 External Zone Paging (Meet-Me) G-1 General Purpose Relays I-7 ISDN-BRI Trunk Connections I-8 ISDN-PRI Trunk Connections L-5 Loop Start Trunks M-3 Microphone Control S-15 Station Message Detail Recording (
Programming Chapter 4 Doc. No.: 8283 - Release 1.0 September 2003 The Memory Blocks listed in this section are new or modified Memory Blocks for Xen IPK Release 1000 software.
September 2003 NEC Business Solutions Ltd 11-2-04 Call Arrival Key Block Assignment System Mode 1 Submode 1 General Description Use this Memory Block to specify the number of Call Arrival keys that can be used in the system. Data No. 04 PC Programming Display Data No.
Xen IPK Programming Programming Procedures 1 Go off-line. 2 Press LK1 + LK2 + KDto access the Memory Block. 3 Press the corresponding CO/PBX line key to change the data option. LK is green = block assigned for CAR LK is red = block not available for CAR (hardware is installed) Default Values No Call Arrival Key Blocks are assigned. Hardware equipped ports are red. Nto write the data. PressPto go back on-line. 4 Press 5 Related Programming M.B.
September 2003 NEC Business Solutions Ltd 1-13-00 PRI Channel Assignment System Mode 1 General Description This Memory Block specifies the number of channels available on each PRI ISDN line connected to the system via a PRT(1)-U( ) ETU. Submode 13 Data No. 00 Display PRT (1-8 0 1 Data No.
Xen IPK Programming 1-13-04 PRT B Channel Outgoing Priority Selection System Mode 1 Submode 13 General Description Data No. Use this Memory Block to assign the Outgoing Priority for the B-channels when calls are originated on a PRT(1)-U( ) ETU. 04 PC Programming This assignment is allowed by handset programming and MAT. + AN Display PRT (1-2) 0 1 Data No.
September 2003 NEC Business Solutions Ltd 1-13-05 PRT B Channel-to-Trunk Group Assignment System Mode 1 Submode General Description Use this Memory Block to assign a Trunk Group Number to each B channel or any Trunk Group for each B channel. Changing this assignment is not normally required and default should be set.
Xen IPK Programming 3 -12 Trunk-to-MOH Trunk Assignment System Mode 3 Submode — General Description Data No. Use this Memory Block to specify the music on hold source for each CO/PBX line. 12 PC Programming Display + BCT CO/PBX No. (01~64) Data No. 0 1 1 2 T Setting Data Title : H O L D I M E C O 0 0 D I S P L A Y Programming Procedures 1 Go off-line. 2 Press LK3 + N +AB access the Memory Block. 3 Enter data for CO/PBX No. using the dial pad to assign the music selection. .
September 2003 NEC Business Solutions Ltd 4 -50 Multiline Terminal Type Selection System Mode 4 Submode — General Description This Memory Block is used to assign a DTU-32D-1A (BK)/(WH), or DTR-32D-1A (BK)/(WH) TEL with 16 line keys or 24 line keys. Data No. 50 PC Programming Display + BTM Tel Port No. (01~99) A0~C0 0 1 Data No.
Xen IPK Programming Telephone ports A0~C0 are ports 100~120.
September 2003 NEC Business Solutions Ltd 4 - 66 MOH or Ring Back Tone Selection System Mode 4 General Description Submode Use this memory block to assign MOH or Ring Back Tone for the outside party when a trunk call is placed on hold by the Transfer key on a Multiline Terminal, hook flash from a Single Line Telephone, or the Transfer or Hold key at a PSII station. Data No. — 66 PC Programming Display Tel Port No. (01~CO) 0 1 Data No.
Xen IPK Programming Related Programming M.B. Number Memory Block Name 1-8-09 Music on Hold Pattern Selection 1-8-31 Hold Tone Source Assignment 1-8-32 Hold Internal Tone Volume Selection 3-11 CO External Source Selection 3-12 Trunk-to-MOH Trunk Assignment Doc. No.: 8283 - Release 1.0 September 2003 N Telephone Ports A0~C0 are ports 100~120.
September 2003 NEC Business Solutions Ltd 4 - 68 LCD Line Key – Name Assignment System Mode 4 General Description Submode Use this memory block to assign a name to each LCD Line Key of the DTR-16LD-1A Telephone. Up to eight characters can be assigned. Data No. — 68 Display PC Programming Data No. Tel Port (01~CO) 0 1 / Line Key 01~16 Title : L K 0 1 N A M E 0 1 > 6 8 < C O + BTT NEW Setting Data Programming Procedures 1 Go off-line. 2 Press LK4 + FH to access the Memory Block.
Xen IPK Programming LK Assign Default Note NON (not assigned) All Blank CO Outside Lines CO^xx Call Forward – Busy/No Answer CFB Call Forward – All Calls CFA Call Appearance Keys (CAP) CAPxx-yy xx=Block 00~47 yy=Key 01~24 Programmable One-Touch Keys FA xx xx=key 01~24 Trunk Group TKGP^xx xx=Trunk Group 01~32 Route Advance Group ADV^xx xx=Group 01~16 SIE including CAR SIE^xxx xxx=Port No.
September 2003 NEC Business Solutions Ltd 7-1 Card Interface Slot Assignment System Mode 7 Submode 1 General Description Use this Memory Block to specify the type of installed ETUs. Display Port Number for COI 4, TLI, DID, SLI 4, OPX, DPH, VRS, VMS 2/4 ETU Page No. Upper Slot No. 1 0 9 : N O N 1 0 1 : C O I Cabinet No. 1~3 4 — PC Programming + BS = 0 1 Port No. 1st of 4 Unit Name Lower Slot No. Data No. Port Number for COI 8, TLI, DID, ESI 8, SLI8, BRT Page No. Upper Slot No.
Xen IPK Programming 1 Go off-line. 2 Press LK7 + LK1 to access the Memory Block. 3 Use the Line key to enter setting data.
September 2003 NEC Business Solutions Ltd Page 6 Page 5 Line Key Setting Data LCD Indication Line Key Setting Data 1 ESIB(8)-U( ) ESIB8 1 NON 2 ESIE(8)-U( ) ESIB16 2 NON 3 MG(8)-U( ) MG 3 NON 4 HUB(8)-U( ) HUB 4 NON 5 NON 5 NON 6 NON 6 NON 7 NON 7 NON 8 NON 8 NON LCD Indication Page 7 Line Key Setting Data LCD Indication 1 PRT(1)-U( ) PRT4 2 PRT(1)-U( ) PRT8 3 PRT(1)-U( ) PRT12 4 PRT(1)-U( ) PRT16 5 PRT(1)-U( ) PRT20 6 PRT(1)-U( ) PRT24 7 PR
Xen IPK Programming KSU Power-Based ETU Quantity Limitations The following charts indicate the maximum number of specific ETU combinations in each KSU that are restricted by power limitations of the KSU. *NO. of ESI(8) ETUs NO. of ESI Ports Maximum NO.
September 2003 NEC Business Solutions Ltd Card Interface Slot Assignment 41 C: PORT No.
Xen IPK Programming Related Programming M.B. Number Memory Block Name 7-3-00 MIF (ACD) Assignment 7-3-01 MIF (LCR) Assignment 7-3-02 MIF (SMDR) Assignment 7-3-03 MIF (UCD) Assignment 7-3-04 MIF (Caller ID) Assignment 1-2-04 Call Arrival Key Block Assignment 1-2-21 PHS Telephone Assignment 1-2-32 IP Phone Block Assignment N 1. ETU interface cards are assigned automatically during initial power up. 2. ESI(8)-U( ) ETU with ports 01 and 02 cannot be changed. 3.
September 2003 NEC Business Solutions Ltd Doc. No.: 8283 - Release 1.