CONFIGURE THE GATEWAY
1) To configure Gateway, navigate to Manual Input
2) Enter the node ID, which can be found on backside of the Gateway and
select Program Node.
3) Restart the Gateway by switching off the power for a few seconds. The app
will detect that the SENSIT Gateway is starting up and will start the
configuration sequence. The selected segment and GPS position will be
programmed and saved in the List Configured Nodes.
4) When the app shows OK, the SENSIT Gateway is ready for use.
5) Repeat this process for all Gateways. Make sure to check the segment
number before configuring the Gateways.
CONFIGURE THE RELAY NODES
1) To configure the Relay Nodes, press the yellow button of the SENSIT
Configuration Tool. During 20 seconds, the SENSIT Configuration Tool is
active (red LED blinks).
2) Move the SENSIT Configuration Tool up and down over the front surface of
the Relay Node. The Relay Node ID is detected and configuration is started
automatically. During the configuration, the GPS position is stored in the
app and the node segment is set.
3) After OK is indicated, the Relay node is ready for use.
4) Repeat this process for all Relay Nodes. Make sure to check the segment
number before configuring the Relay Nodes
CONFIGURE SENSIT
1) To configure the SENSIT sensors, start with the sensor in the first parking
bay on the map in the SIS.
2) Press the yellow button of the SENSIT Configuration Tool. During 20
seconds, the SENSIT Configuration Tool is active (red LED blinks).
3) Rotate the SENSIT Configuration Tool over the surface of the sensor.
4) The SENSIT is activated and the ID number will appear in the app. The ID
number and GPS coordinate are stored in the app and the sensor
calibration is started.
5) When the display indicates OK, the sensor is ready for use.
6) Repeat this process for all SENSIT sensors by following the bay numbers
sequentially. Make sure to check the segment number before configuring
the SENSIT sensors.
SIS SOFTWARE
After configuring the SENSIT components, the stored app data must be transmitted
to the SIS Software. Therefore go to ‘list configured nodes’, check the list and select
‘Export’. Select the media of your choice and send the data. The message contains a
file in CSV format which can be loaded into the SIS software.