Install Guide

SENSIT SYSTEM | MANUAL
SENSIT System
11/118
2.2.3 SENSIT FLUSH MOUNT
Vehicle detection sensor for flush mount installation in the
road surface. The sensor is resistant to snow ploughs and
offers vandal resistant installation. The SENSIT Flush Mount is
featured with earth-magnetic field detection.
Operating
frequency
SENSIT FLUSH MOUNT EU: 868.2 MHz
SENSIT FLUSH MOUNT CN: 868.2 MHz
SENSIT FLUSH MOUNT US: 902-928 MHz (FHSS)
SENSIT FLUSH MOUNT AU: 915-928 MHz (FHSS)
SENSIT FLUSH MOUNT NZ : 920-925MHz (FHSS)
SENSIT FLUSH MOUNT SG : 920-925MHz (FHSS)
SENSIT FLUSH MOUNT ID: 923-925MHz (FHSS)
SENSIT FLUSH MOUNT MY : 919-923MHz (FHSS)
Detection
Magnetic Accuracy: 95%
Load resistance
Heavy traffic
Mounting
Into the floor
Weight
350 gram (12.35 oz)
Dimensions
Ø 78 mm (3.07 inch)
In the floor 72 mm (2.09 inch)
Color
Black
Detection height
0…90 cm (0 … 35.5 inch)
Protection
IP67, completely sealed housing PE
Operating
temperature
-40 ... +85°C (-40°F … +185°F)
Power supply
Built in Lithium batteries expected lifetime of 5-10
years*
Antenna
Included
* Under normal circumstances and dependent on settings.
Note
The SENSIT Flush Mount has
a vandal resistance design
but of course brute
excessive force still can
damage the device.
Warning:
Do not open-, drill in- or
puncture the enclosure.
.